pvc insulated cable
"
STA Retardante de Chama Cabos Elétricos Blindados PVC Banda de Aço revestida Cabos Blindados
Flame Retardant STA Armoured Electrical Cable PVC Sheathed Control Cables Application Armored cables designed for permanent installations, suitable for both indoor and outdoor use, whether installed in air or underground.They can be mounted on walls, placed in cable ducts, or laid on cable trays.These cables are not intended for installation in wet or submerged conditions. Construction Conductor: Solid or Stranded Copper Conductor Insualtion: XLPE Inner Sheath: PVC Armor:
600V XLPE Cable de isolamento aéreo em conjunto ABC Overhead Twisted Cable
600V XLPE Insulation ABC Aerial Bundled Cable and Overhead Twisted Cable Applicatiom Low voltage aerial cable is designed to supply 600/1000-volt aerial service for temporary service at construction sites, as a service drop (power pole to service entrance), as a secondary cable (pole to pole) or street lighting. This over-head cable provides reinforced insulation acc. Characteristics Voltage rating: 1kV Test voltage: 4kV, 5min no breakdown. Operating temperature PVC: -15°C to
MV Medium Voltage Copper SWA Armored Cable 8.7KV 15kV Armored Electrical Wire
MV Medium Voltage Armoured Electrical Cable SWA 8.7/15kV Cu/XLPE/PVC/SWA Construction Conductor: Circular compacted stranded Copper or aluminium Conductor screen: Extruded semi-conductive compound Insulation: XLPE Insulation screen: Extruded semi-conductive compound Metallic screen: Copper Wire Binder tape: non-hygroscopic material Inner covering(bedding): PVC Metallic armor: Galvanized steel tape Application Common applications include mining operations, oil and gas
Cable de baixa tensão NYY-J NYY-O
Flame retardant LV Low Voltage Cable 0.6/1kV CU/ XLPE/STA/PVC Class C power cable APPLICATION This product is suitable for use in circuits with a rated voltage not exceeding 0.6/1kV, for the purpose of power transmission and distribution. CONSTRUCTION Conductor: Class 1 or class 2 stranded Copper conductor Insulation: Cross-Linked Polyethylene(XLPE) Inner sheath: Polyvinyl chloride (PVC) Armour: Single core: Steel Tape Multi core: Galvanized Steel Tape Outer sheath: Polyvinyl
19/33kV XLPE isolado de média tensão MV ABC cabo com tela de cobre
19/33kV Screened Medium Voltage MV ABC Cable IEC 60502 Compliant 3X150mm + 1X50mm Configuration Applications Suitable for indoor/outdoor installations, cable trenches, tunnels, and underground or underwater deployments Used in power distribution networks, substations, and industrial plants requiring 19/33kV voltage levels Ideal for magnetic duct-free environments (single-core cables are restricted in magnetic ducts) Construction Conductor: Circular Compacted Stranded H68
Cabo de energia isolado XLPE 0,6/1kV N2XY N2X2Y Certificado EAC Cabo de energia retardante de chama
0.6/1kV XLPE Insulated Power Cable N2XY N2X2Y EAC Certified Flame-retardant Power Cable APPLICATION Fixed installations in power distribution networks, industrial plants, and urban infrastructure Flame-retardant applications requiring compliance with IEC 60331 and EAC safety standards Indoor/outdoor use in cable trunking, underground ducts, or direct burial, withstanding temperatures from -60°C to +200°C EMC protection in industrial environments due to its
Cabo de baixa tensão não blindado 0,6/1kV Conductor de cobre XLPE Isolamento PE revestido Cabo de alimentação resistente ao fogo
Non Armoured Low Voltage Cable 0.6/1kV Copper Conductor XLPE Insulation PE Sheathed Fire-resistant Power Cable Application Application of Non Armoured Low Voltage Cable 0.6/1kV Copper Conductor XLPE Insulation PE Sheathed Fire-resistant Power Cable This cable is widely used in industrial and commercial buildings where fire safety is critical. It is commonly installed in power distribution systems, emergency lighting circuits, and fire alarm systems. Due to its flame
500mm2 630mm2 800mm2 Cabo Armado SWA 35kV CU/XLPE/CTS/SWA/PVC para Redes de Energia Subterrâneas Urbanas
500mm2 630mm2 800mm2 SWA Armoured Cable 35kV CU/XLPE/CTS/SWA/PVC for Urban Underground Power Grids APPLICATION Power Transmission and Distribution Industrial Power Supply Direct Burial and Underground Installation Underwater and Harsh Environment Use CONSTRUCTION CHARACTERISTICS Voltage Rating Uo/U: 19 /3 3 (36 ) kV Maximum operating temperature of conductor: +90℃ Operating ambient temperature: -15℃~+55℃ Cable laying temperature: Not less than 0℃(When the ambient
Cable MV 100% isolado 1X630mm2 Condutor de cobre XLPE isolado 25kV
100% Insulated MV Cable 1X630mm2 Copper Conductor XLPE Insulated 25kV Applications The cable is used to transmit large amounts of electrical power at 25 kV from substations to industrial or infrastructure loads. Construction Conductor: Compacted conductors Conductor Shield: Semi conductive tape+semi conductive shielding material Insulation: XLPE Insulation Shield: Peelable semiconducting shielding material Metal Shield Layer: Copper Tape Filler: Polypropylene (PP) m esh f