| Menşe yeri: | Hebei, Çin |
|---|---|
| Marka adı: | rubber cable |
| Sertifika: | CCC,ISO,TUV,CE, EAC |
| Model numarası: | H07RN-F |
| Min sipariş miktarı: | Pazarlık edilebilir |
| Fiyat: | pazarlık edilebilir |
| Ambalaj bilgileri: | Rulolar, ahşap davullar, çelik davullar, makaralar veya özelleştirilmiş |
| Teslim süresi: | Farklı Adete göre 7-30 gün |
| Ödeme koşulları: | L/C,T/T,Western Union |
| Yetenek temini: | 100km/hafta |
| Ceket: | Lastik | Sıklık: | 50 Hz |
|---|---|---|---|
| Yangındaki Davranış: | IEC 60332-1 | Bakır: | Kalaylı Bakır |
| Diğer Çekirdek: | 2 Çekirdek, 3 Çekirdek, 4 Çekirdek, 5 Çekirdek | Özelleştirme: | Mevcut |
H07RN-F Rubber Cable | Heavy-Duty Flexible Power Cable 450/750V
Product Overview
The H07RN-F rubber cable is a heavy-duty flexible power cable designed for demanding industrial and outdoor applications. Recognized across Europe and internationally, this HAR-approved cable features a Class 5 flexible copper conductor, EPR (Ethylene Propylene Rubber) insulation, and a tough PCP (Polychloroprene) rubber outer sheath .
Rated at 450/750V, the H07RN-F cable is engineered to withstand weather, oil/grease, mechanical stress, and thermal variations, making it the go-to choice for mobile power supplies, construction sites, industrial equipment, and even underwater installations .
Key Features
| Feature | Benefit |
|---|---|
| Class 5 flexible copper conductor | Excellent flexibility for frequent movement and tight installations |
| EPR insulation (Type EI4) | High dielectric strength, excellent thermal and aging resistance |
| PCP rubber outer sheath (Type EM2) | Outstanding resistance to oil, weather, ozone, and abrasion |
| 450/750V rated voltage | Suitable for heavy-duty industrial power applications |
| Wide temperature range | -40°C to +90°C (flexible use); up to +85°C for fixed protected installations |
| Flame retardant | Self-extinguishing per IEC/EN 60332-1-2 |
| Water resistant (AD8 rating) | Suitable for permanent immersion up to 100m depth |
| UV and ozone resistant | Ideal for long-term outdoor exposure |
| HAR certification | Harmonized European standard, widely accepted across Europe |
Applications
The H07RN-F rubber cable is the industry standard for heavy-duty flexible power connections.
1. Industrial & Manufacturing
Mobile power supplies and portable equipment
Machine tools, handling equipment, and hoisting devices
Motor connection cables (up to 1000V with built-in protection)
Workshops and production lines
2. Construction & Site Work
Temporary power supply on construction sites
Electric tools (drills, circular saws, heating plates)
Portable generators and lighting towers
3. Outdoor & Agricultural
Agricultural machinery and equipment
Irrigation systems and pumps
Stage and audio-visual equipment
4. Harsh & Hazardous Environments
Explosive areas (ATEX-compliant with local regulations)
Port areas, docks, and dams
Refrigerated environments and cold storage
5. Underwater & Wet Locations
Submersible pumps (sewage, drainage, well pumps)
Marine and offshore applications
Swimming pool equipment and fountains
6. Fixed Installations
Protected fixed installation in pipes or units up to 1000V
On-plaster installation in temporary buildings
*For extremely low temperatures down to -40°C or high-temperature industrial ovens, the enhanced H07RN-F (full 90°C rating) is recommended* .
