Kabel Tahan Api Bebas Halogen NXXH N2XH-J N2XH-O
| Usage: | Sistem Kontrol Akses | Insulation: | XLPE-PE PVC |
| Voltage: | 0.6/1KV | Length: | Disesuaikan |
| Conductor Material: | Tembaga | Packing: | Pengemasan karton netral atau disesuaikan |
| High Light: | Kabel tahan api bebas halogen,Kabel tahan api NXXH,Kabel tahan api N2XH-J |
||
Kabel tahan api bebas halogen NXXH N2XH-J N2XH-O
Aplikasi & Karakteristik
1. Seri Kabel N2XH
-
Aplikasi Utama:
-
Unit pengolahan petrokimia (jaket reaktor, kolom destilasi)
-
Sistem conveyor pabrik baja (zona tungku tinggi, rolling mill)
-
Kabel ruang mesin pesawat ruang angkasa
-
-
Karakteristik Teknis:
-
Suhu operasi terus menerus: -40°C sampai +250°C
-
Halogen-free flame retardant (sesuai dengan IEC 60332-3C)
-
Ketahanan minyak/bahan bakar (per ASTM D471)
-
Isolasi polyethylene terikat silang (XLPE)
-
2. Model Kabel N2XH-J
-
Fitur Khusus:
-
Jaket yang ditingkatkan secara mekanis untuk aplikasi yang rentan terhadap getaran
-
Perisai EMI (pengurangan 85dB @ 1GHz)
-
Desain multiconductor fleksibel (hingga 50 inti)
-
-
Penugasan Tipikal:
-
Perangkat pengujian otomotif (dinamometer powertrain)
-
Peralatan pengolahan wafer semikonduktor
-
Transmisi sinyal kereta api berkecepatan tinggi
-
3. Model Kabel N2XH-O
-
Keuntungan Unik:
-
Konduktor tembaga bebas oksigen (99,99% kemurnian)
-
Sifat tahan radiasi (10 ^ 6 Gy toleransi)
-
Lapisan penghalang kelembaban untuk aplikasi laut
-
-
Kasus Penggunaan Kritis:
-
Sirkuit kontrol fasilitas nuklir
-
Sistem pengikat ROV laut dalam
-
Instrumen pabrik kriogenik
-
Konstruksi
1. Struktur Kabel N2XH
-
Konduktor: Biasanya terdiri dari tembaga atau aluminium kemurnian tinggi, dipanaskan untuk fleksibilitas dan ketahanan rendah.
-
Isolasi: Isolasi polietilen terikat silang (XLPE) memberikan ketahanan termal yang sangat baik (hingga 90 °C) dan kekuatan dielektrik.
-
Perisai: Pita tembaga konsentris atau perisai perban meminimalkan gangguan elektromagnetik (EMI).
-
Jaket: Bahan termoplastik atau termoresist (misalnya, PVC atau LSZH) menawarkan ketahanan abrasi dan tahan api.
2Struktur Kabel N2XH-J
-
Konduktor: Mirip dengan NXXH tetapi mungkin termasuk stranding tambahan untuk fleksibilitas yang ditingkatkan.
-
Isolasi: XLPE dengan tegangan pemecahan dielektrik yang lebih tinggi, cocok untuk aplikasi tegangan tinggi industri.
-
Perisai: Perisai kawat baja atau pita melindungi terhadap tekanan mekanik (misalnya, kerusakan tikus atau menghancurkan).
-
Jaket luar: Diperkuat dengan benang serat kaca atau aramid untuk kekuatan tarik di lingkungan yang keras.
3Struktur Kabel N2XH-O
-
Konduktor: Tembaga dengan plating perak untuk peningkatan konduktivitas di lingkungan korosif.
-
Isolasi: Isolasi karet silikon untuk ketahanan suhu ekstrim (-60°C sampai +200°C).
-
Perisai: Pelindung dua lapisan (foil aluminium + perban tembaga) untuk perlindungan EMI yang unggul.
-
Jaket: Fluoropolimer (misalnya, PTFE) tahan terhadap sinar UV, bahan kimia, dan kelembaban, ideal untuk instalasi di luar ruangan.


