logo

110kV XLPE Insulated 630mm² Copper Cable with Welded Corrugated Aluminum Sheath

خواص اساسی
محل مبدا: هبی، چین
نام تجاری: OEM
گواهینامه: CCC,ISO,TUV,CE, EAC
شماره مدل: قدرت بالا
املاک تجاری
حداقل مقدار سفارش: قابل مذاکره
قیمت: قابل مذاکره
شرایط پرداخت: L/C، T/T، وسترن یونیون
توانایی تامین: 100 کیلومتر در هفته
مشخصات
Type: ولتاژ بالا 110 کیلو ولت Conductor material: Coppe
Insulation material: 110 کیلوولت XLPE Section area: 630 میلی متر مربع
Sheath: غلاف آلومینیومی راه راه ویلد شده Usage: کابل زیرزمینی، کابل لوله
توضیحات محصول

110kV XLPE Insulated 630mm² Copper Cable with Welded Corrugated Aluminum Sheath


This single-core 110kV copper cable is engineered for high-voltage power transmission where overhead lines are not an option. With a $630text{ mm}^2$ cross-section and a welded corrugated aluminum sheath (W CAS), it provides a 100% waterproof barrier and heavy mechanical protection for underground city grids, substations, and large industrial projects.


Cable Construction 

High-voltage stability depends entirely on structural layers. This 110kV cable is built as follows:

  1. Conductor: $630text{ mm}^2$ Compacted Stranded Plain Copper (Round or Segmented Milliken design to reduce skin effect).

  2. Conductor Screen: Extruded semi-conducting layer to smooth out electrical stress.

  3. Insulation: Super-clean, high-voltage Cross-linked Polyethylene (XLPE).

  4. Insulation Screen: Extruded semi-conducting layer for radial electric field uniformity.

  5. Water-blocking Layer: Semi-conducting waterproof tape to prevent longitudinal water migration.

  6. Metallic Sheath: Welded Corrugated Aluminum Sheath (W CAS). Acts as a 100% radial water barrier and heavy grounding conductor.

  7. Outer Jacket: High-Density Polyethylene (HDPE) or Flame-Retardant PVC with a conductive graphite coating for outer sheath fault testing.


Where This Cable is Used

  • Substations: Connecting main transformers to the high-voltage grid.

  • City Grid Undergrounding: Replacing bare overhead wires in urban areas via cable tunnels or buried ducts.

  • Heavy Industry: Powering mega-scale facilities like steel mills, chemical plants, and data centers.


How It Solves Site Installation Problems

  • 100% Moisture Protection: The welded corrugated aluminum sheath leaves no seams. It completely blocks underground water, stopping water-trees from growing in the XLPE insulation.

  • High Earth-Fault Capacity: The thick aluminum sheath acts as a reliable grounding conductor, safely carrying high short-circuit currents during grid faults.

  • Easier Bending in Tunnels: The corrugated design makes the cable more flexible than smooth aluminum or lead sheaths, meaning faster pulling through tight curves and narrow trenches.

  • No Need for Concrete Conduits: The rigid aluminum structure easily withstands rock impact and soil pressure, allowing for direct burial and lower civil engineering costs.


Technical Data

  • Voltage Rating: 64/110kV (Max. system voltage: 126kV)

  • Conductor Size: $630text{ mm}^2$

  • Standards: IEC 60840, GB/T 11017

  • Operating Temperature: 90°C continuous, 250°C short-circuit peak

  • Laying Formation: Trefoil or Flat layout


Testing & Factory Acceptance (FAT)

We do not ship unverified cables. Every length is tested in our high-voltage laboratory before loading:

  • 100% Partial Discharge (PD) Testing and AC withstand testing inside our Faraday cage.

  • We welcome third-party inspectors from SGS, Bureau Veritas (BV), or Intertek for onsite or remote video FAT.

  • All orders are shipped on heavy-duty, reinforced steel drums with sealed ends to keep moisture out.


FAQ

Q: Why use a corrugated aluminum sheath instead of a lead sheath?

A: Aluminum is much lighter than lead, making the cable easier to pull. It also gives you much higher mechanical strength for direct burial and better current capacity during earth faults.

Q: What is the current rating (ampacity) for this 630mm² cable?

A: It depends on your layout (trefoil or flat), burial depth, and soil temperature. Send us your trench details and we will run the exact calculation for you.

Q: Do you supply the matching 110kV joints and terminations?

A: Yes. We supply complete systems, including compatible GIS terminations, outdoor porcelain/composite terminations, and straight-through joints.

Q: What is the warranty?

A: 24 months from site commissioning or 36 months from the Bill of Lading (B/L) date. The actual design life is over 40 years.


3 Core Medium Voltage Cable CU/XLPE/CTS/SWA/PVC to IEC 60502-2  1

NCYRY-cc Control Cable 0.6/1kV PVC Insulated PVC Sheathed for Nigeria Market 3

NCYRY-cc Control Cable 0.6/1kV PVC Insulated PVC Sheathed for Nigeria Market 4