pvc insulated cable
"
Cáp dẫn năng lượng mặt trời nhôm, 10,0mm2 Cáp hợp kim nhôm 1500V
Solar Aluminium Conductor Cable 10.0mm² Aluminium Alloy Cable Application Long distance wiring on the DC side: suitable for string connection to the DC side of the inverter, especially in large-scale power plants, which can significantly reduce material costs Fixed bracket system: suitable for ground photovoltaic arrays, requiring armor layer (such as steel strip) to resist mechanical damage High humidity/corrosive environment: Aluminum alloy has better chemical corrosion
Photovoltaic nhôm hợp kim dẫn dây cáp điện tùy chỉnh chiều dài
Photovoltaic Aluminium Conductor Cable Aluminum Alloy 8000 Series Conductor Application Application Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities. May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC Construction Phase conductor: Aluminum alloy conductor 8000
Dây điện bện linh hoạt bằng đồng mạ thiếc 2X12 AWG, cáp 2 lõi
Tinned Copper Flexible Stranded Electrical Wire 2X12 AWG 2 Core Cable APPLICATION Industrial equipment requiring high flexibility and durability, such as robotic arms and automated machinery. Power distribution systems where corrosion resistance is critical, especially in marine or humid environments Renewable energy installations (e.g., solar panel arrays) due to its excellent conductivity and tinned oxidation resistance. CONSTRUCTION AND SEPCIFICATION Conductor
Cáp ABC bó 5 ruột chịu ăn mòn và điện áp định mức 15/35kV dùng cho phân phối điện trên không
3 Phase Aerial Bundled ABC Cable 5 Core Designed for overhead power distribution systems with excellent corrosion resistance, offering superior safety, reliability, and cost-efficiency compared to traditional bare conductors. Applications Temporary Power Supply at Construction Sites Service Drop (Power Pole to Service Entrance) Secondary Cable (Pole-to-Pole) & Street Lighting Heavy-Duty Applications in Industrial Areas Medium-Voltage (MV) Distribution (15kV-25kV Systems)
Cáp liên kết trên không 3 * 70 Alu NFC 33-209 Cáp ABC
Overhead Aerial Bundled Cable 3*70 Alu NFC 33-209 ABC Cable Deatils Phase Conductor : Aluminium Conductor Neutral Conductor : AAAC(All Aluminium Alloy Conductor)Insulation : XLPE/PERated Voltage : 0.6/1KVCores : 1,2,3,4,5,2+1, 3+1 ,3+2, 4+1, 4+2 CoresOther Standards: ASTM/ BS 7870-5/ IEC 60502/AS/NZS or according to your requirement.Application: The aerial bundled cables designed for overhead distribution lines have all conductors made of aluminium, insulated with XLPE.Phase
Sợi nhôm và thép dây thép cáp bọc thép NA2XRY Aluminium Conductor IEC 60502-1
Aluminium Wire and Steel Wire Armoured Cable NA2XRY Aluminium Conductor IEC 60502-1 Applications The cables is mainly used for low-voltage(0.6/1kV) underground power distribution in industrial, commercial, and infrastructure projects requiring mechanical protection. Construction 1. Conductor: Class 1 or Class2 aluminum 2. XLPE Insulation 3. Alumiunium Wire Armoured (single core )or Steel Wire Armoured(Multi core) 4. PVC or polyethylene sheath. Characteristics Voltage Rating
Multi Core LSZH Low Smoke Zero Halogen Cable XLPE Sắt thép giáp
Multi Core Low Smoke Zero Halogen Cable XLPE Steel Wire Armoured Application For fixed installation of the transmission and distribution systems, tunnels and pipelines and other occasions .For situation not suppose to bear the external mechanical force. Constructions Conductor: Plain circular stranded copper conductor, conform to IEC 60228 class 2 Insulation: XLPE Amour: Steel Wire armour Core Conductor :annealed copper (stranded core) Popular sizes: 2~5 core x1.5~630mm²
KCMIL 400 500 Cáp hợp kim nhôm dòng AA8000 cho phân phối điện
KCMIL 400 500 Aluminium Conductor Cable AA8000 series Aluminum Alloy conductor Application Aluminum alloy cables (e.g., AA-8000 series per ASTM B800) are widely used in power distribution due to their lightweight, cost-effectiveness, and corrosion resistance. Key applications include: 1. Power Transmission & Distribution Building Wiring: Replace copper in residential/commercial circuits (NEC & IEC compliant). Utility Grids: Overhead lines and underground feeders (AA-1350/AA
Vải thép STA Cáp không chứa halogen khói thấp lớp 2 dẫn N2X2Y Khả năng chống cháy
Steel Tape STA Low Smoke Zero Halogen Cable Class 2 conductor N2X2Y Application Flame-retardant low-smoke zero-halogen (LSZH/LSOH) cables are widely applied in various critical scenarios due to their enhanced safety and environmental features: Transportation Systems:Deployed in metro systems, light rail transit, and aviation facilities to ensure safe power transmission while minimizing toxic emissions during fire incidents Public Infrastructure: Used in hospitals, schools,