Parameter
Dimensi- Jumlah inti X Potongan |
Desain | Pembangunan individu menjaga pengendali aman |
Peraturan luar diameter |
ketebalan isolasi |
kerang ketebalan |
Resistensi terhadap Tetaplah pengendali aman pada 20°C |
Berat Cu | berat badan dari kabel |
| bernomor | tentang | bernomor | bernomor | Max. | tentang | |||
| Nx mm2 | nx mm | mm | mm | mm | Q/km | kg/km | kg/km | |
| 1x1,5 | RE | 1x1,38 | 54 | 138 | 15 | 1,210 | 15,403 | 43 |
| 1×4 | RE | 1 x 2,25 | 64 | 225 | 20 | 461 | 5,869 | 75 |
| 1 x 16 | RM | 7x1,70 | 91 | 500 | 36 | 115 | 1,464 | 202 |
| 1 × 25 | RM | 7x2,13 | 11 | 610 | 48 | 727 | 925 | 302 |
| 1 × 70 | RM | 19 x 2,17 | 15 | 1,010 | 84 | 268 | 341 | 745 |
| 1 × 95 | RM | 19 x 2,52 | 17 | 1,190 | 97 | 193 | 246 | 986 |
| 1 × 185 | RM | 37 x 2,52 | 23 | 1,620 | 172 | 991 | 126 | 1888 |
| 1 × 300 | RM | 61x2,50 | 28 | 2,060 | 234 | 601 | 77 | 2945 |
| 2x1,5 | RE | 1x1,38 | 9 | 138 | 38 | 1,210 | 15,403 | 120 |
| 2x2,5 | RE | 1x1,78 | 10 | 178 | 45 | 741 | 9,433 | 154 |
| 2 x 16 | RM | 7x1,70 | 16 | 500 | 106 | 115 | 1,464 | 563 |
| 2×25 | RM | 7x2,13 | 20 | 610 | 152 | 727 | 925 | 840 |
| 2x35 | RM | 7x2,52 | 22 | 720 | 179 | 524 | 667 | 1106 |
| 2×120 | RM | 37 x 2,03 | 36 | 1,300 | 423 | 153 | 195 | 3343 |
| 2x300 | RM | 61x2,50 | 55 | 2,060 | 939 | 601 | 77 | 8072 |
| 3x1,5 | RE | 1x1,38 | 9 | 138 | 44 | 1,210 | 15,403 | 135 |
| 3 x 2,5 | RE | 1x1,78 | 10 | 178 | 51 | 741 | 9,433 | 181 |
| 3×4 | RE | 1 x 2,25 | 11 | 225 | 60 | 461 | 5,869 | 242 |
| 3 x 10 | RE | 1 x 3,56 | 14 | 357 | 83 | 183 | 2,330 | 464 |
| 3 x 16 | RM | 7x1,70 | 17 | 500 | 122 | 115 | 1,464 | 697 |
| N2XH | ||||||||
| 3x35 | RM | 7x2,52 | 23 | 720 | 208 | 524 | 667 | 1393 |
| 3×50 | RM | 19 x 1,83 | 26 | 830 | 256 | 387 | 493 | 1847 |
| 3×70 | RM | 19 x 2,17 | 31 | 1,010 | 343 | 268 | 341 | 2666 |
| 3×95 | RM | 19 x 2,52 | 36 | 1,190 | 417 | 193 | 246 | 3535 |
| 3×120 | RM | 37x2,03 | 38 | 1,300 | 474 | 153 | 195 | 4322 |
| 3×185 | RM | 37x2,52 | 48 | 1,620 | 740 | 991 | 126 | 6742 |
| 3×300 | RM | 61 x 2,50 | 59 | 2,060 | 1,079 | 601 | 77 | 10522 |
Pabrik

Aplikasi



FAQ
1Apa itu kabel N2XH?
N2XH adalah kabel listrik tahan api bebas halogen standar Eropa (EN), di mana "N" menunjukkan api yang tidak menyebar dan "XH" menunjukkan isolasi polietilen terikat silang (XLPE).Penggantinya J/O membedakan antara versi konduktor kaku (Kelas 1) dan fleksibel (Kelas 5).
2Fitur utama kabel N2XH-J/O?
-
Keamanan kebakaran: FRNC (Flame Retardant Non-Corrosive) mengurangi emisi asap/gas beracun selama insiden kebakaran
-
Bahan: Konduktor tembaga + isolasi XLPE + LSOH (low smoke zero halogen)
-
Sertifikasi: Sertifikasi CE/TUV, sesuai dengan standar EN 60332-3, IEC 60754-1
3Aplikasi khas?
-
Bangunan umum (rumah sakit, hotel)
-
Fasilitas industri (fasilitas kimia/minyak)
-
Sistem transportasi (metro, kereta api)
4. tegangan peringkat & rentang suhu?
-
Tegangan nominal: 0,6/1kV
-
Suhu operasi: -40°C sampai +90°C (instal tetap)
-
Tahan terhadap sirkuit pendek: +250°C (5 detik maksimum)
5- Keamanan pemasangan?
-
Radius lentur minimum: 12 × diameter kabel
-
Hindari rute paralel dengan kabel tegangan tinggi (menjaga jarak ≥ 300mm)
-
Gunakan alat glanding yang tepat untuk mengakhiri perisai
6Bagaimana mengidentifikasi kelas konduktor?
-
N2XH-J: Konduktor padat kelas 1 (keras)
-
N2XH-O: Konduktor berantai kelas 5 (fleksibel)
7Keuntungan dari kabel PVC?
-
50% kepadatan asap yang lebih rendah dalam kebakaran (ujian IEC 61034)
-
Tidak ada gas halogen korosif (sesuai dengan IEC 60754-1)
8Rekomendasi pemeliharaan?
-
Uji tahan isolasi tahunan (> 20MΩ·km)
-
Pemeriksaan visual untuk kerusakan lapisan di lingkungan korosif