Construction Details
| Layer | Material | Standard |
| Conductor | Bare copper, finely stranded | IEC 60228 Class 5 |
| Insulation | EPDM rubber (Ethylene Propylene Rubber) – Type EI4 | EN 50363-1 |
| Core Identification (2-5 cores) | Colored per VDE 0293-308 (e.g., 3-core: GNYE + Blue + Brown) | |
| Core Identification (6+ cores) | Black cores with white numerals | |
| Stranding | Cores stranded in layers with optimal lay lengths | |
| Seating/Inner Bedding | Rubber or plastic intermediate layer between insulation and sheath | |
| Outer Sheath | PCP rubber (Polychloroprene / Neoprene) – Type EM2 | EN 50363-2-1 |
| Sheath Color | Black (standard) – RAL 9005 |
Electrical Characteristics
| Parameter | Value |
|---|---|
| Rated Voltage (U₀/U) | 450/750V AC |
| Maximum Operating Voltage (AC) | 476V between conductor/earth; 825V between conductors |
| Maximum Operating Voltage (DC) | 619V conductor/earth; 1238V conductor/conductor |
| Test Voltage | 2500V AC (core/core) |
| Current Carrying Capacity | According to DIN VDE 0298-4 |
| Insulation Resistance | > 1 GΩ × cm |
Thermal Characteristics
| Parameter | Value |
|---|---|
| Conductor Operating Temperature (Flexible Use) | +60°C (standard) to +90°C (enhanced version) |
| Conductor Operating Temperature (Fixed Protected) | +85°C |
| Short Circuit Temperature | +200°C (max) |
| Ambient Temperature (Flexible Installation) | -25°C to +60°C (standard); -40°C to +90°C (enhanced) |
| Ambient Temperature (Fixed Installation) | -30°C to +60°C (standard); -50°C to +90°C (enhanced) |
Chemical & Environmental Properties
| Property | Performance | Test Standard |
|---|---|---|
| Oil Resistance | Yes | IEC 60811-404 |
| Flame Retardancy | Self-extinguishing | IEC 60332-1-2 |
| UV Resistance | Excellent | — |
| Ozone Resistance | Yes | — |
| Weather Resistance | Very good | — |
| Water Resistance | AD8 – permanent immersion up to 100m | |
| Halogen Free | Enhanced version available (LSOH) |
Standards & Certifications
| Standard/Certification | Description |
|---|---|
| EN 50525-2-21 | European harmonized standard for rubber cables |
| HD 22.4 / HD 516 | Harmonization documents |
| IEC 60245-4 | International standard (Type 66) |
| DIN VDE 0285-525-2-21 | German standard |
| ◁HAR▷ | Harmonized European approval – widely accepted across Europe |
| CE | Conforms with Low-Voltage Directive 2014/35/EU |
| RoHS | Compliant |
| EAC | Eurasian Conformity |
Common Cross-sections
| Cross-section (mm²) | Approx. AWG | Standard Applications |
|---|---|---|
| 1.5mm² | 16 | Small power tools, hand lamps |
| 2.5mm² | 14 | Electric tools, portable equipment |
| 4mm² | 12 | Industrial machinery |
| 6mm² | 10 | Motor connections |
| 10mm² | 8 | Heavy equipment |
| 16mm² – 70mm² | 6 – 2/0 | Main power supply, large machinery |
| 95mm² – 400mm² | 4/0 – 800 MCM | High-current industrial applications |
Comparison: H07RN-F vs Other Rubber Cables
| Feature | H07RN-F | H05RN-F | H07ZZ-F (LSZH) |
|---|---|---|---|
| Voltage Rating | 450/750V | 300/500V | 450/750V |
| Temperature Rating | -40°C to +90°C | -25°C to +60°C | -40°C to +90°C |
| Halogen Free | Enhanced version only | No | Yes (LSOH) |
| Oil Resistance | Yes | Limited | Yes |
| Typical Applications | Heavy industrial, construction, outdoor | Light duty, household appliances | Public buildings, mass transit |
| Sheath Material | PCP (Neoprene) | Rubber | LSZH compound |
| Water Immersion | Up to 100m (AD8) | Limited | Limited |
Installation & Handling Guidelines
Pre-installation
Inspect the cable for any visible damage to the rubber sheath
Avoid dragging on sharp edges – protect the cable during pulling
Use proper cable grips – never pull by the sheath alone
Temperature Considerations
Minimum installation temperature: -25°C (standard version)
For temperatures below -25°C, use the enhanced version rated to -40°C
Pre-heat the cable if ambient temperature is extremely low to prevent sheath cracking
Termination
Use appropriate connectors for fine-stranded Class 5 conductors
Avoid screw terminals without pin terminals – use open-type lugs or pin ferrule
Follow torque specifications to prevent loosening from vibration
Testing After Installation
Insulation resistance test – measure between cores and between core/earth
Continuity test – verify protective conductor integrity (GNYE core)
High voltage test – 2500V AC for 5 minutes (per EN 50525-2-21)
Why Choose Our H07RN-F Cable?
