pvc insulated cable
"
0.6KV 1kv 저전압 에어리언 팩들드 케이블 1 2 3 4 코어 ABC 와이어 XLPE 단열
0.6/1kv Low Voltage Aerial Bundled Cable 1 2 3 4 Cores ABC Wire Applicatiom The aerial bundled cables designed for overhead distribution lines have all conductors made of aluminium, insulated with XLPE.Phase and neutral cores are laid up in a bundle with a left hand lay. Can be used for fixed installation as overhead power lines up to 1000V. Characteristics Voltage rating: 1kV Test voltage: 4kV, 5min no breakdown. Operating temperature PVC: -15°C to +70°C PE: -40°C to +70°C
LSZH 산업 및 공공 인프라를 위한 구리 선도자와 XLPE 단열을 가진 저전압 케이블
LSZH Low Voltage STA Low Smoke Zero Halogen Cable N2X2Y Applications Industrial Machinery Public Infrastructure Renewable Energy Systems Underground or Duct Installation Temporary Power Supply Fire-Sensitive Areas Construction Conductor: Class 1/Class 2 stranded Copper conductor Refractory layer: Single sided gold mica tape Insulation: XLPE Filler (options): Polypropylene mesh tear rope or flame-retardant filling Outer sheath: LOSH Characteristics Voltage Rating: Uo/U: 0.6
0.6/1KV NCYY NAYY 저전압 케이블 PVC/CU 3+2 코어 4+1 코어
0.6/1KV NCYY NAYY Low Voltage Cable PVC/PVC/CU 3+2 Core 4+1Core Application Low voltage cables (typically rated for 0.6/1kV or below) are widely used in power distribution and electrical systems across multiple industries. Key applications include: Building & Construction, Industrial Facilities, Infrastructure & Utilities, Special Environments Construction Conductor:Copper Insulation:PVC Filler: Non-hygroscopic material Binder tape:Non-hygroscopic material Sheath : PVC
멀티 페어 꼬임 차폐 계측 케이블 2/4/5/12 페어 20awg 22awg 24awg
Multi Pair Twisted Shielded Instrument Cable 2/4/5/12 Pair 20awg 22awg 24awg APPLICATION Multi pair twisted cables are fundamental in modern communication and data transmission systems, offering reliable performance across various industries. Their structured design with individually twisted wire pairs minimizes electromagnetic interference (EMI) and crosstalk, making them indispensable in: Telecommunications Networking Infrastructure Industrial Automation Audio-Visual
15/35kV AAC AAAC ACSR 상부 전력 라인을 위한 에어리얼 펀들드 케이블
AAC AAAC ACSR Self Supporting Aerial Bundled Cable ABC Cable for Overhead Power Line APPLICATION AAC (All Aluminum Conductor) and AAAC (All Aluminum Alloy Conductor) are widely used in medium-voltage distribution networks (e.g., rural electrification, urban overhead lines) due to their lightweight and corrosion resistance. ACSR (Aluminum Conductor Steel Reinforced) is ideal for high-voltage transmission lines (e.g., 11kV-33kV) and long-distance power delivery, thanks to its
Overhead Insulated ABC Cable NFC 33-209 0.6/1kV for Power Distribution
Overhead Insulated ABC Cable NFC 33-209 0.6/1kV for Power Distribution APPLICATION Overhead Power Distribution Rural Electrification & Remote Areas Industrial & Commercial Installations Service Connections Renewable Energy Projects CONSTRUCTION Phase conductors: AAC Insulation: XLPE, UV-resistant. Neutral-supported: AAAC Street lighting conductor: AAC Core identification: Ribs or numbers or colors stripe. SPECIFICATION Number of Cores x Nominal Cross Section Approx.
6.35/11kV & 12.7/22kV 비 스크린 ABC (AS NZS 3599.1 AL/XLPE/HDPE) 에 대한 항공용 융합 케이블
6.35/11kV & 12.7/22kV Non Screened ABC –Aerial Bundled Cables to AS NZS 3599.1 AL/XLPE/HDPE Applicatiom Primary/Secondary Distribution: Ideal for urban/rural electrification with enhanced safety (reduced outage risks). Bare Transmission: Utilized as overhead conductors in high-voltage grids. Hybrid Systems: Compatible with ACSR (Aluminum Conductor Steel Reinforced) for strength-optimized designs. Characteristics Rated Voltage: 0.6/1 Kv,6.35/11kV,12.7/22kV Up to 33KV
EAC 인증 0.6/1kV 저전압 전력 케이블 VVg VVgng 불 retardant 케이블
EAC Certificated 0.6/1kV Low voltage Power Cable VVg VVgng Flame-retardant Cable APPLICATION The cable is designed for fixed electrical installations in industrial and nuclear power plants, ensuring safe energy transmission under AC voltage (0.66/1/3 kV, 50 Hz) or DC voltage (1/1.5/4.5 kV). CONSTRUCTION Conductor: Class 1/ Class 2 stranded Copper conductor Insulation: Polyvinyl chloride (PVC) Filler ( options ): Polypropylene mesh tearing rope Outer sheath: Polyvinyl
태양광 발전 케이블 2mm, 4mm, 6mm, 10mm H1z2z2-k DC PV 케이블
Solar Photovoltaic Cable 2mm, 4mm, 6mm, 10mm H1z2z2-k DC PV Cable APPLICATION Tailored for DC solar PV systems , these cables feature flame-retardant, UV-resistant, and weatherproof properties, with varied applications based on current capacity: 2mm² : Connects small PV module strings, portable solar panels (RV/garden lights) & compact off-grid systems, ideal for tight routing spaces. 4mm² : The go-to choice for residential/light commercial setups, linking module strings to