aluminum conductor wire
"
트리플렉스 UD 케이블 ABC 연선 케이블 19/33kV 스크린 MV 케이블 IEC 60502
Triplex UD Cable ABC Aerial Bundled Cables 19/33kV Screened MV Cable to IEC 60502 APPLICATION Triplex UD Cable ABC Aerial Bundled Cables 19/33kV Screened cable is primarily used in overhead power distribution networks for transmitting electrical energy. It is designed for aerial installation and is suitable for medium-voltage applications (19kV to 33kV). The cable features a screened design to enhance electromagnetic compatibility and reduce interference. It is
18/30kV 19/33kV SWA 중압 케이블 단일 코어 PVC 재킷 YJV32 YJLV42
18/30kV 19/33kV SWA Medium Voltage Cable Single Core PVC Jacket YJV32 YJLV42 Application Mine environments: In mines, cables need to withstand large mechanical stresses and harsh environmental conditions. The thick steel wire armor and good insulation performance of YJV42 cable enable it to operate safely and reliably in mines, providing power support for mining equipment. Industrial installations: Suitable for various industrial settings where reliable power transmission is
ABC 에어리얼 펀들드 케이블 2 코어 저전압 XLPE 단열 검은색
ABC Aerial Bundled Cable 2 Cores Low Voltage XLPE Insulation Applications Aerial Bundled Cable (ABC) is widely used in overhead low-voltage power distribution (typically up to 1kV). Its key applications include: Rural & urban power lines – Replaces bare conductors for improved safety and reliability. Storm-prone areas – Resists wind, rain, and environmental damage better than traditional wiring. Crowded or narrow spaces – Compact bundled design minimizes installation space.
난연 중전압 케이블 12/20kV N2XSH 단심/삼심
Flame-retardant Medium Voltage Cable 12/20kV N2XSH Single Core Three Core APPLICATION Suitable for power supply lines with flame retardant requirements, such as urban underground power grids, power station outgoing lines, and internal power lines of industrial and mining enterprises. CONSTRUCTION C onductor: Tightly press circular conductor Conductor shield: S emi conductive shielding material (below 500mm ² ) Semi conductive tape+semi conductive shielding material (500mm ²
35KV 1 코어 중전압 케이블 XLPE 단열 1x185 1x300 MV 장갑 케이블
35KV Single Core Medium Voltage Cable XLPE Insulated 1x185 1x300 Construction 1. Conductor- aluminum or copper multiwire circular compacted . 2. Conductor screen - extruded of conductive peroxide cross-linked PE. 3.Insulation - peroxide cross-linked PE. 4. Insulation screen - extruded of conductive peroxide cross-linked PE. 5.Combined screen: 5.1 A layer of conductive paper tapes or conductive polymer tape with minimum thickness of 0.2 mm. 5.2. A layer of copper wires with a
산업용 삼중심 중간 전압 지하 케이블 XLPE 절연, 26KV 35kV 적용
Industrial Three Core Medium Voltage Underground Cable XLPE Insulated 26KV/35kV 26/35kV Industrial Three Core Medium Voltage Cable XLPE Insulated Underground Designed for reliable power transmission in demanding industrial environments with superior insulation and protection. Application Ideal for installation indoors, in tunnels, cable trenches, wells, or direct burial in ground. Engineered to withstand external mechanical forces and significant pulling tension. Cable
보호 된 단일 코어 케이블 중압 PVC 껍질 N2XSRY N2XSERY
Screened Single Core Medium Voltage Power Cables PVC Sheathed N2XSRY N2XSERY Application For laying indoors, in tunnel, cable trench, well or direct in ground, able to bear external mechanical forces and certain pulling force Construction Conductor: Class 2 Aluminium/Copper circular, stranded Conductor Screen: Semi-conductive XLPE (Cross-Linked Polyethylene) Insulation : XLPE (Cross-Linked Polyethylene) Insulation Screen : Semi-conductive XLPE (Cross-Linked Polyethylene)
3코어 중전압 케이블 XLPE/ PVC/ STA 지하 전송 케이블
Three Core Medium Voltage Cable XLPE/ PVC/ STA Underground Transmission cable Construction Conductor: Round compacted conductors Conductor Shield: Semi conductive shielding material (below 500mm) Semi conductive tape+semi conductive shielding material (500 mm and above) Insulation: Polyvinyl chloride (PVC) Insulation Shield: Peelable semiconducting shielding material Metal Shield Layer: Copper Tape Copper Wire(35kV 500mm above) Filler: Polypropylene (PP) m esh f illing r ope
중전압 에어리언 팩들드 케이블 ABC MV 6.35/11kV 19/33kV IEC 60502
Medium Voltage ABC Aerial Bundled Cable MV 6.35/11kV, 19/33kV IEC 60502 Applicatiom Medium Voltage aerial bundled cables are mainly used for secondary overhead lines on poles or as feeders to residential premises. Construction Phase Conductor: Class 2 Circular compacted stranded aluminum Conductor Screen: Extruded semi-conductive layer Insulation: XLPE (Cross-linked polyethylene) Insulation Screen: Extruded semi-conductive layer Metallic Screen: Copper wire screen or copper