pvc insulated cable
"
IEC 60502 N2XH Düşük Duman Sıfır Halogen LSZH Kablo XLPE yalıtımlı 0.6KV 1kV
IEC 60502 N2XH Low Smoke Zero Halogen Cable XLPE Insulated 0.6/1kV Application Low smoke zero halogen cables are becoming more popular in military applications, aircraft, railway and maritime. This is because in these areas it is often difficult to ventilate in the event of a fire.. Besides, Low smoke halogen free material is also widely used in high pressure underground tunnels or track marking lines in railway system. when using them, reduces the possibility of harmful
CU XLPE PVC Düşük Voltajlı Güç Kablosu Bakır Tel Koruma Kablosu 0.6/1kV
CU/XLPE/PVC Low Voltage Cable Copper Wire Shielded Cable 0.6/1kV Application The cable could be laying indoors, in tunnel, cable trench, or direct in ground, they can bear external mechanical forces, but unable to bear large pulling force. Construction Conductor:Circular, solid, compacted or sector shaped stranded Copper or aluminum Insulation:XLPE Filler: Non-hygroscopic material Screen: Copper Wire Binder tape:: Non-hygroscopic material Sheath PVC Characteristics Test
Alüminyum alaşımlı iletkenli XLPE yalıtılmış orta gerilimli güç kabloları
Aluminium Alloy Conductor XLPE Insulated Power Cable Copper Wire Shield XLPE/PVC/STA Medium Voltage Application Used for tall building, Hospital, Theatre, Power station, Metro Tunnel or Petrochemical Industry or other special place required for low smoke , zero halogen clean and safe cable. Construction Conductor Conductor Shield Insulation Metal Shield Layer Filler Binder Tape Armouring Outer sheath Laying Method Pipe laying, trench laying, tunnel laying, vertical shaft and
400sqmm Tek çekirdek Alüminyum Güç Kablosu Zırhlı STA 35kV Cu XLPE PVC STA
400sq mm Single Core Aluminium Conductor Cable Armoured STA 35kV Cu/XLPE/PVC/STA Application Renewable Energy Systems : Widely used in solar farms and wind power projects due to lightweight design and corrosion resistance Industrial and Urban Infrastructure : Ideal for underground burial, tunnels, and industrial plants requiring durable, corrosion-resistant power distribution Transportation Networks : Deployed in subways, railways, and airports where flexibility and
NFC 33-209 Aerial Bundled Cable ABC PE XLPE yalıtımlı ABC Kablosu OEM
NFC 33-209 Stranded Aerial Bundled Cable PE/XLPE Insulated ABC Cable Application: XLPE insulated Aerial Bundled Cables For distributive low overhead network in the city, pros urban and rural areas. For supply of remote facilities and villages of temporary and permanent character.For above-ground house connections. Construction Conductor : Aluminum (lightweight, cost-effective). Insulation : XLPE (excellent thermal resistance, withstands temperatures up to 90°C ). Sheath :
Alev Geciktiricili Orta Gerilim Kablosu 12/20kV N2XSH Tek Damarlı Üç Damarlı
Flame-retardant Medium Voltage Cable 12/20kV N2XSH Single Core Three Core APPLICATION Suitable for power supply lines with flame retardant requirements, such as urban underground power grids, power station outgoing lines, and internal power lines of industrial and mining enterprises. CONSTRUCTION C onductor: Tightly press circular conductor Conductor shield: S emi conductive shielding material (below 500mm ² ) Semi conductive tape+semi conductive shielding material (500mm ²
Tinned Copper Wire Shield instrument Cable 2X10AWG 2X12AWG 2X16AWG
Tinned Copper Wire Shield instrument Cable 2X10AWG 2X12AWG 2X16AWG APPLICATION Telecommunications Networking Infrastructure Industrial Automation Audio-Visual Systems Transportation CONSTRUCTION AND SEPCIFICATION Conductor Material: Tinned Copper (Flexible Stranded) Number of Conductors: 102 strands Insulation: PVC Strand Diameter: 0.20 mm Shielding Layer: Polyester Tape + Aluminum Foil Flat Cable Specification: 10 strands × 0.20 mm Braid Layer: 128 strands × 0.10 mm FACTORY
Yeraltı güç dağıtımı için 3 çekirdekli ve LSZH'li yangın derecelendirilmiş düşük voltajlı kablo
Fire Rated Low Voltage Wire N2XY with 3 Core 1.5-400mm² Underground Power Cable Product Overview Fire Rated Low Voltage Wire with 3 Core 1.5-400mm² is engineered to maintain circuit integrity during fire conditions, ensuring continuous power supply for critical emergency systems. Applications This fire-resistant cable is specifically designed for critical systems including emergency lighting, fire alarms, and evacuation systems. Its three-core configuration (phase, neutral,
Özel Logo ABC Güç Kablosu 4 çekirdekli XLPE İzole 6.35/11kV Quadruplex UD Kablosu
Custom Logo ABC Power Cable 4 Core XLPE Insulated 6.35/11kV Quadruplex UD Cable This specialized cable is designed for high-performance power distribution in demanding environments, combining durability, safety, and branding customization. Application This specialized cable is designed for high-performance power distribution in demanding environments, combining durability, safety, and branding customization. Construction All aluminium conductor, polyethylene or cross linked