logo
وجدت 379 منتجات لـ "

xlpe insulated cable

"
الجودة 10 AWG كابل الطاقة الشمسية الضوئية UL DC 2KV XLPE عزل الشمسية Pv سلك المصنع

10 AWG كابل الطاقة الشمسية الضوئية UL DC 2KV XLPE عزل الشمسية Pv سلك

10 AWG Solar Cable UL DC 2KV XLPE Insulation Applications Solar Panel Interconnection Roof-Mounted & Ground-Mounted Systems DC Side Wiring Battery Storage Integration Structure Conductor: Tinned copper (single-core, Class 5 flexible stranded wire). Insulation: PVC (Polyvinyl Chloride) – Provides electrical insulation and mechanical protection. Voltage Rating: Typically 450/750V (for low-voltage applications). Flexibility: Highly flexible due to fine-stranded conductors,

الجودة كابل عالي الأداء منخفض الجهد 3 Core 4 Core 5 Core CU/XLPE/PVC المصنع

كابل عالي الأداء منخفض الجهد 3 Core 4 Core 5 Core CU/XLPE/PVC

High Performance Low Voltage Cable 3 Core 4 Core 5 Core CU/XLPE/PVC Cable APPLICATION The cables are typically used in 0.6/1kV rated voltage circuits , the main applications include p ower transmission and distribution , Industrial Equipment and commercial building, and underground Distribution and harsh area etc. CONSTRUCTION Conductor: Class 2 stranded Copper conductor Insulation: Cross-Linked Polyethylene(XLPE) Outer sheath: Polyvinyl chloride (PVC) CHARACTERISTIC Voltage

الجودة كابل الطاقة الشمسية المعزولة XLPE الكهربائية PV الطاقة الشمسية لوحة سلك 1.5MM 2.5MM PV1-F المصنع

كابل الطاقة الشمسية المعزولة XLPE الكهربائية PV الطاقة الشمسية لوحة سلك 1.5MM 2.5MM PV1-F

XLPE Insulated Solar Cable Electric PV Wire 1.5MM 2.5MM PV1-F Application Solar cables are the designated cable used for rooftop PV installations. They are suitable for free hanging, movable, fixed installation and buried in ground in constructional covered systems indoor, outdoor or in hazard explosion areas, in industry and agriculture. Cable performance Properties such as moisture and heat resistance, high and low temperature resistance, acid and alkali resistance,ozone

الجودة كابل ACSR Core ABC الهوائي المجمّع XLPE معزول 10kV لخطوط الطاقة العلوية المصنع

كابل ACSR Core ABC الهوائي المجمّع XLPE معزول 10kV لخطوط الطاقة العلوية

ACSR Core ABC Aerial Bundled Cable XLPE Insulated 10kV for Service Drop Lines This overhead power cable is designed for service drop lines in challenging environments including dense forests and areas with potential safety hazards to people and animals. Application Suitable for overhead power lines and service drop lines passing through dense forests, trees, and other environments prone to short-circuit faults and potential safety hazards. Construction Conductor: Steel

الجودة كابل التيار المنخفض النحاسية السلكية الشاشة النحاسية النواة الواحدة 0.6 / 1kV الكابل عازل PVC المصنع

كابل التيار المنخفض النحاسية السلكية الشاشة النحاسية النواة الواحدة 0.6 / 1kV الكابل عازل PVC

Copper Wire Screen Low Voltage Cable Single Core 0.6/1kV PVC Insulated Cable APPLICATION Copper-shielded low-voltage cables are widely used in environments requiring reliable power transmission with electromagnetic interference (EMI) protection CONSTRUCTION Conductor:Circular, solid, compacted or sector shaped stranded Copper or aluminum Insulation:XLPE Filler: Non-hygroscopic material Screen: Copper Wire Binder tape:: Non-hygroscopic material Sheath PVC Characteristics Test

الجودة 2XS(FL) 2Y A2XS(FL) 2Y 110kV كابلات الجهد العالي تحت الأرض XLPE العزل المصنع

2XS(FL) 2Y A2XS(FL) 2Y 110kV كابلات الجهد العالي تحت الأرض XLPE العزل

110kV Single Core High Voltage Cable 1000 mm2 600 mm2 3130 mm Underground Transmission Cable Application The 110kV cable is widely used in ‌high-voltage power transmission and distribution systems‌, primarily serving the following applications: ‌Power station connections: Transmitting electricity from generators to substations or directly integrating into grid systems‌, Suitable for ‌underground installations‌ in complex terrains (e.g., mountainous regions) to ensure stable

الجودة كابل مدرع منخفض الجهد مقاوم للحريق 0.6/1kV CU/XLPE/STA/PVC كابل طاقة مثبط للهب من الفئة C المصنع

كابل مدرع منخفض الجهد مقاوم للحريق 0.6/1kV CU/XLPE/STA/PVC كابل طاقة مثبط للهب من الفئة C

Fire Resistant LV Armoured Cable 0.6/1kV CU/XLPE/STA/PVC Flame retardant Class C power cable Application This cable is widely used in ‌industrial and commercial buildings‌ where fire safety is critical. It is commonly installed in ‌power distribution systems‌, ‌emergency lighting circuits‌, and ‌fire alarm systems‌. Due to its flame-retardant properties and steel tape armour, it is suitable for ‌underground installations‌, ‌tunnels‌, and ‌areas with high mechanical stress‌.

الجودة كابل كهربائي متوسط الجهد بـ 35 كيلو فولت ذو 3 نواة مع عزل XLPE ودرع أسلاك الفولاذ لمشاريع الطاقة المصنع

كابل كهربائي متوسط الجهد بـ 35 كيلو فولت ذو 3 نواة مع عزل XLPE ودرع أسلاك الفولاذ لمشاريع الطاقة

3 Core 35kV Medium Voltage Power Cable Steel Wire Armoured Cable for Energy Projects Applications This 3-core 35kV medium voltage power cable is designed for power distribution networks in compliance with IEC standards. Suitable for fixed installation in ground, ducts, and open air environments. The steel wire armour (SWA) provides exceptional mechanical strength, enabling direct burial in areas subject to mechanical stress. Engineered for reliable performance in demanding

الجودة 3 Core XLPE Insulated Power Cable 0.6/1kV IEC 60502 90°C Rated for Industrial Underground Distribution المصنع

3 Core XLPE Insulated Power Cable 0.6/1kV IEC 60502 90°C Rated for Industrial Underground Distribution

تم تصنيعه وفقًا للمعيار IEC 60502، يوفر كابل الطاقة المعزول XLPE ثلاثي النواة هذا مع بنية CU/XLPE/PVC توزيعًا موثوقًا به 0.6/1 كيلو فولت عند 90 درجة مئوية متواصلة. مثالية لشبكات الطاقة الصناعية، وتركيب القنوات تحت الأرض، وأنظمة توزيع المباني.