logo
발견 57 제품 "

aluminium bare conductor

"
품질 XHWW-2 알루미늄 선도자 MC 케이블 3 코어 4 코어 600V 알루미늄 와이어 공장

XHWW-2 알루미늄 선도자 MC 케이블 3 코어 4 코어 600V 알루미늄 와이어

XHWW-2 Aluminium Conductor Cable 3 Core 4 Core MC cable Application TypeXHHW-2MC cable is suitable for use as branch,feeder and service power distribution.It is suitable for use in wet or dry locations at temperature not to exceed 90°C.If it should be directly buried in the earth,MC cable with PVC sheathis an optimal choice.Maximum voltage rating for XHHW-2 application is 600Volts . Construction Type XHHW-2 conductors which is constructed with 8000 Series Aluminium Alloy

품질 고전압 맨 알루미늄 선도자 AAAC AAC ACSR 전력 전송 라인을 위해 공장

고전압 맨 알루미늄 선도자 AAAC AAC ACSR 전력 전송 라인을 위해

Stranded Bare Conductors Aluminum Cable AAAC, AAC, ACSR High Voltage Application This stranded aac cable is used in high voltage overhead power transmission lines. Compared with ACSR of the same diameter, it has a smaller breaking load and is used in lines where short span and low resistance are required. Description Code name Item Application AAC All-aluminium Conductor Mainly for overhead power transmission and primary and secondary distribution AAAC All Aluminimum Alloy

품질 OEM 600V 알루미늄 선도 케이블 XLPE 단열 8000 Al 합금 시리즈 공장

OEM 600V 알루미늄 선도 케이블 XLPE 단열 8000 Al 합금 시리즈

600V Aluminium Conductor Cable XLPE Insulation 8000 Al Alloy Series Application Long distance wiring on the DC side: suitable for string connection to the DC side of the inverter, especially in large-scale power plants, which can significantly reduce material costs Fixed bracket system: suitable for ground photovoltaic arrays, requiring armor layer (such as steel strip) to resist mechanical damage High humidity/corrosive environment: Aluminum alloy has better chemical

품질 600V SER 서비스 입구 케이블 8000 시리즈 알루미늄 합금 선도자 공장

600V SER 서비스 입구 케이블 8000 시리즈 알루미늄 합금 선도자

SER Service Entrance Aluminium Conductor Cable 8000 series Aluminum Alloy conductor 600V Application Mainly used for distribution cabinets, distribution boards, and other circuit branches in multi residential areas. The maximum operating temperature in damp places is not e xceeding 90 ° C, voltage level 600V. . Construction Conductor: 8000 series aluminum alloy compression conductor Insulation: Silane cross-linked polyethylene (XLPE) XHHW-2 conductor Insulation color

품질 35kV MV 알루미늄 선도자 전력 케이블, XLPE 단열 및 전력 전송을 위한 철강 테이프 장갑 공장

35kV MV 알루미늄 선도자 전력 케이블, XLPE 단열 및 전력 전송을 위한 철강 테이프 장갑

35kV MV Aluminium Alloy Conductor Power Cable AL/XLPE/STA/PVC for Power Transmission Application This 35kV medium-voltage aluminium alloy conductor cable enables efficient, cost-effective power transmission, featuring XLPE insulation for superior dielectric strength, steel tape armoring for robust mechanical protection, and PVC sheathing for moisture and corrosion resistance. Ideal for urban grid upgrades, industrial park power supply, rural long-distance electrification,

품질 사용자 정의 길이 알루미늄 전기 케이블 600V 1000V 알루미늄 선도선 공장

사용자 정의 길이 알루미늄 전기 케이블 600V 1000V 알루미늄 선도선

XLPE Insulated Aluminium Conductor Cable AA- 8000 Series Conductor 600/1000V Application TypeXHHW-2MC cable is suitable for use as branch,feeder and service power distribution.It is suitable for use in wet or dry locations at temperature not to exceed 90°C.If it should be directly buried in the earth,MC cable with PVC sheathis an optimal choice.Maximum voltage rating for XHHW-2 application is 600Volts . Construction Type XHHW-2 conductors which is constructed with 8000 Series

품질 구리 테이프 쉴드 알루미늄 선도 케이블 3.6 KV 6kV 중압 맞춤형 공장

구리 테이프 쉴드 알루미늄 선도 케이블 3.6 KV 6kV 중압 맞춤형

Copper Tape Shield Aluminium Alloy Conductor Cable 3.6/6kV Medium Voltage Application Direct Burial Installation‌: Designed for underground installation with steel tape or steel wire armor, providing superior resistance to mechanical pressure, rodent damage, and insect intrusion in soil environments. Industrial Infrastructure‌: Widely used in cable trenches, trays, and conduits within factories, refineries, and mining facilities, where high mechanical stress and electromagnet

품질 IEC 60502-2 XLPE 단열 알루미늄 장갑 3X300mm 3X150mm 불 retardant 전력 케이블 공장

IEC 60502-2 XLPE 단열 알루미늄 장갑 3X300mm 3X150mm 불 retardant 전력 케이블

IEC 60502-2 XLPE Insulated Aluminium Armoured 3X300mm 3X150mm Flame Retardant Power Cable Applications The cables arewidely used in places such as wind farms and solar power stations to meet the power transmission needs of these places ‌ Main Technical Properties 1. DC resistance of conductor at 20°C : not exceed ing 0.1 Ω/km; 2. 4h Power Frequency Voltage Test (4U₀) : No breakdown occurred; 3. 50Hz AC Withstand Voltage Test: 65 kV for 30 min ; No breakdown occurred; 4.

품질 열 저항성 750 MCM AAAC 알루미늄 합금 선도기 공장

열 저항성 750 MCM AAAC 알루미늄 합금 선도기

Thermal Resistant 750 MCM AAAC Aluminum Alloy Conductor Overhead Power Lines Application Used for overhead power lines, ground wires, steel stay wires Applicable standards: Aluminum alloy conductor (AAAC) are produced according to ASTM B-399, BS EN-50182, AS/NZS 1531, DIN 48201, CSA 61089, IEC 61089, GB/T 1179, BS 3242, NFC 34-125 or the standards agreed by both of the customers and us. Advantages AAAC products have many advantages for use, like low resistance, large carrying

이전
페이지 3 의 7
다음