xlpe power cable
"
Cabo de alimentação MT de 3 núcleos de 6kV a 35kV, cabo blindado de média tensão
6kV to 35kV 3-Core MV Power Cable, Armored Medium Voltage Cable APPLICATION Medium voltage 3-core cables (typically rated from 6 kV to 36 kV) are widely used in power distribution networks due to their balanced phase loading, compact design, and enhanced reliability compared to single-core alternatives. Urban & Industrial Distribution:Deployed in substations, factories, and commercial complexes to transmit power with reduced electromagnetic interference (EMI). Preferred for
Cabo de alimentação de baixa tensão 0,6/1kV de três condutores 1,5mm2 a 400mm2 Cabo certificado EAC
Three Core 0.6/1kV Low voltage Power Cable 1.5mm2 to 400mm2 EAC Certified Cable APPLICATION Three Core 0.6/1kV Low Voltage Power Cable with EAC certification is designed for: Underground installations in commercial/residential power distribution systems, utilizing durable PVC/XLPE insulation for environmental protection Industrial applications such as construction sites and power stations, where armored variants (e.g., SWA) provide mechanical strength Low-voltage networks
6.3/ 11 kV Cabo de Voltagem Média Armadura AWA
6.3/ 11kV Medium Voltage Cable Aluminium Wire AWA Armoured Flame-retardant Power Cable APPLICATION 6.3/11kV Medium Voltage Cable with Aluminium Wire and AWA Armoured Flame-retardant Power Cable is designed for industrial power distribution, providing mechanical protection and fire safety in critical environments. The aluminium conductor ensures lightweight and cost-effective power transmission, while the AWA (Armour Wire Armour) layer offers robust mechanical protection
Cable de baixa tensão NYY-J NYY-O
Flame retardant LV Low Voltage Cable 0.6/1kV CU/ XLPE/STA/PVC Class C power cable APPLICATION This product is suitable for use in circuits with a rated voltage not exceeding 0.6/1kV, for the purpose of power transmission and distribution. CONSTRUCTION Conductor: Class 1 or class 2 stranded Copper conductor Insulation: Cross-Linked Polyethylene(XLPE) Inner sheath: Polyvinyl chloride (PVC) Armour: Single core: Steel Tape Multi core: Galvanized Steel Tape Outer sheath: Polyvinyl
MV Steel Wire Armoured Cable CU/XLPE/CTS/STA/PVC Flame-retardant Power Cable
MV Steel Wire Armoured Cable CU/XLPE/CTS/STA/PVC Flame-retardant Power Cable APPLICATION Industrial & Utility Power Distribution Underground & Trench Laying Flame-Retardant Environments High-Temperature & Corrosive Conditions Medium-Voltage Networks (Up to 35kV) CONSUCTRUCTION Conductor: Compacted conductors Conductor Shield: Semi conductive shielding material (below 500mm 2 ) Semi conductive tape+semi conductive shielding material (500 mm 2 and above) Insulation:
XHHW-2 600V cabo de alimentação de alumínio condutor série AA8000 XLPE isolamento
XHHW-2 600V Aluminium Conductor Cable AA8000 Series XLPE Insulation Application The AA-8000 series aluminum alloy cables (e.g., AA-8030, AA-8176) are widely used in electrical systems due to their lightweight, cost-efficiency, and superior mechanical/electrical performance compared to pure aluminum. 1. Power Distribution Building Wiring: Branch circuits, feeders, and service entrance cables (NEC Article 310 compliant). Utility Grids: Overhead lines and underground distributio
Cable de alimentação de alumínio de núcleo único blindado STA 35kV Cu XLPE PVC STA
400sq mm Single Core Aluminium Conductor Cable Armoured STA 35kV Cu/XLPE/PVC/STA Application Renewable Energy Systems : Widely used in solar farms and wind power projects due to lightweight design and corrosion resistance Industrial and Urban Infrastructure : Ideal for underground burial, tunnels, and industrial plants requiring durable, corrosion-resistant power distribution Transportation Networks : Deployed in subways, railways, and airports where flexibility and
AAC cabo de alumínio condutor XLPE/PVC/STA cabo de alimentação de tensão média 8,7 15kV
AAC Aluminium Conductor Cable XLPE/PVC/STA Medium Voltage Power Cable 8.7 15kV APPLICATION Suitable for urban underground power grids, power station outgoing lines, internal power supply lines of industrial and mining enterprises, etc. CONSTRUCTION Conductor: Round compacted conductors Conductor Shield: Semi conductive shielding material (below 500mm ) Semi conductive tape+semi conductive shielding material (500 mm and above) Insulation: Polyvinyl chloride (PVC) Insulation
Cable de alimentação HV de 110 kV com classificação de incêndio com as normas IEC 60840 e IEC 62067 para redes de distribuição
Fire Rated 110kV HV Power Cable with IEC 60840 and IEC 62067 Standards for Distribution Networks APPLICATION The cable is mainly used in underground, indoor, and tunnel installations requi ring fire resistance, and typically suitable in power plants, substations, and critical urban infrastructure. CONSTRUCTION Conductor: Stranded circular or segmental (Milliken) compacted copper conductor Conductor shield: Semi-conductive shield Insulation: Cross-Linked Polyethylene(XLPE)