| Advantage | Description |
|---|---|
| Certified Quality | ◁HAR▷ approved, CE marked, RoHS compliant |
| Heavy-duty Construction | PCP rubber sheath for maximum durability |
| Enhanced Temperature Range | -40°C to +90°C – superior to standard rubber cables |
| AD8 Water Resistance | Suitable for permanent submersion up to 100m |
| Oil, UV, Ozone Resistant | Withstands the harshest environments |
| Flame Retardant | Self-extinguishing per IEC 60332-1-2 |
| Full Size Range | Available from 1.5mm² to 400mm², 2 to 5 cores |
| Free Samples | Available (shipping cost only) |
| 12-month Warranty | Against manufacturing defects |
| OEM/ODM Support | Custom printing, packaging, labeling |
| Global Shipping | Experienced in export logistics worldwide |
Frequently Asked Questions (FAQ)
Q: What does H07RN-F stand for?
A: H = Harmonized type, 07 = 450/750V voltage rating, R = Rubber insulation (EPR), N = Polychloroprene rubber sheath (PCP/Neoprene), F = Fine-stranded flexible conductor (Class 5) .
Q: What is the difference between H07RN-F and H05RN-F?
A: H07RN-F is rated at 450/750V for heavy industrial use, while H05RN-F is rated at 300/500V for light-duty household applications.
Q: What is the maximum operating temperature?
A: Standard H07RN-F: +60°C (flexible use) / +85°C (fixed protected). Enhanced version: +90°C for both flexible and fixed use .
Q: Can H07RN-F be used underwater?
A: Yes. Enhanced versions are rated AD8 approved – suitable for permanent immersion up to 100m water depth .
Q: Is H07RN-F halogen-free?
A: Standard H07RN-F uses PCP rubber, which is not halogen-free. Halogen-free LSOH enhanced versions are available for applications requiring low smoke and zero halogen .
Q: Is this cable oil-resistant?
A: Yes, H07RN-F is certified oil-resistant per IEC 60811-404 .
Q: Is H07RN-F UV resistant for outdoor use?
A: Yes, the black PCP rubber sheath is UV and ozone resistant, making it ideal for permanent outdoor exposure .
Q: What does "G" in H07RN-F 5G6 mean?
A: "G" indicates the cable includes a Green/Yellow protective conductor (earth wire). "X" indicates no protective conductor .
Q: What is HAR certification?
A: HAR (Harmonized) certification is a European approval mark indicating the cable meets all harmonized standards and is accepted across CENELEC member countries .
Q: Do you provide free samples?
A: Yes, we provide free samples of H07RN-F cable. The customer is only responsible for the shipping cost.
A: Yes, we support OEM/ODM orders including custom printing (project name, customer logo, sequential metering).
Q: What is the typical lead time?
A: Typical lead time is 10–20 days after deposit confirmation, depending on order quantity and conductor size.
![]()
![]()
![]()
Genel Değerlendirme
Derecelendirme Anlık Görüntüsü
Aşağıdaki tüm oyların dağılımıdırTüm Yorumlar