NF C 33-209 Kabel terpasang udara bersertifikat XLPE Terisolasi 0,6/1kV 3x150+1x95
| Application: | Jalur distribusi overhead | Cores Nos: | 1,2,3,4 lebih multicore |
| Rated Voltage: | 0.6/1KV | Installation Degree: | -20 ℃ -90 ℃ |
| Neutral Messengers: | AAC, AAAC atau ACSR | Insulation: | PE/PVC |
| High Light: | Kabel ABC bersertifikat NF C 33-209,Kabel Bundel Udara Berinsulasi XLPE,Kabel ABC 0 |
||
NF C 33-209 Kabel terpasang udara bersertifikat XLPE Terisolasi 0,6/1kV 3x150+1x95
Aplikasi
Primarily used for overhead service applications such as street lighting, outdoor lighting, andTo be used at voltages of 0.6/1kV and at conductor temperatures not to exceed 90°C for cross-linked polyethylene (XLPE) insulated conductors. Untuk digunakan pada tegangan 0.6/1kV dan pada suhu konduktor tidak melebihi 90°C untuk konduktor terisolasi dengan polietilena terikat silang (XLPE).
Konstruksi
Konduktor: Stranded, circular compacted, circular compressed AAC atau AAAC.
Isolasi: Cross-linked polyethylene (XLPE), warna hitam, tahan cuaca dan UV
Phase atau public lighting conductorSirkular kompak aluminium:
Konduktor netralSirkular atau compacted aluminium-alloy:
Pilot konduktorSolid, plain copper conductor (1.5mm)²)
Isolasi: Cross-linked polyethylene (XLPE), warna hitam, tahan cuaca dan UV
Semua inti terisolasi.
Standar
NF C 33-209
Spesifikasi
|
No of cores aBagian nd |
Tidak. dari kawat |
Nominal. ,PenguranganKetebalan |
Sekitar Diameter dari kabel |
Maksimal Dc. Resistensi di 20°C |
Sekitar berat badan |
|||
|
fase |
Neutral. |
fase |
Neutral. |
fase |
Neutral. |
|||
|
mm |
Tidak. |
Tidak. |
mm |
mm |
mm |
Oh, tidak.km |
Oh, tidak.km |
kg/km |
|
1x25 + 1x54.6 |
7 |
7 |
1.4 |
1.6 |
21.3 |
1.20 |
0.63 |
309 |
|
1x35 + 1x54.6 |
7 |
7 |
1.6 |
1.6 |
22.7 |
0.868 |
0.63 |
345 |
|
1x50 + 1x54.6 |
7 |
7 |
1.6 |
1.6 |
23.8 |
0.641 |
0.63 |
384 |
|
1x70 + 1x54.6 |
12 |
7 |
1.8 |
1.6 |
25.9 |
0.443 |
0.63 |
456 |
|
1x95 + 1x54.6 |
19 |
7 |
1.8 |
1.6 |
27.7 |
0.320 |
0.63 |
537 |
|
1x70 + 1x70 |
12 |
7 |
1.8 |
1.6 |
26.7 |
0.443 |
0.50 |
491 |
|
1x95 + 1x70 |
19 |
7 |
1.8 |
1.6 |
28.5 |
0.320 |
0.50 |
571 |
|
1x120 + 1x70 |
19 |
7 |
1.8 |
1.6 |
29.7 |
0.253 |
0.50 |
643 |
|
1x120 + 1x95 |
19 |
19 |
1.8 |
1.6 |
31.9 |
0.253 |
0.343 |
737 |
|
1x150 + 1x95 |
19 |
19 |
1.8 |
1.6 |
33.6 |
0.206 |
0.343 |
819 |
|
3x25 + 1x54.6 |
7 |
7 |
1.4 |
1.6 |
23.5 |
1.20 |
0.63 |
508 |
|
3x35 + 1x54.6 |
7 |
7 |
1.6 |
1.6 |
26.1 |
0.868 |
0.63 |
619 |
|
3x50 + 1x54.6 |
7 |
7 |
1.6 |
1.6 |
28.1 |
0.641 |
0.63 |
733 |
|
3x70 + 1x54.6 |
12 |
7 |
1.8 |
1.6 |
31.9 |
0.443 |
0.63 |
951 |
|
3x95 + 1x54.6 |
19 |
7 |
1.8 |
1.6 |
35.2 |
0.320 |
0.63 |
1192 |
|
3x70+1x70 |
12 |
7 |
1.8 |
1.6 |
32.4 |
0.443 |
0.50 |
986 |
|
3x95 + 1x70 |
19 |
7 |
1.8 |
1.6 |
35.6 |
0.320 |
0.50 |
1227 |
|
3x120+1x70 |
19 |
7 |
1.8 |
1.6 |
37.8 |
0.253 |
0.50 |
1441 |
|
3x120+1x95 |
19 |
19 |
1.8 |
1.6 |
39.1 |
0.253 |
0.343 |
1536 |
|
3x150 + 1x95 |
19 |
19 |
1.8 |
1.6 |
42.2 |
0.206 |
0.343 |
1779 |
Hubungi kami untuk rincian lebih lanjut




FAQ
1. Berapa jangka waktu pembayaran kita?
Istilah pembayaran kami adalah T / T 30% terlebih dahulu, kemudian saldo dibayar sebelum mengambil barang atau L / C pada saat melihat.
2- Berapa waktu pengiriman?
Waktu pengiriman biasanya 7-30 hari kerja.
3- Apa paket kabel?
Paket biasanya drum kayu atau baja drum kayu atau kumparan. juga sesuai dengan kebutuhan pelanggan.
4. Bisakah kita menyediakan sampel gratis untuk pelanggan?
Tentu, kami menyediakan sampel gratis untuk pelanggan untuk memeriksa.
Ya, bisa mencetak nama perusahaanmu.
-
Ca new design cable for our projects, good quality
-
Tperfect