logo
products

Armored Aluminium Conductor Cable AL/XLPE/STA SWA/PVC NA2XRY NA2X2Y

Temel bilgi
Menşe yeri: Hebei, Çin
Marka adı: Zhongdong
Sertifika: IEC,CE,ISO,TUV
Min sipariş miktarı: Pazarlık edilebilir
Fiyat: pazarlık edilebilir
Ambalaj bilgileri: Rulolar, ahşap davullar, çelik davullar, makaralar veya özelleştirilmiş
Teslim süresi: Farklı Adete göre 7-30 gün
Ödeme koşulları: , L/c, t/t
Yetenek temini: 100km/hafta
Detay Bilgi
Gerilim: 26/35KV Yalıtım: XLPE
Ceket: PVC Çekirdek yok: 1,3
Zırhlama: Çelik Bant veya Çelik Tel Şef: Alüminyum

Ürün Açıklaması

Armored Aluminium Conductor Cable AL/XLPE/STA SWA/PVC NA2XRY NA2X2Y


APPLICATION

  • Substation connections
  • Urban underground grids
  • Mining and heavy industrial power distribution

CONSUCTRUCTION

Conductor:Class 2 Aluminium conductor 

Conductor :Semi-conductive shield 

Insulation:Cross-Linked Polyethylene(XLPE) 

Insulation shield:Semi-conductive shield 

Binder tape: Non-woven fabrics: 

Isolation sleeve: Polyvinyl chloride(PVC) 

Armour:Non-magnetic steel Tape or Steel Wire

Outer sheath:Polyvinyl chloride (PVC)


Armored Aluminium Conductor Cable AL/XLPE/STA SWA/PVC NA2XRY NA2X2Y 0Armored Aluminium Conductor Cable AL/XLPE/STA SWA/PVC NA2XRY NA2X2Y 1



CHARACTERISTIC 

Voltage Rating Uo/U

26/35(40.5)kV 

Temperature Rating

Maximum operating temperature of conductor:+90℃

Operating ambient temperature: -15℃~+55

Cable laying temperature:Not less than 0℃(When the ambient temperature is below 0℃, the cable should be preheated.) 

Minimum Bending Radius

Single Core 15D

(D is the actual outer diameter of the cable)


SPECIFICATION


26/35kV


Specs

Conductor diameter

Outer thickness of insulation

Approx outer diameter of cable

Approx cable weight

 

Specs

Conductor diameter

Outer thickness of insulation

Approx outer diameter of cable

Approx cable weight

mm²

mm

±1.0mm

mm

kg/km

mm²

mm

±1.0mm

mm

kg/km

1×50

7.6±0.2

312

44.1

3697

3×50

7.6±0.2

31.2

85.5

10922

1×70

9.2±0.2

32.8

45.8

4073

3×70

9.2±0.2

32.8

89.3

12127

1×95

10.9±0.2

34.5

47.5

4481

3×95

10.9±0.2

34.5

93.3

13610

1×120

12.2±0.2

35.8

49.0

4874

3×120

12.2±0.2

35.8

96.5

14791

1×150

13.6±0.2

37.2

50.6

5299

3×150

13.6±0.2

37.2

99.9

16179

1×185

15.2±0.2

38.8

52.3

5778

3×185

15.2±0.2

38.8

103.5

17856

1×240

17.4±0.2

41.0

54.5

6530

3×240

17.4±0.2

41.0

108.7

20327

1×300

19.5±0.2

43.1

57.0

7360

3×300

19.5±0.2

43.1

115.3

24487

1×400

22.0±0.2

45.6

59.7

8363

3×400

22.0±0.2

45.6

121.4

27921

1×500/35

24.8±0.2

492

66.0

10213

3×500/35

24.8±0.2

49.2

134.8

34088

1×630/35

28.2±0.2

52.6

69.7

11899

3×630/35

28.2±0.2

52.6

1,448

42268

1×800/35

33.7±0.2

58.1

76.8

15129

 

 

 

 



CONTACTR US FOR MORE VOLATAGE


ABOUT US

Armored Aluminium Conductor Cable AL/XLPE/STA SWA/PVC NA2XRY NA2X2Y 2


APPLICATION

Armored Aluminium Conductor Cable AL/XLPE/STA SWA/PVC NA2XRY NA2X2Y 3


WHY CHOOSE US

Armored Aluminium Conductor Cable AL/XLPE/STA SWA/PVC NA2XRY NA2X2Y 4


PARTNER

Armored Aluminium Conductor Cable AL/XLPE/STA SWA/PVC NA2XRY NA2X2Y 5Armored Aluminium Conductor Cable AL/XLPE/STA SWA/PVC NA2XRY NA2X2Y 6


FAQ

1.What is the core material of this cable?‌
The conductor is made of aluminium (AL), which offers a lightweight and cost-effective alternative to copper while maintaining good conductivity.

2.What does XLPE stand for in the cable's insulation?‌
XLPE stands for cross-linked polyethylene, providing excellent thermal resistance, durability, and protection against environmental factors like moisture and chemicals.
3. What does STA SWA signify in the cable structure?‌
STA SWA refers to steel tape armour (SWA) with a smooth or corrugated design, offering mechanical protection against crushing forces and rodent damage.
4. What is the outer sheath material (PVC) used for?‌
The PVC sheath provides additional insulation, weather resistance, and durability, making it suitable for outdoor and harsh environments.

5. What are the key applications of this cable?‌
It is commonly used in industrial settings, power distribution networks, and underground installations where robustness and conductivity are critical.
6.How does aluminium compare to copper in this cable?‌
Aluminium is lighter and more economical than copper, though it may have slightly higher resistance; it is ideal for large-scale power transmission.

7. What safety features does the XLPE insulation provide?‌
XLPE insulation ensures high-temperature stability, reducing risks of short circuits and fire hazards, even under heavy loads.

8. Why is steel tape armour (SWA) included in the design?‌
SWA protects the cable from physical damage, moisture ingress, and electromagnetic interference, ensuring longevity in challenging conditions.

9. What environmental conditions is this cable suitable for?‌
It is designed for both indoor and outdoor use, withstanding UV exposure, moisture, and temperature variations, thanks to its PVC sheath and XLPE insulation.

10. What are the advantages of using this cable over non-armoured alternatives?‌
The armour layer (STA SWA) significantly enhances mechanical strength, making it more reliable for buried or exposed installations where external threats are present.

İletişim bilgileri
Cai

Telefon numarası : +8618991159926

Whatsapp : +8619829885532