underground armored cable
"
SWA Acciaio filo blindato XLPE cavo di alimentazione, XLPE cavo elettrico Logo personalizzato
SWA Steel Wire Armored XLPE Insulated Power Cable CU/PVC/LSZH Application The cables are for instrumentation and control equipment in tooling machinery, production lines, and flexible applications with free movement without tensile load. Suitable for use in dry, ambient and wet rooms. The screen protects against external interference pulses for interference-free transmission. These cables are not used for outdoor or underground installation Characteristics Voltage Rating: Uo
CU XLPE STA PVC MV cavo sotterraneo IEC standard 18/30kV cavo a media tensione
CU/XLPE/SWA/PVC Medium Voltage Cable 18/30kV IEC Standard Underground Cable Application The cables are suitable for installation mostly in power supply stations, indoors and in cable ducts, outdoors, underground as well as for installation on cable trays for industries, switchboards and power stations Construction Conductor: Class 2 Aluminium/Copper circular, stranded Conductor Screen: Semi-conductive XLPE (Cross-Linked Polyethylene) Insulation : XLPE (Cross-Linked Polyethyle
Cavo XLPE blindato a filo d' acciaio a singolo nucleo, cavo a media tensione a conduttore di rame
Copper Conductor XLPE Insulated Power Cable Cu/XLPE/PVC/SWA Medium Voltage Cable Application XLPE (Cross-Linked Polyethylene) insulated cables are widely used in power transmission and distribution systems due to their high thermal resistance, mechanical strength, and excellent electrical insulation properties. They are commonly applied in medium- to high-voltage networks, underground and submarine installations, industrial plants, and commercial or residential buildings.
Cavo di controllo elettrico blindato N2XBY XLPE Cavo di controllo isolato CU/XLPE/STA/PVC
Armoured Control Electrical Cable N2XBY XLPE Insulated Control Cable CU/XLPE/STA/PVC APPLICATION This product is suitable for use in control, monitoring circuits, and protection circuits in circuits with a rated voltage of 450/750V and below CONSTRUCTION Conductor: C ircular solid copper conductor (A) or circular stranded copper conductor (B) Insulation: Polyvinyl chloride (PVC) Filler: Polypropylene (PP) m esh f illing r ope Armouring: Galvanized steel tape Outer sheath:
Cavo MV ABC in media tensione isolato in XLPE da 19/33kV con schermo in filo di rame
19/33kV Screened Medium Voltage MV ABC Cable IEC 60502 Compliant 3X150mm + 1X50mm Configuration Applications Suitable for indoor/outdoor installations, cable trenches, tunnels, and underground or underwater deployments Used in power distribution networks, substations, and industrial plants requiring 19/33kV voltage levels Ideal for magnetic duct-free environments (single-core cables are restricted in magnetic ducts) Construction Conductor: Circular Compacted Stranded H68
Cavo di alimentazione multipolare con isolamento in XLPE, conduttore in rame, cavo ignifugo con isolamento in XLPE EN 60332
Multi Core XLPE Insulated Power Cable Cu Conductor Fire Proof Cable with XLPE Insulation EN 60332 APPLICATION Industrial Facilities Widely used in petrochemical plants, steel mills, and power stations due to its high-temperature resistance (up to 90°C continuous operation) and flame-retardant properties (compliance with IEC 60332-3-22 for group flame spread limits) High-Rise Buildings & Underground Installations Essential for fire safety in vertical shafts, cable
XLPE Cablo ad alta tensione isolato a singolo nucleo a tre nuclei PVC Shield 110kV OEM
XLPE Insulated High Voltage Cable Single Core Three Core PVC Shield 110kV Application Power Transmission and Distribution Renewable Energy Projects Industrial and Commercial Infrastructure Underground and Submarine Power Systems Railways and Transportation Systems Construction Conductor: Copper or aluminum for good conductivity Insulation: XLPE (cross-linked polyethylene) Shielding: Metallic or semi-conductive layers to prevent electrical interference Armor (optional):
Cable di conduttore in alluminio a fili resistente alla luce solare per l'ingresso del servizio sotterraneo
Stranded Aluminium Conductor Cable Sunlight Resistant For Underground Service Entrance APPLICATION Power Distribution Networks Building and Construction Commercial/Residential Wiring High-Rise Buildings Industrial Facilities Heavy Machinery Power Supply Renewable Energy Systems Transportation Infrastructure Railways and Airport E V Charging Stations CHARA C TERISTIC Voltage Rating Uo/U: 3.6/6 ( 7.2 ) kV , 6/6 ( 7.2 ) kV , 6/10(12)kV , 8.7/10(12kV ), 8.7/15(17.5)kV ,
STA cavo strumento blindato cavo per computer ignifugo
STA Shielded Instrument Cable Flame Retardant Computer Cable APPLICATION Industrial automation systems (PLC, DCS, SCADA) Power plants, chemical plants, and mining facilities Data centers and computer rooms requiring EMI shielding Underground or hazardous locations requiring flame retardancy CONSTRUCTION C onductor: The first or second type of copper conductor In s u lation: Low density polyethylene (LLDPE) Fill er (optional): Filling rope Separate shielding: Braided shielding