logo
Gevonden 347 producten voor "

xlpe power cable

"
Kwaliteit XLPE geïsoleerde aluminiumkabel 3 kern gepantserde kabel Middenspanning 120mm 240mm Fabriek

XLPE geïsoleerde aluminiumkabel 3 kern gepantserde kabel Middenspanning 120mm 240mm

XLPE Insulated Aluminum Cable 3 Core Armoured Cable Medium Voltage 120mm 240mm APPLICATION The cables have the advantage of simplicity in construction, lightness in weight; convenience in application besides its excellent electrical, thermal, mechanical and anti-chemical corrosion properties. It can also be laid with no limitation of level difference along the route. mainly used in transmission and distribution lines because of its excellent electrical and physical properties

Kwaliteit 1000kcmil Aluminiumkabel 100% XLPE Geïsoleerd 25kV voor industriële of infrastructuurbelastingen Fabriek

1000kcmil Aluminiumkabel 100% XLPE Geïsoleerd 25kV voor industriële of infrastructuurbelastingen

1000kcmil Aluminium Cable 100% XLPE Insulated 25kV for Industrial or Infrastructure Loads Applications The cable is designed for medium-voltage primary distribution systems, suitable for heavy industrial loads and infrastructure projects requiring reliable high-capacity power transmission. Construction 1. Conductor: copper or aluminum. 2. Provide armored and unarmoured power cables. 3. Rated voltage Medium voltage: 6kV (um=7.2kv) -30kv (um=36kv) 4. PVC or polyethylene sheath.

Kwaliteit 35KV 1 Core Medium Voltage Cable XLPE Geïsoleerde 1x185 1x300 MV gepantserde kabel Fabriek

35KV 1 Core Medium Voltage Cable XLPE Geïsoleerde 1x185 1x300 MV gepantserde kabel

35KV Single Core Medium Voltage Cable XLPE Insulated 1x185 1x300 Construction 1. Conductor- aluminum or copper multiwire circular compacted . 2. Conductor screen - extruded of conductive peroxide cross-linked PE. 3.Insulation - peroxide cross-linked PE. 4. Insulation screen - extruded of conductive peroxide cross-linked PE. 5.Combined screen: 5.1 A layer of conductive paper tapes or conductive polymer tape with minimum thickness of 0.2 mm. 5.2. A layer of copper wires with a

Kwaliteit MV 18kV 30kV gewapende elektrische kabel Single Core 1X185mm2 Koperen geleider XLPE Geïsoleerd Fabriek

MV 18kV 30kV gewapende elektrische kabel Single Core 1X185mm2 Koperen geleider XLPE Geïsoleerd

MV 18/30kV Armored Electrical Cable Single Core 1X185mm2 Copper Conductor XLPE Insulated Construction Conductor: Circular compacted stranded Copper or aluminium Conductor screen: Extruded semi-conductive compound Insulation: XLPE Insulation screen: Extruded semi-conductive compound Metallic screen: Copper Wire Binder tape: non-hygroscopic material Inner covering(bedding): PVC Metallic armor: Galvanized steel tape Application It is used to transmit and distribute power in

Kwaliteit 19/33kV Nominale XLPE Geïsoleerde Middenspanning MV ABC Kabel met Koperdraadscherm Fabriek

19/33kV Nominale XLPE Geïsoleerde Middenspanning MV ABC Kabel met Koperdraadscherm

19/33kV Screened Medium Voltage MV ABC Cable IEC 60502 Compliant 3X150mm + 1X50mm Configuration Applications Suitable for indoor/outdoor installations, cable trenches, tunnels, and underground or underwater deployments Used in power distribution networks, substations, and industrial plants requiring 19/33kV voltage levels Ideal for magnetic duct-free environments (single-core cables are restricted in magnetic ducts) Construction Conductor: Circular Compacted Stranded H68

Kwaliteit XLPE geïsoleerde aluminium geleider kabel staaldraad gepantserde pvc schede 8,7kV 15kV Fabriek

XLPE geïsoleerde aluminium geleider kabel staaldraad gepantserde pvc schede 8,7kV 15kV

8.7/15kV Aluminium Conductor Cable Steel Wire Armoured XLPE Insulated PVC Sheath Cable Application Distribution and signalling power cable for static outdoor application (with protection against direct UV-irradiation), in ground, in water, within facilities, in cable canals, in concrete, in conditions requiring increased electric protection and protection against mechanical damages. Used in electric power plants, transformer stations, industrial plants, metropolitan networks

Kwaliteit XLPE geïsoleerde halogeenvrije kabel met een lage rookwaarde met een enkele kern van 1900 3300 V Fabriek

XLPE geïsoleerde halogeenvrije kabel met een lage rookwaarde met een enkele kern van 1900 3300 V

XLPE Insulated Low Smoke Zero Halogen Cable Amoured 1900 3300V Application Low smoke zero halogen cables are becoming more popular in military applications, aircraft, railway and maritime. This is because in these areas it is often difficult to ventilate in the event of a fire.. Besides, Low smoke halogen free material is also widely used in high pressure underground tunnels or track marking lines in railway system. when using them, reduces the possibility of harmful gases

Kwaliteit Afgeschermde enkelkernkabel Middenspanning PVC-overkleding N2XSRY N2XSERY Fabriek

Afgeschermde enkelkernkabel Middenspanning PVC-overkleding N2XSRY N2XSERY

Screened Single Core Medium Voltage Power Cables PVC Sheathed N2XSRY N2XSERY Application For laying indoors, in tunnel, cable trench, well or direct in ground, able to bear external mechanical forces and certain pulling force Construction Conductor: Class 2 Aluminium/Copper circular, stranded Conductor Screen: Semi-conductive XLPE (Cross-Linked Polyethylene) Insulation : XLPE (Cross-Linked Polyethylene) Insulation Screen : Semi-conductive XLPE (Cross-Linked Polyethylene)

Kwaliteit 1KV N2XY/NA2XY laagspanningselektrische kabel 3 kern 4 kern 5 kern IEC 60502-1 Fabriek

1KV N2XY/NA2XY laagspanningselektrische kabel 3 kern 4 kern 5 kern IEC 60502-1

1KV N2XY/NA2XY Low Power Cable CU/XLPE/PVC LSZH 3 Core 4 Core 5 Core IEC 60502-1 Application Laying indoors, in tunnel, fixed on the bracket, pipe and buried in the soil, the cable cannot bear external mechanical forces. Construction Conductor:Circular, solid, compacted or sector shaped stranded Copper or aluminum Insulation:XLPE Filler: Non-hygroscopic material Inner sheath: PVC Outer Sheath PVC Technical data The ambient temperature for installation: ≥ 0 ℃ . Maximum