logo
발견 433 제품 "

pvc insulated cable

"
품질 중압 철 테이프 장갑 케이블 AA-8000 시리즈 구리 와이어 보호 공장

중압 철 테이프 장갑 케이블 AA-8000 시리즈 구리 와이어 보호

Steel Tape Armoured Electrical Cable AA-8000 Series Copper Wire Shield XLPE/PVC/STA Medium Voltage Application Steel tape armored medium-voltage cables are designed for harsh environments requiring robust mechanical protection. Construction Conductor Conductor Shiel Insulation Metal Shield Layer Filler Binder Tape Armouring Outer sheath Laying Method Pipe laying, trench laying, tunnel laying, vertical shaft and bridge laying, etc. Specification KYJLH(S)V62 YJLH(S)V18/30kV C

품질 알루미늄 도체 XLPE SWA LSZH IEC 60502-1 0.6/1kV 케이블 NA2XRH 공장

알루미늄 도체 XLPE SWA LSZH IEC 60502-1 0.6/1kV 케이블 NA2XRH

Aluminium Conductor XLPE SWA LSZH IEC 60502-1 0.6/1kV Cable NA2XRH APPLICATION For installation on or under the plaster Fixed installation indoor, in air or concrete. For buildings or industrial plants with a high density of people or valuable assets. No direct burial or installation in water. Outdoor laying only when protected from direct sunlight and other external impacts CONSUCTRUCTION Conductor: Class 2 stranded aluminium conductorInsulation: XLPE (Cross-Linked

품질 110kV 단일 코어 고전압 케이블 1000mm2 600mm2 지하 전송 케이블 공장

110kV 단일 코어 고전압 케이블 1000mm2 600mm2 지하 전송 케이블

110kV Single Core High Voltage Cable 1000 mm2 600 mm2 3130 mm Underground Transmission Cable Application ‌Power Transmission Systems‌: Primarily used in large-scale power grids to transmit electricity between power stations, substations, and urban distribution networks, especially for voltages above 110kV‌. ‌Electric Vehicles (EVs)‌: Transmit high-voltage electricity (up to 1500V) from batteries to motors, inverters, and charging systems, while also relaying signals to

품질 AA-8000 알루미늄 선도자 XLPE 케이블 서비스 입구 케이블 빌딩 와이어 600V 공장

AA-8000 알루미늄 선도자 XLPE 케이블 서비스 입구 케이블 빌딩 와이어 600V

AA-8000 Aluminum Conductor Service Entrance Cable XLPE Insulation Building Wire Applications XHHW-2 conductors are primarily used in conduit or recognized raceways for services, feeders, and branch circuit wiring as specified in the National Electrical Code. XHHW-2 conductors may be used in wet or dry locations at temperatures not to exceed 90°C. Voltage rating for XHHW-2 conductors is 600 volts. Construction XHHW-2 aluminum conductors are AA-8000 series aluminum alloy,

품질 1.5kV 태양광 PV DC 케이블 기후 저항 H1Z2Z2-K 태양 전지 패널 DC 와이어 공장

1.5kV 태양광 PV DC 케이블 기후 저항 H1Z2Z2-K 태양 전지 패널 DC 와이어

1.5kV DC PV Solar Cable Climate Resistance H1Z2Z2-K Application The cable is designed for connecting photovoltaic system components inside and outside of buildings and equipment with high mechanical requirements and extreme weather conditions.It has the characteristics of Climate resistance, UV resistance,aging resistance,and the service life is over 25years. Construction Conductor: Using multiple tin-plated soft copper wire stranded into insulation Insulation: Irradiation

품질 PV1-F 0.6KV 1.0KV 태양광 전력 케이블 XLPO 지속 가능한 에너지용 태양광 패널 공장

PV1-F 0.6KV 1.0KV 태양광 전력 케이블 XLPO 지속 가능한 에너지용 태양광 패널

PV1-F 0.6/1.0KV Solar Cable XLPO Sheath for Sustainable Energy Solar Panel Applications PV1-F solar photovoltaic (PV) cables are specifically designed for connecting solar panels and components in photovoltaic power generation systems Structure Conductor: Tinned copper (single-core, Class 5 flexible stranded wire). Insulation: PVC (Polyvinyl Chloride) – Provides electrical insulation and mechanical protection. Jacket: XLPO Features UV & Weather Resistant – Designed for

품질 쌍핵 태양 전지 패널 연결 케이블 H1z2z2-K PV1-F PV 와이어 열 저항 공장

쌍핵 태양 전지 패널 연결 케이블 H1z2z2-K PV1-F PV 와이어 열 저항

Twin Core Solar Cable H1z2z2-K PV1-F PV Wire Application Solar cables applies to low smoke halogen-free, flexible, single-core power cables with cross linked insulation and sheath. In particular for use at the direct current (d.c.) side of photovoltaic systems, with a nominal d.c. voltage of 1.5 kV between conductors and between conductor and earth. The cables are suitable to be used with Class II equipment. The cables are designed to operate at a normal maximum conductor

품질 N2XBY NA2XBY 3 코어 저전압 케이블 0.6/1kV 0.5~800MM2 lV 케이블 공장

N2XBY NA2XBY 3 코어 저전압 케이블 0.6/1kV 0.5~800MM2 lV 케이블

N2XBY NA2XBY Low Voltage Cable 3 Core 0.6/1kV 0.5 ~ 800MM2 Construction Conductor: Circular, solid, compacted or sector shaped stranded Copper or aluminum Insulation: XLPE Filler: non-hygroscopic material Binder tape: non-hygroscopic material Sheath: PVC Characteristics Test Voltage: 3.5kV 5min No Breakdown The ambient temperature for installation: ≥0℃. Maximum conductor temperature in normal operation:≤90℃. Max operating temperature of con. When cable short-circuited(5s

품질 철선 장갑 방화 케이블 0.6 1.0kV 두 개의 코어 열 방지 전기 케이블 공장

철선 장갑 방화 케이블 0.6 1.0kV 두 개의 코어 열 방지 전기 케이블

Steel Wire Armoured Fire Resistant Cable 0.6/1.0kV Two Core Application Fire resistant cables can be used in several critical buildings where safety against fire is mandatory to reduce the risk of death as: Hospitals & Old people’shomes. Schools & Recreational buildings. Museums & Historical places. Undergrounds & Tunnels. Railways & Airports. Shopping Centers & Malls. Theatres & Cinemas. Hotels & Offices. High-rise buildings Construction Conductor: Plain Annealed