logo
발견 296 제품 "

xlpe insulated wire

"
품질 3코어 중전압 케이블 XLPE/ PVC/ STA 지하 전송 케이블 공장

3코어 중전압 케이블 XLPE/ PVC/ STA 지하 전송 케이블

Three Core Medium Voltage Cable XLPE/ PVC/ STA Underground Transmission cable Construction Conductor: Round compacted conductors Conductor Shield: Semi conductive shielding material (below 500mm) Semi conductive tape+semi conductive shielding material (500 mm and above) Insulation: Polyvinyl chloride (PVC) Insulation Shield: Peelable semiconducting shielding material Metal Shield Layer: Copper Tape Copper Wire(35kV 500mm above) Filler: Polypropylene (PP) m esh f illing r ope

품질 구리 와이어 스크린 저전압 케이블 단일 코어 0.6/1kV PVC 단열 케이블 공장

구리 와이어 스크린 저전압 케이블 단일 코어 0.6/1kV PVC 단열 케이블

Copper Wire Screen Low Voltage Cable Single Core 0.6/1kV PVC Insulated Cable APPLICATION Copper-shielded low-voltage cables are widely used in environments requiring reliable power transmission with electromagnetic interference (EMI) protection CONSTRUCTION Conductor:Circular, solid, compacted or sector shaped stranded Copper or aluminum Insulation:XLPE Filler: Non-hygroscopic material Screen: Copper Wire Binder tape:: Non-hygroscopic material Sheath PVC Characteristics Test

품질 CU XLPE PVC 저전압 전력 케이블 구리 와이어 보호 케이블 0.6/1kV 공장

CU XLPE PVC 저전압 전력 케이블 구리 와이어 보호 케이블 0.6/1kV

CU/XLPE/PVC Low Voltage Cable Copper Wire Shielded Cable 0.6/1kV Application The cable could be laying indoors, in tunnel, cable trench, or direct in ground, they can bear external mechanical forces, but unable to bear large pulling force. Construction Conductor:Circular, solid, compacted or sector shaped stranded Copper or aluminum Insulation:XLPE Filler: Non-hygroscopic material Screen: Copper Wire Binder tape:: Non-hygroscopic material Sheath PVC Characteristics Test

품질 LSZH 산업 및 공공 인프라를 위한 구리 선도자와 XLPE 단열을 가진 저전압 케이블 공장

LSZH 산업 및 공공 인프라를 위한 구리 선도자와 XLPE 단열을 가진 저전압 케이블

LSZH Low Voltage STA Low Smoke Zero Halogen Cable N2X2Y Applications Industrial Machinery Public Infrastructure Renewable Energy Systems Underground or Duct Installation Temporary Power Supply Fire-Sensitive Areas Construction Conductor: Class 1/Class 2 stranded Copper conductor Refractory layer: Single sided gold mica tape Insulation: XLPE Filler (options): Polypropylene mesh tear rope or flame-retardant filling Outer sheath: LOSH Characteristics Voltage Rating: Uo/U: 0.6

품질 중압 철 테이프 장갑 케이블 AA-8000 시리즈 구리 와이어 보호 공장

중압 철 테이프 장갑 케이블 AA-8000 시리즈 구리 와이어 보호

Steel Tape Armoured Electrical Cable AA-8000 Series Copper Wire Shield XLPE/PVC/STA Medium Voltage Application Steel tape armored medium-voltage cables are designed for harsh environments requiring robust mechanical protection. Construction Conductor Conductor Shiel Insulation Metal Shield Layer Filler Binder Tape Armouring Outer sheath Laying Method Pipe laying, trench laying, tunnel laying, vertical shaft and bridge laying, etc. Specification KYJLH(S)V62 YJLH(S)V18/30kV C

품질 3 코어 150mm 장갑 케이블 PVC/SWA Cu 8.7/15Kv 카탈로그 지하 전기 전선 종류 공장

3 코어 150mm 장갑 케이블 PVC/SWA Cu 8.7/15Kv 카탈로그 지하 전기 전선 종류

3 Core 150 mm Armoured Cables PVC/SWA Cu 8.7/15Kv Catalogue Underground Electrical Wire Types APPLICATION It is suitable for transmitting electric energy in high and low voltage power lines, and is laid indoors, in cable trenches, pipelines, directly buried, etc. in metallurgy, electric power, construction and other industries and can withstand the action of external mechanical forces. ‌ CONSTRUCTION CHARACTERISTICS The maximum rated temperature of the cable conductor is 90℃.

품질 알루미늄 에어리온 팩들드 케이블 ABC 4 코어 저전압 오버헤드 전기 전선 공장

알루미늄 에어리온 팩들드 케이블 ABC 4 코어 저전압 오버헤드 전기 전선

ABC Aluminum Aerial Bundled Cable 4 Cores Low Voltage Overhead Applications Rural electrification (replacing bare conductors for safety) Urban power lines (reducing installation space and improving reliability) Storm-prone areas (better resistance to wind and weather than traditional open wiring) Advantages Insulated conductors prevent short circuits & improve safety Lightweight aluminum cores reduce sagging and support longer spans UV-resistant sheath for durability in

품질 0.6/1kV 내화 전력 케이블 CU/ XLPE/ PVC 07V-Z IEC 60332-3C IEC 60331 공장

0.6/1kV 내화 전력 케이블 CU/ XLPE/ PVC 07V-Z IEC 60332-3C IEC 60331

0.6/1kV Fire Resistant Power Cable CU/ XLPE/ PVC 07V-Z IEC 60332-3C IEC 60331 APPLICATION This product is suitable for use in line filling circuits rated voltage not exceeding 0.6/1kV for power transmission and distribution ‌ CONSTRUCTION Conductor: Class 1/ Class 2 stranded Copper conductor Refractory layer: Single sided gold mica tape Insulation: XLPE Filler ( options ): Polypropylene mesh tear rope or flame-retardant filling Outer sheath: Polyvinyl chloride (PVC) CHARA C

품질 1.5kV 태양광 PV DC 케이블 기후 저항 H1Z2Z2-K 태양 전지 패널 DC 와이어 공장

1.5kV 태양광 PV DC 케이블 기후 저항 H1Z2Z2-K 태양 전지 패널 DC 와이어

1.5kV DC PV Solar Cable Climate Resistance H1Z2Z2-K Application The cable is designed for connecting photovoltaic system components inside and outside of buildings and equipment with high mechanical requirements and extreme weather conditions.It has the characteristics of Climate resistance, UV resistance,aging resistance,and the service life is over 25years. Construction Conductor: Using multiple tin-plated soft copper wire stranded into insulation Insulation: Irradiation