logo
Gefunden 215 Produkte für "

armoured power cable

"
Qualität PVC-isolierter Stromkabel Stahlband Draht Panzer PVC-Schicht elektrischer Stromkabel Fabrik

PVC-isolierter Stromkabel Stahlband Draht Panzer PVC-Schicht elektrischer Stromkabel

PVC Insulated Power Cable Steel Tape Wire Armoured PVC Sheathed Electrical Power Wire APPLICATION This product is suitable for rated voltage not exceeding 0.6/1kV . In the line, for transmission and distribution of energy. CONSTRUCTION Conductor: Class 1/ Class 2 stranded Copper conductor Insulation: Polyvinyl chloride (PVC) Filler ( options) : Polypropylene mesh tearing rope I nner sheath: Polyvinyl chloride (PVC) A rmour: Stainless steel tape( single core ) galvanized steel

Qualität MV Steel Wire Armoured Cable CU/XLPE/CTS/STA/PVC Flame-retardant Power Cable Fabrik

MV Steel Wire Armoured Cable CU/XLPE/CTS/STA/PVC Flame-retardant Power Cable

MV Steel Wire Armoured Cable CU/XLPE/CTS/STA/PVC Flame-retardant Power Cable APPLICATION Industrial & Utility Power Distribution‌ Underground & Trench Laying‌ Flame-Retardant Environments‌ High-Temperature & Corrosive Conditions‌ Medium-Voltage Networks (Up to 35kV)‌ CONSUCTRUCTION Conductor: Compacted conductors Conductor Shield: Semi conductive shielding material (below 500mm 2 ) Semi conductive tape+semi conductive shielding material (500 mm 2 and above) Insulation:

Qualität IEC 60502-2 XLPE Isoliertes Aluminium-Pantall 3X300mm 3X150mm Flammschutznetzkabel Fabrik

IEC 60502-2 XLPE Isoliertes Aluminium-Pantall 3X300mm 3X150mm Flammschutznetzkabel

IEC 60502-2 XLPE Insulated Aluminium Armoured 3X300mm 3X150mm Flame Retardant Power Cable Applications The cables arewidely used in places such as wind farms and solar power stations to meet the power transmission needs of these places ‌ Main Technical Properties 1. DC resistance of conductor at 20°C : not exceed ing 0.1 Ω/km; 2. 4h Power Frequency Voltage Test (4U₀) : No breakdown occurred; 3. 50Hz AC Withstand Voltage Test: 65 kV for 30 min ; No breakdown occurred; 4.

Qualität 3.6/6kV26/35kV Mittelspannungskabel XLPE Isolierband Fabrik

3.6/6kV26/35kV Mittelspannungskabel XLPE Isolierband

3.6/6kV~26/35kV Medium Voltage Cable XLPE Insulation PVC Sheath Metal Tape Armouring Power Cable Application Suitable for urban underground power grids, power station outgoing lines, internal power supply lines of industrial and mining enterprises, etc. CONSTRUCTION Conductor: Round compacted conductors Conductor Shield: Semi conductive shielding material (below 500mm Semi conductive tape+semi conductive shielding material (500 mm 2 and above) Insulation: Polyvinyl chloride

Qualität YJLHV62 YJLHV22-18/30kV-Luminiumlegierung Leiter XLPE Isolierung PVC-Hülle Metallband Panzerung Stromkabel Fabrik

YJLHV62 YJLHV22-18/30kV-Luminiumlegierung Leiter XLPE Isolierung PVC-Hülle Metallband Panzerung Stromkabel

YJLHV62 YJLHV22-18/30kV luminium Alloy Conductor XLPE Insulation PVC Sheath Metal Tape Armouring Power Cable Application The AA-8000 series aluminum alloy cables (e.g., AA-8030, AA-8176) are widely used in electrical systems due to their lightweight, cost-efficiency, and superior mechanical/electrical performance compared to pure aluminum. 1. Power Distribution Building Wiring: Branch circuits, feeders, and service entrance cables (NEC Article 310 compliant). Utility Grids:

Qualität AWA Aluminiumdraht gepanzerte, flammhemmende Netzkabel CU/XLPE/CTS/AWA Fabrik

AWA Aluminiumdraht gepanzerte, flammhemmende Netzkabel CU/XLPE/CTS/AWA

AWA Aluminium Wire Armored Flame-retardant Power Cable CU/XLPE/CTS/AWA APPLICATION Industrial Power Networks‌: Suitable for factories, mining sites, and heavy machinery due to its armored design (AWA) and flame-retardant properties‌ Commercial Buildings‌: Ensures safe power transmission in shopping malls, hospitals, and high-rises, where fire safety is critical‌ Harsh Environments‌: Resists physical damage and moisture, making it ideal for outdoor installations or areas with

Qualität MV AWA Panzerkabel 3.6/6kV26/35kV AL/XLPE/AWA/SWA/LSZH angepasste Länge Fabrik

MV AWA Panzerkabel 3.6/6kV26/35kV AL/XLPE/AWA/SWA/LSZH angepasste Länge

MV AWA Armoured Electrical Cable 3.6/6kV~26/35kV AL/XLPE/AWA/ SWA/LSZH Customized Length APPLICATION Widely used in industrial power grids, energy infrastructure, underground substations, and cross-border power engineering projects CONSTRUCTION Conductor : Aluminium Insulation :XLPE Filler : LSZH Armour :Single core: AWA (Aluminium wire armour) All other sizes: SWA (Galvanized round steel wire) Sheath : LSZH STANDARD EN 60502-2 CHARACTERISTICS Voltage Rating Uo/U: 3. 8 /6 .6

Qualität 26/35kV AWA-Pantarkabel CU/XLPE/AWA/PVC/PE-Flammhemmungs-Stromkabel mit Umhüllung Fabrik

26/35kV AWA-Pantarkabel CU/XLPE/AWA/PVC/PE-Flammhemmungs-Stromkabel mit Umhüllung

26/35kV AWA Armoured Cable CU/XLPE/AWA/PVC/PE Sheathed Flame-retardant Power Cable Application The 26/35kV AWA (Aluminium Wire Armoured) copper conductor power cable is designed for medium voltage power transmission and distribution systems up to 35kV. It is widely used in applications requiring high reliability, mechanical protection, and fire safety performance. Main Construction Conductor: Compacted conductors Insulation: PVC Metal Screen: Copper Tape Armouring: Aluminium

Qualität Aluminiumlegierung Leiter Stromkabel XLPE Isolierung PVC Hülle Metallband Rüstung Fabrik

Aluminiumlegierung Leiter Stromkabel XLPE Isolierung PVC Hülle Metallband Rüstung

Aluminium Alloy Conductor Cable XLPE Insulation PVC Sheath Metal Tape Armouring Power Cable Application Aluminum alloy cables are widely utilized in various industries due to their lightweight, cost-effectiveness, corrosion resistance, and excellent electrical conductivity. Construction Conductor: AA-8000 Series AL-Alloy Conductor Shield Insulation Binder Tape Outer sheath: PVC Specification YJLHV62 YJLHV22-18/30kV C able S tructure P arameters Specs mm² Conductor diameter mm