high voltage power cable
"
Υψηλής τάσης 110kV θωρακισμένο ηλεκτρικό καλώδιο 1 πυρήνας για μετάδοση ισχύος
High Voltage 110kV Armoured Electrical Cable 1 Core CU/XLPE/PVC Application The cables refer to power cables used for transmitting 100kV, mainly for power transmission and distribution. Its voltage level ranges are commonly used for long-distance power transmission and voltage level conversion in substations. Construction Conductor: Class 2 copper conductor compacted or segment strand Milliken Conductor Screen: Extruded semi-conductive XLPE (Cross-Linked Polyethylene)
4-жильный силовой кабель PE с медной жилой, изоляцией из сшитого полиэтилена, N2X2Y, стандарт IEC60852-1
4 Core PE Power Cable Cu Core XLPE Insulated N2X2Y IEC60852-1 Standard APPLICATION PE Power cables are used for low-voltage power distribution (0.6/1 kV) in fixed installations, suitable for indoor and outdoor laying including cable trays, ducts, and conduits, and used in supplying buildings, industrial equipment, and general electrical loads. CONSTRUCTION Type: N2X2Y Conductor: Copper (Cu) Insulation: Cross-Linked Polyethylene (XLPE) Sheath: PE CHARACTERISTIC Rated voltage:
4 πυρήνας STA θωρακισμένο καλώδιο ισχύος 0,6/1kV AL Διοδηγός NAYBY
4 Core STA Armoured Power Cable 0.6/1kV AL Conductor NAYBY APPLICATION The 4 core STA (Steel Tape Armoured) aluminium conductor power cable (NAYBY) is mainly used for low voltage power distribution systems with a rated voltage of 0.6/1kV. It is suitable for transmitting and distributing electrical energy in both industrial and urban networks. CONSTRUCTION Type: NAYBY Conductor: Aluminium (AL) Insulation: PVC Armoured: Steel Tape Armoured(STA) Sheath: PVC CHARACTERISTIC Rated
Πολυπυρηνικό καλώδιο ελέγχου χαμηλής τάσης 1,5 mm PVC μόνωση Χαλκό ευέλικτο καλώδιο
KVV Multi Cores Flexible Control Cable 0.75 1.0 1.5 2.5 Copper Construction 1. Conductor Material: Fine-stranded bare copper (Class 5 per IEC 60228) for high flexibility. Structure: Multiple thin wires tightly bundled to allow repeated bending. 2. Insulation Material: PVC (Polyvinyl Chloride). Function: Provides electrical insulation and mechanical protection. 3. Sheath (Outer Jacket) Material: PVC – Offers abrasion resistance and mild environmental protection. Design: Smooth
ΑΣΚΣΚ Αυτοεφοδιασμένο εναέριο καλώδιο ηλεκτρικής ενέργειας ABC IEC228 IEC208 IEC502 για υπερυψωμένη γραμμή διανομής
ACSRC Self-Supporting Aerial Bundled ABC Power Cable IEC228 IEC208 IEC502 For Overhead Distribution Line APPLICATION 1 phase:t o supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 1000 volts or lower at a conductor temperature of 75℃ maximum. 2 phase: t o supply power from the utility ’ s lines to the consumer ’ s weatherhead. For service at 1000 volts or less (phase to phase) at a conductor temperature of 75
MV Steel Wire Armoured Cable CU/XLPE/CTS/STA/PVC Flame-retardant Power Cable
MV Steel Wire Armoured Cable CU/XLPE/CTS/STA/PVC Flame-retardant Power Cable APPLICATION Industrial & Utility Power Distribution Underground & Trench Laying Flame-Retardant Environments High-Temperature & Corrosive Conditions Medium-Voltage Networks (Up to 35kV) CONSUCTRUCTION Conductor: Compacted conductors Conductor Shield: Semi conductive shielding material (below 500mm 2 ) Semi conductive tape+semi conductive shielding material (500 mm 2 and above) Insulation:
26/35kV AWA θωρακισμένο καλώδιο CU/XLPE/AWA/PVC/PE
26/35kV AWA Armoured Cable CU/XLPE/AWA/PVC/PE Sheathed Flame-retardant Power Cable Application The 26/35kV AWA (Aluminium Wire Armoured) copper conductor power cable is designed for medium voltage power transmission and distribution systems up to 35kV. It is widely used in applications requiring high reliability, mechanical protection, and fire safety performance. Main Construction Conductor: Compacted conductors Insulation: PVC Metal Screen: Copper Tape Armouring: Aluminium
XLPE Μόνωση 4 πυρήνες θερμότητας ανθεκτικό καλώδιο Flame Retardant Power Cable OEM
XLPE Insulation Fire Resistant Cable Flame Retardant sheath Power cable 4 Core Application Fire resistant cables can be used in several critical buildings where safety against fire is mandatory to reduce the risk of death as: Hospitals & Old people’shomes. Schools & Recreational buildings. Museums & Historical places. Undergrounds & Tunnels. Railways & Airports. Shopping Centers & Malls. Theatres & Cinemas. Hotels & Offices. High-rise buildings Construction C ondu
240 -2000MM2 66kV καλώδιο υψηλής τάσης CU XLPE CAS PE PVC LSHF υπόγειο καλώδιο
240 -2000 MM2 66V High Voltage Cable CU/XLPE /CAS/PE PVC LSHF Underground Cable Application Used for underground power transmission lines; laid on cable ladder, tray, buried direct in the ground or in duct in the ground Construction 1.Conductor 2.Conductor screen 3.XLPE insulation 4.Insulation screen 5.Semiconducting tape 6.Aluminum corrugated sheath 7.PE or PVC outer sheath (Graphite coating or extruded semiconducting) Description Voltage Rating (Uo/U)(Um) : 36/66 kV