logo
見つかりました 124 のための製品 "

shielded power wire

"
品質 66KV 69kv 110kv 132KV HVケーブル XLPE insulation 高圧ケーブル 1000MM2 1500MM2 2500M2 工場

66KV 69kv 110kv 132KV HVケーブル XLPE insulation 高圧ケーブル 1000MM2 1500MM2 2500M2

66KV 69kv 110kv 132KV HV Cable XLPE Insulation High Voltage Cable 1000MM2 1500MM2 2500M2 APPLICATION For laying indoors,in tunnel cable trench,well or direct in ground,able to bear external mechanical forces and certain pulling force. CONSTRUCTION Conductor: Stranded circular or segmental (Milliken) compacted copper conductor Conductor shield: Semi-conductive shield Insulation: Cross-Linked Polyethylene(XLPE) Insulation shield: Semi-conductive shield Metal shielding layer:

品質 CY PVC YSLCY Flexible Control Cable with Copper  Braiding and PVC Sheath for instrumentation 工場

CY PVC YSLCY Flexible Control Cable with Copper Braiding and PVC Sheath for instrumentation

CY PVC YSLCY Flexible Control Cable with Copper Braiding and PVC Sheath for instrumentation APPLICATION CY PVC (YSLCY) Flexible Control Cable with Copper Braiding and PVC Sheath is designed for instrumentation and control systems in industrial environments. Its copper braiding provides excellent electromagnetic interference (EMI) shielding, ensuring signal integrity in noisy settings. The PVC insulation and sheath offer durability, flexibility, and resistance to moisture,

品質 送電線用アルミニウム導体鋼心強化ACSS ASTM B 856規格 工場

送電線用アルミニウム導体鋼心強化ACSS ASTM B 856規格

Aluminum Conductor Steel Supported ACSS ASTM B 856 Standard for Transmission Lines What is ACSS Conductor Aluminum Conductor Steel Supported (ACSS) is an upgraded version of traditional ACSR (Aluminum-Clad Steel Reinforced Conductor), representing an aluminum alloy steel-cored supported conductor. It stands as a highly advanced bare conductor in power transmission lines, particularly in high-voltage transmission lines. Consutruction Outer layer: Fully Annealed Aluminum is

品質 銅テープシールド 中圧装甲ケーブル 6KV 10kV 600sq 地下使用 工場

銅テープシールド 中圧装甲ケーブル 6KV 10kV 600sq 地下使用

Copper Tape Shield Medium Voltage 6/10kV Steel Tape Armoured 600sq Underground Use Construction Conductor: Circular compacted stranded Copper or aluminium Conductor screen: Extruded semi-conductive compound Insulation: XLPE Insulation screen: Extruded semi-conductive compound Metallic screen: Copper Wire Binder tape: non-hygroscopic material Inner covering(bedding): PVC Metallic armor: Galvanized steel tape Application Suitable for urban underground power grids, power station

品質 シングルコアAWA装甲ケーブル 12/20kV N2XSRY YJV72 CU/XLPE/CTS AWA/PVC 工場

シングルコアAWA装甲ケーブル 12/20kV N2XSRY YJV72 CU/XLPE/CTS AWA/PVC

Single Core AWA Armoured Cable 12/20kV | N2XSRY – YJV72 | CU/XLPE/CTS/AWA/PVC Medium Voltage XLPE Insulated | Copper Tape Screened | Aluminium Wire Armoured | PVC Sheathed Product Overview The N2XSRY – YJV72 (CU/XLPE/CTS/AWA/PVC) is a single core, medium voltage armoured power cable rated at 12/20(24) kV, designed for primary power distribution networks where superior mechanical protection is essential. This cable combines a high-conductivity copper conductor with cross

品質 100% 絶縁 MV ケーブル 1X630mm2 銅導体 XLPE 絶縁 25kV 工場

100% 絶縁 MV ケーブル 1X630mm2 銅導体 XLPE 絶縁 25kV

100% Insulated MV Cable 1X630mm2 Copper Conductor XLPE Insulated 25kV Applications The cable is used to transmit large amounts of electrical power at 25 kV from substations to industrial or infrastructure loads. Construction Conductor: Compacted conductors Conductor Shield: Semi conductive tape+semi conductive shielding material Insulation: XLPE Insulation Shield: Peelable semiconducting shielding material Metal Shield Layer: Copper Tape Filler: Polypropylene (PP) m esh f

品質 地下サービス入口のための日光耐性のあるアルーミニアム導管ケーブル 工場

地下サービス入口のための日光耐性のあるアルーミニアム導管ケーブル

Stranded Aluminium Conductor Cable Sunlight Resistant For Underground Service Entrance APPLICATION Power Distribution Networks ‌ Building and Construction ‌ Commercial/Residential Wiring High-Rise Buildings ‌ Industrial Facilities Heavy Machinery Power Supply Renewable Energy Systems ‌ Transportation Infrastructure Railways and Airport E V Charging Stations CHARA C TERISTIC Voltage Rating Uo/U: 3.6/6 ( 7.2 ) kV , 6/6 ( 7.2 ) kV , 6/10(12)kV , 8.7/10(12kV ), 8.7/15(17.5)kV ,

品質 耐火 LSZH ケーブル 三芯 MV 8.7/15kV XLPE 絶縁鋼テープ装甲 PVC シース ケーブル 工場

耐火 LSZH ケーブル 三芯 MV 8.7/15kV XLPE 絶縁鋼テープ装甲 PVC シース ケーブル

Fire Protection LSZH Cable Three Core MV 8.7/15kV XLPE Insulated Steel Tape Armored PVC Sheathed Cable Product Overview Fire Rated Low Voltage Wire with 3 Core 1.5-400mm² is engineered to maintain circuit integrity during fire conditions, ensuring continuous power supply for critical emergency systems. Applications Suitable for power supply lines with flame retardant requirements, such as urban underground power grids, power station outgoing lines, and internal power lines of

品質 地下アルミニウム合金電導ケーブル AA-8000シリーズ パーソナライズされた長さ 工場

地下アルミニウム合金電導ケーブル AA-8000シリーズ パーソナライズされた長さ

Underground Aluminum Alloy Conductor Cable AA-8000 Series YJLHV62 YJLHV22 Application The ‌ YJLHV62 YJLHV22 cable ‌ is an aluminum alloy conductor power cable designed for medium-voltage applications, combining durability, flexibility, and environmental resilience. Below is a detailed description: Construction Conductor{ Round compacted conductors Conductor Shield: Semi conductive shielding material (below 500mm) Semi conductive tape+semi conductive shielding material (500 mm

前回
ページ 11 の 14
次へ