logo
見つかりました 246 のための製品 "

high voltage power cable

"
品質 高電圧 110kV 装甲電線 1コア 送電 工場

高電圧 110kV 装甲電線 1コア 送電

High Voltage 110kV Armoured Electrical Cable 1 Core CU/XLPE/PVC Application The cables refer to power cables used for transmitting 100kV, mainly for power transmission and distribution. Its voltage level ranges are commonly used for long-distance power transmission and voltage level conversion in substations. Construction Conductor: Class 2 copper conductor compacted or segment strand Milliken Conductor Screen: Extruded semi-conductive XLPE (Cross-Linked Polyethylene)

品質 4芯PE電源ケーブル 銅芯 XLPE絶縁 N2X2Y IEC60852-1規格 工場

4芯PE電源ケーブル 銅芯 XLPE絶縁 N2X2Y IEC60852-1規格

4 Core PE Power Cable Cu Core XLPE Insulated N2X2Y IEC60852-1 Standard APPLICATION PE Power cables are used for low-voltage power distribution (0.6/1 kV) in fixed installations, suitable for indoor and outdoor laying including cable trays, ducts, and conduits, and used in supplying buildings, industrial equipment, and general electrical loads. CONSTRUCTION Type: N2X2Y Conductor: Copper (Cu) Insulation: Cross-Linked Polyethylene (XLPE) Sheath: PE CHARACTERISTIC Rated voltage:

品質 4コア STA 装甲電源ケーブル 0.6/1kV AL導体 NAYBY 工場

4コア STA 装甲電源ケーブル 0.6/1kV AL導体 NAYBY

4 Core STA Armoured Power Cable 0.6/1kV AL Conductor NAYBY APPLICATION The 4 core STA (Steel Tape Armoured) aluminium conductor power cable (NAYBY) is mainly used for low voltage power distribution systems with a rated voltage of 0.6/1kV. It is suitable for transmitting and distributing electrical energy in both industrial and urban networks. CONSTRUCTION Type: NAYBY Conductor: Aluminium (AL) Insulation: PVC Armoured: Steel Tape Armoured(STA) Sheath: PVC CHARACTERISTIC Rated

品質 多核1.5mm低電圧制御ケーブル PVC隔熱銅柔軟ケーブル 工場

多核1.5mm低電圧制御ケーブル PVC隔熱銅柔軟ケーブル

KVV Multi Cores Flexible Control Cable 0.75 1.0 1.5 2.5 Copper Construction 1. Conductor Material: Fine-stranded bare copper (Class 5 per IEC 60228) for high flexibility. Structure: Multiple thin wires tightly bundled to allow repeated bending. 2. Insulation Material: PVC (Polyvinyl Chloride). Function: Provides electrical insulation and mechanical protection. 3. Sheath (Outer Jacket) Material: PVC – Offers abrasion resistance and mild environmental protection. Design: Smooth

品質 ACSRC 自己支持型架空束線 ABC 電力ケーブル IEC228 IEC208 IEC502 架空配電線用 工場

ACSRC 自己支持型架空束線 ABC 電力ケーブル IEC228 IEC208 IEC502 架空配電線用

ACSRC Self-Supporting Aerial Bundled ABC Power Cable IEC228 IEC208 IEC502 For Overhead Distribution Line APPLICATION 1 phase:t o supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 1000 volts or lower at a conductor temperature of 75℃ maximum. 2 phase: t o supply power from the utility ’ s lines to the consumer ’ s weatherhead. For service at 1000 volts or less (phase to phase) at a conductor temperature of 75

品質 MV Steel Wire Armoured Cable CU/XLPE/CTS/STA/PVC Flame-retardant Power Cable 工場

MV Steel Wire Armoured Cable CU/XLPE/CTS/STA/PVC Flame-retardant Power Cable

MV Steel Wire Armoured Cable CU/XLPE/CTS/STA/PVC Flame-retardant Power Cable APPLICATION Industrial & Utility Power Distribution‌ Underground & Trench Laying‌ Flame-Retardant Environments‌ High-Temperature & Corrosive Conditions‌ Medium-Voltage Networks (Up to 35kV)‌ CONSUCTRUCTION Conductor: Compacted conductors Conductor Shield: Semi conductive shielding material (below 500mm 2 ) Semi conductive tape+semi conductive shielding material (500 mm 2 and above) Insulation:

品質 26/35kV AWA armouredケーブル CU/XLPE/AWA/PVC/PE シース難燃性電力ケーブル 工場

26/35kV AWA armouredケーブル CU/XLPE/AWA/PVC/PE シース難燃性電力ケーブル

26/35kV AWA Armoured Cable CU/XLPE/AWA/PVC/PE Sheathed Flame-retardant Power Cable Application The 26/35kV AWA (Aluminium Wire Armoured) copper conductor power cable is designed for medium voltage power transmission and distribution systems up to 35kV. It is widely used in applications requiring high reliability, mechanical protection, and fire safety performance. Main Construction Conductor: Compacted conductors Insulation: PVC Metal Screen: Copper Tape Armouring: Aluminium

品質 XLPE 断熱 4コア 耐熱ケーブル 耐火電源ケーブル OEM 工場

XLPE 断熱 4コア 耐熱ケーブル 耐火電源ケーブル OEM

XLPE Insulation Fire Resistant Cable Flame Retardant sheath Power cable 4 Core Application Fire resistant cables can be used in several critical buildings where safety against fire is mandatory to reduce the risk of death as: Hospitals & Old people’shomes. Schools & Recreational buildings. Museums & Historical places. Undergrounds & Tunnels. Railways & Airports. Shopping Centers & Malls. Theatres & Cinemas. Hotels & Offices. High-rise buildings Construction C ondu

品質 240 -2000MM2 66kV 高電圧ケーブル CU XLPE CAS PE PVC LSHF 地下ケーブル 工場

240 -2000MM2 66kV 高電圧ケーブル CU XLPE CAS PE PVC LSHF 地下ケーブル

240 -2000 MM2 66V High Voltage Cable CU/XLPE /CAS/PE PVC LSHF Underground Cable Application Used for underground power transmission lines; laid on cable ladder, tray, buried direct in the ground or in duct in the ground Construction 1.Conductor 2.Conductor screen 3.XLPE insulation 4.Insulation screen 5.Semiconducting tape 6.Aluminum corrugated sheath 7.PE or PVC outer sheath (Graphite coating or extruded semiconducting) Description Voltage Rating (Uo/U)(Um) : 36/66 kV

前回
ページ 10 の 28
次へ