xlpe power cable
"
66KV 69kv 110kv 132KV HV Kablosu XLPE Izolasyon Yüksek Voltaj Kablosu 1000MM2 1500MM2 2500M2
66KV 69kv 110kv 132KV HV Cable XLPE Insulation High Voltage Cable 1000MM2 1500MM2 2500M2 APPLICATION For laying indoors,in tunnel cable trench,well or direct in ground,able to bear external mechanical forces and certain pulling force. CONSTRUCTION Conductor: Stranded circular or segmental (Milliken) compacted copper conductor Conductor shield: Semi-conductive shield Insulation: Cross-Linked Polyethylene(XLPE) Insulation shield: Semi-conductive shield Metal shielding layer:
Üç Çekirdekli Orta Gerilim Kablosu XLPE/ PVC/ STA Yeraltı İletim kablosu
Three Core Medium Voltage Cable XLPE/ PVC/ STA Underground Transmission cable Construction Conductor: Round compacted conductors Conductor Shield: Semi conductive shielding material (below 500mm) Semi conductive tape+semi conductive shielding material (500 mm and above) Insulation: Polyvinyl chloride (PVC) Insulation Shield: Peelable semiconducting shielding material Metal Shield Layer: Copper Tape Copper Wire(35kV 500mm above) Filler: Polypropylene (PP) m esh f illing r ope
Orta Gerilim Düşük Duman Sıfır Halojen Kablo LSZH 19/33 (36)kV CU/XLPE/SWA/ LSZH EN60228
Medium Voltage Low Smoke Zero Halogen Cable LSZH 19/33 (36)kV CU/XLPE/SWA/ LSZH EN60228 APPLICATION For installation in ground, outdoors, indoors and in cable ducts forpower station, industry and distribution networks. CONSTRUCTION Conductor: Circular stranded, compacted copper conductor or aluminum conductor, class 2 Conductor Screen: Semi-conducting Compound Insulation: XLPE (Cross-linked polyethylene) Insulation Screen: Semi-conducting Compound Metallic Screen: Copper Tape
Alev geriletici düşük voltajlı kablo 4 çekirdek 0.6/1kV CU/XLPE/ STA/PVC endüstriyel kablo
Flame Retardant Low Voltage Cable 4 Core 0.6/1kV CU/XLPE/ STA/PVC Industrial Cable APPLICATION This product is suitable for use in circuits with a rated voltage not exceeding 0.6/1kV, for the purpose of power transmission and distribution. CONSTRUCTION Conductor: Class 1 or class 2 stranded Copper conductor Insulation: Cross-Linked Polyethylene(XLPE) Inner sheath: Polyvinyl chloride (PVC) Armour: Single core: Steel Tape Multi core: Galvanized Steel Tape Outer sheath:
Tek Damarlı AWA Zırhlı Kablo Orta Gerilim 36kV'a Kadar Kentsel Enerji Şebekeleri İçin
Single Core AWA Armoured Cable Medium Voltage up to 36kV for Urban Power Grids APPLICATION Single Core AWA (Aluminium Wire Armoured) Medium Voltage Cable is engineered with a lightweight aluminium wire armour layer, delivering excellent mechanical protection, corrosion resistance and flexible installation performance. Designed for medium voltage systems typically ranging from 3.6/6 kV to 26/35 kV , it is widely deployed in the following critical scenarios: Urban power grids
18kV SWA Zırhlı Alüminyum Alaşım Kondüktör Bakır Teyp Yeraltı Güç Dağıtımı için Koruma Kablosu
18kV SWA Armoured Aluminium Alloy Conductor Copper Tape Screened Cable for Underground Power Distribution Application The 18kV SWA Armoured Aluminium Alloy Conductor Copper Tape Screened Cable is primarily used for medium voltage underground power distribution systems. It is designed to deliver reliable electrical power in demanding environments where mechanical protection and electrical shielding are required. This cable is widely applied in: Urban power distribution
Bakır tel kalkanlı çelik bant zırhlı STA kablosu Orta gerilim 8.7/15kV MV güç kablosu
Copper Wire Shielded Steel Tape Armoured STA Cable Medium Voltage 8.7KV 15kV Copper Wire Shielded Medium Voltage Steel Tape Armoured STA Cable 8.7/15kV Applications Copper shielded cables, also known as shielded twisted pair (STP) or shielded coaxial cables, are widely used in various industries due to their ability to minimize electromagnetic interference (EMI) and radio frequency interference (RFI). Telecommunications Industrial Automation Medical Equipment Aerospace and
0.6/1KV LSOH AWA Aluminium Wire Armoured Electrical Cable Single Core IEC 60502-1
0.6/1KV LSOH AWA Aluminium Wire Armoured Electrical Cable Single Core IEC 60502-1 APPLICATION Fixed Wiring Power Mains: e.g., in buildings, stadiums, schools Harsh Environments: Cable trenches, tunnels, direct burial Special Sites: Subways, mines, industrial plants CONSTRUCTION Conductor: Class 1/ Class 2 stranded Copper conductor Insulation: XLPE Filler ( options): Polypropylene mesh tearing rope I nner sheath: Polyvinyl chloride (PVC) A rmour:Aluminium wire Outer sheath
Üç çekirdekli alüminyum iletken kablo Bakır bant kalkan çelik tel zırhlı kablo
Three Core Aluminium Conductor Cable Copper Tape Shield Steel Wire Armoured AA-8000 Series Cable Application Suitable for urban underground power grids, power station outgoing lines, internal power supply lines of industrial and mining enterprises, etc. Construction Conductor Conductor Shiel Insulation Metal Shield Layer Filler Binder Tape Armouring Outer sheath Specification YJLHV62 YJLHV22-18/30kV C able S tructure P arameters Specs mm² Conductor diameter mm Outer thickness