logo
Gevonden 347 producten voor "

xlpe power cable

"
Kwaliteit Stalen band STA Halogeenvrije kabel van lage rookkwaliteit Klasse 2 Leider N2X2Y Vlamvertrager Fabriek

Stalen band STA Halogeenvrije kabel van lage rookkwaliteit Klasse 2 Leider N2X2Y Vlamvertrager

Steel Tape STA Low Smoke Zero Halogen Cable Class 2 conductor N2X2Y Application Flame-retardant low-smoke zero-halogen (LSZH/LSOH) cables are widely applied in various critical scenarios due to their enhanced safety and environmental features: ‌Transportation Systems:Deployed in metro systems, light rail transit, and aviation facilities to ensure safe power transmission while minimizing toxic emissions during fire incidents ‌Public Infrastructure: Used in hospitals, schools,

Kwaliteit Laagspanningskabels 2x25 mm2 met aluminium kabel Fabriek

Laagspanningskabels 2x25 mm2 met aluminium kabel

2*25 LOW VOLTAGE ABC Aerial Bundled Cable Overhead 2*25 MM² Stranded Aluminium Cable Application: The ABC 2*25mm² cable (Aerial Bundled Cable) is designed for reliable and efficient low and medium voltage power distribution in overhead electrical systems. This cable is commonly used in urban, rural, and industrial environments for electrical power transmission and is known for its high safety standards , durability , and performance Construction Conductor : Aluminum

Kwaliteit Medium Voltage 11kV Aerial Bundled Cable ABC Overhead Transmission Cable Fabriek

Medium Voltage 11kV Aerial Bundled Cable ABC Overhead Transmission Cable

Medium Voltage 11kV Aerial Bundled ABC Cable Overhead Transmission Cable Application This product is suitable for overhead power lines that are easy to produce short circuit faults and safety hazards to humans and animals through dense forests and trees Construction Conductor : Aluminum (lightweight, cost-effective). Insulation :PE or PVC. Sheath : Typically low-smoke halogen-free (LSHF) compound for reduced toxicity and smoke emission during fires. Specifications No of cores

Kwaliteit 15kV 35kV ACSR Leider ABC Aerial Bundled Cable Medium Voltage Overhead Cable Fabriek

15kV 35kV ACSR Leider ABC Aerial Bundled Cable Medium Voltage Overhead Cable

15kV 35kV ACSR Conductor ABC Aerial Bundled Cable Medium Voltage Overhead Cable APPLICATION 1 phase:t o supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 1000 volts or lower at a conductor temperature of 75℃ maximum. 2 phase: t o supply power from the utility ’ s lines to the consumer ’ s weatherhead. For service at 1000 volts or less (phase to phase) at a conductor temperature of 75℃ maximum for polyethylen

Kwaliteit 1.5kV zonne-energie PV DC-kabel Klimaatbestand H1Z2Z2-K Zonnepaneel DC-draad Fabriek

1.5kV zonne-energie PV DC-kabel Klimaatbestand H1Z2Z2-K Zonnepaneel DC-draad

1.5kV DC PV Solar Cable Climate Resistance H1Z2Z2-K Application The cable is designed for connecting photovoltaic system components inside and outside of buildings and equipment with high mechanical requirements and extreme weather conditions.It has the characteristics of Climate resistance, UV resistance,aging resistance,and the service life is over 25years. Construction Conductor: Using multiple tin-plated soft copper wire stranded into insulation Insulation: Irradiation

Kwaliteit Brandbestendige STA-pantserkabel Multi-Core PVC-overkleding Fabriek

Brandbestendige STA-pantserkabel Multi-Core PVC-overkleding

Steel Tape Armoured STA Fire Resistant Flame Retardant PVC Sheathed Control Cable Application Suitable for indoor use, fixed installations, in public areas such as hospitals, hotels, shopping malls, airports, underground railway networks, tunnels, communication centres, and, in general, all places where it is required a high degree of protection of persons and assets or/and with a large number of people and electrical/electronic equipment. Characteristics Rated power

Kwaliteit Custom Logo ABC Aerial Bundled Overhead Cable PE Isolatie 3 Fase Elektrische Kabel Fabriek

Custom Logo ABC Aerial Bundled Overhead Cable PE Isolatie 3 Fase Elektrische Kabel

ABC Aerial Bundled Overhead Cable PE Insulation 3 Phase Electrical Cable Applicatiom ‌ Copper-shielded ABC (Aerial Bundled Cables) ‌ are primarily used in ‌ overhead power distribution systems ‌ where reliability, electromagnetic interference (EMI) resistance, and durability are critical Construction Characteristics Voltage Rating: 600V Insulation Material: XLPE for enhanced durability and resistance to heat and weather Conductor Material: Aluminum Structure: Overhead twisted

Kwaliteit Aluminiumdraad en staaldraad gewapende kabel NA2XRY Aluminiumgeleider IEC 60502-1 Fabriek

Aluminiumdraad en staaldraad gewapende kabel NA2XRY Aluminiumgeleider IEC 60502-1

Aluminium Wire and Steel Wire Armoured Cable NA2XRY Aluminium Conductor IEC 60502-1 Applications The cables is mainly used for low-voltage(0.6/1kV) underground power distribution in industrial, commercial, and infrastructure projects requiring mechanical protection. Construction 1. Conductor: Class 1 or Class2 aluminum 2. XLPE Insulation 3. Alumiunium Wire Armoured (single core )or Steel Wire Armoured(Multi core) 4. PVC or polyethylene sheath. Characteristics Voltage Rating

Kwaliteit Spaanse standaard RV-K industriële kabels Powerflex kabel UNE 21123-2 Fabriek

Spaanse standaard RV-K industriële kabels Powerflex kabel UNE 21123-2

Spanish Standard RV-K Industrial Cables Powerflex Cable UNE 21123-2 APPLICATION RV-K cable is a low-voltage flexible copper conductor cable commonly used for power distribution and internal wiring in residential, commercial, and industrial installations. It is designed for rated voltages of 0.6/1 kV and is widely used in environments requiring flexible, easy-to-install wiring. CONSTRUCTION Flexible plain copper strands: Strands to VDE-0295 Class-5, IEC 60228 Class-5 XLPE