logo
발견 389 제품 "

pvc power cable

"
품질 지하 알루미늄 합금 선도 케이블 AA-8000 시리즈 사용자 정의 길이 공장

지하 알루미늄 합금 선도 케이블 AA-8000 시리즈 사용자 정의 길이

Underground Aluminum Alloy Conductor Cable AA-8000 Series YJLHV62 YJLHV22 Application The ‌ YJLHV62 YJLHV22 cable ‌ is an aluminum alloy conductor power cable designed for medium-voltage applications, combining durability, flexibility, and environmental resilience. Below is a detailed description: Construction Conductor{ Round compacted conductors Conductor Shield: Semi conductive shielding material (below 500mm) Semi conductive tape+semi conductive shielding material (500 mm

품질 1000kcmil 알루미늄 케이블 100% XLPE 절연 25kV 산업 또는 기반 시설 부하용 공장

1000kcmil 알루미늄 케이블 100% XLPE 절연 25kV 산업 또는 기반 시설 부하용

1000kcmil Aluminium Cable 100% XLPE Insulated 25kV for Industrial or Infrastructure Loads Applications The cable is designed for medium-voltage primary distribution systems, suitable for heavy industrial loads and infrastructure projects requiring reliable high-capacity power transmission. Construction 1. Conductor: copper or aluminum. 2. Provide armored and unarmoured power cables. 3. Rated voltage Medium voltage: 6kV (um=7.2kv) -30kv (um=36kv) 4. PVC or polyethylene sheath.

품질 유연성 구리 도체 고무 절연 케이블 300/500V IEC 60245 57 고무 케이블 공장

유연성 구리 도체 고무 절연 케이블 300/500V IEC 60245 57 고무 케이블

Flexible Copper Conductor Rubber Insulated Cable 300/500V IEC 60245 57 Rubber Cable APPLICATION Z and YZW medium-duty rubber-sheathed flexible cables are widely used in various mobile electrical equipment and tools with an AC rated voltage of 300/500V. Their primary applications include: Household appliances: Power supply for portable devices like electric kettles, vacuum cleaners, and power tools. Industrial equipment: Connection cables for small machinery, pumps, and

품질 구리 도체 및 XLPE 절연을 사용한 0.6/1kV 저전압 내화 케이블 (화재 안전 적용) 공장

구리 도체 및 XLPE 절연을 사용한 0.6/1kV 저전압 내화 케이블 (화재 안전 적용)

Low Voltage Fire Rated Cable 0.6/1kV CU/XLPE/PE YJY N2X2Y This fire-resistant cable is designed for low-voltage power distribution systems where fire safety is critical, rated for 0.6/1kV applications. Applications Suitable for installation in cable ducts, underground applications, and exposed installations in various industrial and commercial environments. Construction Details Conductor: Class 1/Class 2 stranded copper conductor Refractory layer: Single-sided gold mica tape

품질 구리 도체 및 XLPE 절연을 사용한 0.6/1kV 저전압 내화 케이블 (화재 안전 적용) 공장

구리 도체 및 XLPE 절연을 사용한 0.6/1kV 저전압 내화 케이블 (화재 안전 적용)

Low Voltage Fire Rated Cable 0.6/1kV CU/XLPE/PE YJY N2X2Y This fire-resistant cable is designed for low-voltage power distribution systems where fire safety is critical, rated for 0.6/1kV applications. Applications Suitable for installation in cable ducts, underground applications, and exposed installations in various industrial and commercial environments. Construction Details Conductor: Class 1/Class 2 stranded copper conductor Refractory layer: Single-sided gold mica tape

품질 배전망용 알루미늄 도체 내자외선 중간 전압 케이블 12/20kV 공장

배전망용 알루미늄 도체 내자외선 중간 전압 케이블 12/20kV

UV Resistant Medium Voltage Cables with Aluminoum Conductor for Distribution Networks 12/20kV Application This type of cable is primarily used for power transmission and distribution in medium-voltage power systems, making it suitable for urban grids, industrial and mining enterprises, and infrastructure projects where high power supply reliability is required. Construction Conductor: Class 2 Aluminium conductor Conductor: Semi-conductive material Insulation:XLPE Insulation

품질 용접된 골판지 알루미늄 외장을 갖춘 110kV XLPE 절연 630mm² 구리 케이블 공장

용접된 골판지 알루미늄 외장을 갖춘 110kV XLPE 절연 630mm² 구리 케이블

110kV 지하 전송용으로 설계된 이 XLPE 절연 630mm² 구리 케이블은 100% 방수 직접 매설을 위한 용접된 주름진 알루미늄 외피를 특징으로 합니다. IEC 60840 규격을 준수하며 변전소, 도시 전력망 지하화 및 중공업에 이상적입니다. 타사 FAT가 지원됩니다.

품질 35KV 1 코어 중전압 케이블 XLPE 단열 1x185 1x300 MV 장갑 케이블 공장

35KV 1 코어 중전압 케이블 XLPE 단열 1x185 1x300 MV 장갑 케이블

35KV Single Core Medium Voltage Cable XLPE Insulated 1x185 1x300 Construction 1. Conductor- aluminum or copper multiwire circular compacted . 2. Conductor screen - extruded of conductive peroxide cross-linked PE. 3.Insulation - peroxide cross-linked PE. 4. Insulation screen - extruded of conductive peroxide cross-linked PE. 5.Combined screen: 5.1 A layer of conductive paper tapes or conductive polymer tape with minimum thickness of 0.2 mm. 5.2. A layer of copper wires with a

품질 쌍핵 태양 전지 패널 연결 케이블 H1z2z2-K PV1-F PV 와이어 열 저항 공장

쌍핵 태양 전지 패널 연결 케이블 H1z2z2-K PV1-F PV 와이어 열 저항

Twin Core Solar Cable H1z2z2-K PV1-F PV Wire Application Solar cables applies to low smoke halogen-free, flexible, single-core power cables with cross linked insulation and sheath. In particular for use at the direct current (d.c.) side of photovoltaic systems, with a nominal d.c. voltage of 1.5 kV between conductors and between conductor and earth. The cables are suitable to be used with Class II equipment. The cables are designed to operate at a normal maximum conductor