logo
見つかりました 124 のための製品 "

shielded power wire

"
品質 EAC Certificated MV Medium Voltage Cable CU/XLPE/STA/PVC Flame-retardant Power Cable 工場

EAC Certificated MV Medium Voltage Cable CU/XLPE/STA/PVC Flame-retardant Power Cable

EAC Certificated MV Medium Voltage Cable CU/XLPE/STA/PVC Flame-retardant Power Cable APPLICATION Suitable for power supply lines with flame retardant requirements, such as urban underground power grids, power station outgoing lines, and internal power lines of industrial and mining enterprises. CONSUCTRUCTION C onductor: Tightly press circular conductor Conductor shield: S emi conductive shielding material (below 500mm ² ) Semi conductive tape+semi conductive shielding

品質 EAC認定のシールド制御ケーブル KVVGeng CU/PVC/CWS/PVC 帯状シールド式耐火性 工場

EAC認定のシールド制御ケーブル KVVGeng CU/PVC/CWS/PVC 帯状シールド式耐火性

EAC Certificated Screened Control Cable KVVGeng CU/PVC/CWS/PVC Braided Shielded Flame-retardant APPLICATION This product is suitable for use in control, monitoring circuits, and protection circuits in circuits with a rated voltage of 450/750V and below CONSTRUCTION Conductor: C ircular solid copper conductor (A) or circular stranded copper conductor (B) Insulation: Polyvinyl chloride (PVC) Filler: Polypropylene netting tear cord or flame-retardant filling Braiding: Soft round

品質 Cu/XLPE/CTS/LSZH/FR/PE 19/33kV 3×300mm² 中圧電力ケーブル 工場

Cu/XLPE/CTS/LSZH/FR/PE 19/33kV 3×300mm² 中圧電力ケーブル

Cu/XLPE/CTS/LSZH/FR/PE 19/33kV 3×300mm² Medium Voltage Power Cable Product Overview The Cu/XLPE/CTS/LSZH/FR/PE 19/33kV 3×300mm² is a high-performance medium voltage power cable designed for critical power distribution networks. This three-core copper cable is manufactured to the highest international standards, featuring cross-linked polyethylene (XLPE) insulation and a copper tape screen (CTS) for superior electrical performance. Rated at 19/33kV, this cable is specifically

品質 難燃性MV中電圧ケーブル 6kV- 26/35kV 鎧装電力ケーブル 工場

難燃性MV中電圧ケーブル 6kV- 26/35kV 鎧装電力ケーブル

Flame-retardant MV Medium Voltage Cable 6kv- 26/35kv Armored Power Cable APPLICATION Suitable for power supply lines with flame retardant requirements, such as urban underground power grids, power station outgoing lines, and internal power lines of industrial and mining enterprises. CONSUCTRUCTION C onductor: Tightly press circular conductor Conductor shield: S emi conductive shielding material (below 500mm ² ) Semi conductive tape+semi conductive shielding material (500mm ²

品質 AAC アルミ電線ケーブル XLPE/PVC/STA 中電圧電力ケーブル 8.7 15kV 工場

AAC アルミ電線ケーブル XLPE/PVC/STA 中電圧電力ケーブル 8.7 15kV

AAC Aluminium Conductor Cable XLPE/PVC/STA Medium Voltage Power Cable 8.7 15kV APPLICATION Suitable for urban underground power grids, power station outgoing lines, internal power supply lines of industrial and mining enterprises, etc. CONSTRUCTION Conductor: Round compacted conductors Conductor Shield: Semi conductive shielding material (below 500mm ) Semi conductive tape+semi conductive shielding material (500 mm and above) Insulation: Polyvinyl chloride (PVC) Insulation

品質 カスタムロゴ 低電圧制御ケーブル 工業用用XLPE保温用PVC帯状 遮蔽式 耐火性 工場

カスタムロゴ 低電圧制御ケーブル 工業用用XLPE保温用PVC帯状 遮蔽式 耐火性

Custom Logo Low Voltage Control Cable XLPE Insulated PVC Braided Shielded Flame-retardant Control Cable for industrial and commercial applications Applications Industrial Automation Ideal for control panels, motor circuits, and instrumentation systems in machinery and production lines. Suitable for environments requiring flame-retardant properties such as chemical plants and oil refineries. Building Management Systems (BMS) Deployed in HVAC, lighting, and security systems for

品質 3.6/6kV26/35kV 中圧ケーブル XLPE 絶縁金属テープ 装甲電源ケーブル 工場

3.6/6kV26/35kV 中圧ケーブル XLPE 絶縁金属テープ 装甲電源ケーブル

3.6/6kV~26/35kV Medium Voltage Cable XLPE Insulation PVC Sheath Metal Tape Armouring Power Cable Application Suitable for urban underground power grids, power station outgoing lines, internal power supply lines of industrial and mining enterprises, etc. CONSTRUCTION Conductor: Round compacted conductors Conductor Shield: Semi conductive shielding material (below 500mm Semi conductive tape+semi conductive shielding material (500 mm 2 and above) Insulation: Polyvinyl chloride

品質 Single Core HV High Voltage Power Cable  2XS(FL)2Y CU/XLPE/CWS/STA/PVC 工場

Single Core HV High Voltage Power Cable 2XS(FL)2Y CU/XLPE/CWS/STA/PVC

Single Core HV High Voltage Power Cable 2XS(FL)2Y CU/XLPE/CWS/STA/PVC APPLICATION Urban underground networks‌ (e.g., substation connections, industrial power distribution)‌ Harsh environments‌ requiring robust mechanical and chemical protection‌ CONSTRUCTION Conductor: Stranded circular or segmental (Milliken) compacted copper conductor Conductor shield: Semi-conductive shield Insulation: Cross-Linked Polyethylene(XLPE) Insulation shield: Semi-conductive shield Metal

品質 銅テープスクリーン付き架空送電用高圧ABCケーブル 工場

銅テープスクリーン付き架空送電用高圧ABCケーブル

Overhead Aerial Cable with Copper Tape Screen MV ABC Cable for Overhead Power Transmission APPLICATION power transmission in overhead distribution networks. Its copper tape screen enhances electromagnetic shielding and current-carrying capacity, while the XLPE insulation ensures durability under various environmental conditions. Ideal for urban and rural areas, this cable supports voltages up to 36kV and is suitable for long-distance aerial installations. The lightweight

前回
ページ 8 の 14
次へ