pvc power cable
"
Подземный кабель проводника из алюминиевого сплава серии AA-8000
Underground Aluminum Alloy Conductor Cable AA-8000 Series YJLHV62 YJLHV22 Application The YJLHV62 YJLHV22 cable is an aluminum alloy conductor power cable designed for medium-voltage applications, combining durability, flexibility, and environmental resilience. Below is a detailed description: Construction Conductor{ Round compacted conductors Conductor Shield: Semi conductive shielding material (below 500mm) Semi conductive tape+semi conductive shielding material (500 mm
Алюминиевый кабель 1000 кмил со 100% изоляцией из СПЭ 25 кВ для промышленных или инфраструктурных нагрузок
1000kcmil Aluminium Cable 100% XLPE Insulated 25kV for Industrial or Infrastructure Loads Applications The cable is designed for medium-voltage primary distribution systems, suitable for heavy industrial loads and infrastructure projects requiring reliable high-capacity power transmission. Construction 1. Conductor: copper or aluminum. 2. Provide armored and unarmoured power cables. 3. Rated voltage Medium voltage: 6kV (um=7.2kv) -30kv (um=36kv) 4. PVC or polyethylene sheath.
Гибкий медный проводник резиновый изоляционный кабель 300/500V IEC 60245 57 резиновый кабель
Flexible Copper Conductor Rubber Insulated Cable 300/500V IEC 60245 57 Rubber Cable APPLICATION Z and YZW medium-duty rubber-sheathed flexible cables are widely used in various mobile electrical equipment and tools with an AC rated voltage of 300/500V. Their primary applications include: Household appliances: Power supply for portable devices like electric kettles, vacuum cleaners, and power tools. Industrial equipment: Connection cables for small machinery, pumps, and
Кабель огнестойкий низковольтный 0,6/1 кВ с медным проводником и изоляцией из сшитого полиэтилена для противопожарных систем
Low Voltage Fire Rated Cable 0.6/1kV CU/XLPE/PE YJY N2X2Y This fire-resistant cable is designed for low-voltage power distribution systems where fire safety is critical, rated for 0.6/1kV applications. Applications Suitable for installation in cable ducts, underground applications, and exposed installations in various industrial and commercial environments. Construction Details Conductor: Class 1/Class 2 stranded copper conductor Refractory layer: Single-sided gold mica tape
Кабель огнестойкий низковольтный 0,6/1 кВ с медным проводником и изоляцией из сшитого полиэтилена для противопожарных систем
Low Voltage Fire Rated Cable 0.6/1kV CU/XLPE/PE YJY N2X2Y This fire-resistant cable is designed for low-voltage power distribution systems where fire safety is critical, rated for 0.6/1kV applications. Applications Suitable for installation in cable ducts, underground applications, and exposed installations in various industrial and commercial environments. Construction Details Conductor: Class 1/Class 2 stranded copper conductor Refractory layer: Single-sided gold mica tape
Ультрафиолетоустойчивые кабели средней напряженности с алюминиевым проводником для распределительных сетей 12/20 кВ
UV Resistant Medium Voltage Cables with Aluminoum Conductor for Distribution Networks 12/20kV Application This type of cable is primarily used for power transmission and distribution in medium-voltage power systems, making it suitable for urban grids, industrial and mining enterprises, and infrastructure projects where high power supply reliability is required. Construction Conductor: Class 2 Aluminium conductor Conductor: Semi-conductive material Insulation:XLPE Insulation
110 кВ XLPE Изолированный медный кабель 630 мм2 с сварной гофрированной алюминиевой оболочкой
Этот медный кабель сечением 630 мм² с изоляцией из сшитого полиэтилена, предназначенный для подземной передачи напряжения 110 кВ, имеет сварную гофрированную алюминиевую оболочку, обеспечивающую 100% водонепроницаемость при прямом прокладке. Соответствует стандарту IEC 60840, идеально подходит для подстанций, подземных городских сетей и тяжелой промышленности. Поддерживается сторонняя FAT.
35 кВ 1 ядро кабель среднего напряжения XLPE изолированный 1x185 1x300 MV бронированный кабель
35KV Single Core Medium Voltage Cable XLPE Insulated 1x185 1x300 Construction 1. Conductor- aluminum or copper multiwire circular compacted . 2. Conductor screen - extruded of conductive peroxide cross-linked PE. 3.Insulation - peroxide cross-linked PE. 4. Insulation screen - extruded of conductive peroxide cross-linked PE. 5.Combined screen: 5.1 A layer of conductive paper tapes or conductive polymer tape with minimum thickness of 0.2 mm. 5.2. A layer of copper wires with a
Соединительные кабели для солнечных панелей с двумя ядрами H1z2z2-K PV1-F
Twin Core Solar Cable H1z2z2-K PV1-F PV Wire Application Solar cables applies to low smoke halogen-free, flexible, single-core power cables with cross linked insulation and sheath. In particular for use at the direct current (d.c.) side of photovoltaic systems, with a nominal d.c. voltage of 1.5 kV between conductors and between conductor and earth. The cables are suitable to be used with Class II equipment. The cables are designed to operate at a normal maximum conductor