xlpe insulated cable
"
Cabos de instrumentação blindados CU LSZH LSZH SWA blindados
Copper Screened Shielded instrumentation cable CU/LSZH/LSZH SWA Armoured Application Shielded Instrument Cable is used as signal transmission and connection of checking appliances of distribution system, computer system and automatic system of power. For use in installations designed to connect electrical instrumentation circuits and provide communication services in and around process plants. Suitable for direct burial applications Construction Conductor: Copper, tinned
15kV 35kV ACSR Condutor ABC Cable Aerial Bundled Cable de Voltagem Média Cable aéreo
15kV 35kV ACSR Conductor ABC Aerial Bundled Cable Medium Voltage Overhead Cable APPLICATION 1 phase:t o supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 1000 volts or lower at a conductor temperature of 75℃ maximum. 2 phase: t o supply power from the utility ’ s lines to the consumer ’ s weatherhead. For service at 1000 volts or less (phase to phase) at a conductor temperature of 75℃ maximum for polyethylen
Cabo Solar PV Isolado PVC 1 Núcleo Cabo Solar PV Resistente ao Calor para Painel Solar
PVC Insulated PV Solar Cable 1 Core Heat Resistant PV Solar Panle Cable APPLICATION Photovoltaic (PV) Power Plants : Used for interconnecting solar panels, inverters, and combiner boxes in utility-scale solar farms. Designed to withstand extreme outdoor conditions, including prolonged UV exposure and temperature fluctuations (-40°C to +120°C) Rooftop Solar Systems: Critical for residential/commercial installations where cables are routed through high-heat zones (e.g., under
Cabo Aéreo Feixe (AAF) AAC AAAC ACSR 15/35kV para Linhas de Energia
AAC AAAC ACSR Self Supporting Aerial Bundled Cable ABC Cable for Overhead Power Line APPLICATION AAC (All Aluminum Conductor) and AAAC (All Aluminum Alloy Conductor) are widely used in medium-voltage distribution networks (e.g., rural electrification, urban overhead lines) due to their lightweight and corrosion resistance. ACSR (Aluminum Conductor Steel Reinforced) is ideal for high-voltage transmission lines (e.g., 11kV-33kV) and long-distance power delivery, thanks to its
Cabo Blindado de Liga de Alumínio com Fita de Cobre e Armadura SWA de 18kV para Distribuição de Energia Subterrânea
18kV SWA Armoured Aluminium Alloy Conductor Copper Tape Screened Cable for Underground Power Distribution Application The 18kV SWA Armoured Aluminium Alloy Conductor Copper Tape Screened Cable is primarily used for medium voltage underground power distribution systems. It is designed to deliver reliable electrical power in demanding environments where mechanical protection and electrical shielding are required. This cable is widely applied in: Urban power distribution
Cable Aéreo em conjunto ABC Cable de energia de alumínio condutor
Weather Resistant Aerial Bundled Cable ABC Aluminum Conductor Power Cable And Wire Applicatiom Aerial Bundled Cable(overhead cables)is applied for elelctric power distribution in low voltage metropolitan,suburban and rural networks,for public lighting and house connections.Laid on pillars and house fronts Characteristics 1.Temperature Rating:-20ºC up to +90ºC 2.Voltage Rating:600/1000V 3.Min inner bending radius: Up to 25mm:4x overall diameter Above 25mm:6x over diameter 4
1Kv PE PVC Isolamento Aéreo ABC Cable Alumínio Conductor Overhead Cable
600V ABC Aerial Bundled Cable Prefabricated 4X35 XLPE Insulation Standard Cable Application: This product is suitable for overhead power lines that are easy to produce short circuit faults and safety hazards to humans and animals through dense forests and trees Construction Conductor : Aluminum (lightweight, cost-effective). Insulation :PE or PVC. Sheath : Typically low-smoke halogen-free (LSHF) compound for reduced toxicity and smoke emission during fires. Specifications LV
Cabo de transmissão aérea ABC de tensão média 11 kV
Medium Voltage 11kV Aerial Bundled ABC Cable Overhead Transmission Cable Application This product is suitable for overhead power lines that are easy to produce short circuit faults and safety hazards to humans and animals through dense forests and trees Construction Conductor : Aluminum (lightweight, cost-effective). Insulation :PE or PVC. Sheath : Typically low-smoke halogen-free (LSHF) compound for reduced toxicity and smoke emission during fires. Specifications No of cores
Cabo de tensão média retardador de chama 12/20kV N2XSH Single Core Three Core
Flame-retardant Medium Voltage Cable 12/20kV N2XSH Single Core Three Core APPLICATION Suitable for power supply lines with flame retardant requirements, such as urban underground power grids, power station outgoing lines, and internal power lines of industrial and mining enterprises. CONSTRUCTION C onductor: Tightly press circular conductor Conductor shield: S emi conductive shielding material (below 500mm ² ) Semi conductive tape+semi conductive shielding material (500mm ²