mv power cable
"
6.35kV 11kV MV XLPE Kablo Orta Voltajlı STA Güç Kablosu Elektrik İstasyonu için
6.35/11kV MV XLPE Insulated Power Cable Medium Voltage STA for Power Station Application Suitable for installations indoors: mostly in power supply stations and outdoors: in cable ducts, underground, and on cable trays for industries, switch-boards and power stations. Due to the good laying and mechanical characteristics, this cable is suitable when mechanical protection is required or in applications where mechanical damages are expected to occur Characteristics Voltage
ASTM Standart Havadan Bağlı ABC Güç Kablosu 15kV 35kV Havadan Dağıtım hattı için
ASTM Standard Aerial Bundled ABC Power Cable 15kV 35kV For Overhead Distribution Line APPLICATION Screened MV ABC cables are specialized power transmission solutions combining medium-voltage (MV) capabilities with the structural advantages of Aerial Bunch Cables (ABC). Their applications include: Medium-Voltage Distribution Networks Aerial Power Infrastructure Industrial Power Supply Renewable Energy Projects CONSTRUCTION Conductor: Circular Compacted Stranded H68
Alüminyum Alaşımlı İletken Orta Gerilim Güç Kablosu 3.6-35kV AL/XLPE/CWS/CTS/STA/PVC Güç Dağıtım Ağları için
Aluminium Alloy Conductor Medium Voltage Power Cable 3.6-35kV AL/XLPE/CWS/CTS/STA/PVC for Power Transmission AL/XLPE/STA/PVC for Power Transmission Application This high-performance medium voltage power cable is designed for reliable and efficient electrical transmission in industrial and commercial settings. Suitable for 3.6-35kV voltage applications in substations, industrial parks, and power distribution networks Construction Conductor: Class 2 Aluminium conductor
CU XLPE STA PVC MV Yeraltı Kablosu IEC Standart 18/30kV Orta Voltaj Kablosu
CU/XLPE/SWA/PVC Medium Voltage Cable 18/30kV IEC Standard Underground Cable Application The cables are suitable for installation mostly in power supply stations, indoors and in cable ducts, outdoors, underground as well as for installation on cable trays for industries, switchboards and power stations Construction Conductor: Class 2 Aluminium/Copper circular, stranded Conductor Screen: Semi-conductive XLPE (Cross-Linked Polyethylene) Insulation : XLPE (Cross-Linked Polyethyle
EAC Certificated MV Medium Voltage Cable CU/XLPE/STA/PVC Flame-retardant Power Cable
EAC Certificated MV Medium Voltage Cable CU/XLPE/STA/PVC Flame-retardant Power Cable APPLICATION Suitable for power supply lines with flame retardant requirements, such as urban underground power grids, power station outgoing lines, and internal power lines of industrial and mining enterprises. CONSUCTRUCTION C onductor: Tightly press circular conductor Conductor shield: S emi conductive shielding material (below 500mm ² ) Semi conductive tape+semi conductive shielding
35KV 1 çekirdek orta gerilimli kablo XLPE yalıtımlı 1x185 1x300 MV zırhlı kablo
35KV Single Core Medium Voltage Cable XLPE Insulated 1x185 1x300 Construction 1. Conductor- aluminum or copper multiwire circular compacted . 2. Conductor screen - extruded of conductive peroxide cross-linked PE. 3.Insulation - peroxide cross-linked PE. 4. Insulation screen - extruded of conductive peroxide cross-linked PE. 5.Combined screen: 5.1 A layer of conductive paper tapes or conductive polymer tape with minimum thickness of 0.2 mm. 5.2. A layer of copper wires with a
Bakır XLPE yalıtımlı SWA zırhlı güç kablosu MV Dış LSZH kablosu
Copper XLPE Insulated SWA Armoured Electrical Cable MV Outdoor LSZH Cable Application LSZH Medium Voltage cable with aluminium conductors offering a lightweight alternative to copper conductor alternatives. Suitable for use in conduit and for fixed, protected installation. For installations where fire, smoke emission and toxic fume create a potential risk to life and equipment. Characteristics Rated power-frepuency voltage U0/U: 3.6/6kv~26/35kv. Max.admissible operating
MV Steel Wire Armoured Cable CU/XLPE/CTS/STA/PVC Flame-retardant Power Cable
MV Steel Wire Armoured Cable CU/XLPE/CTS/STA/PVC Flame-retardant Power Cable APPLICATION Industrial & Utility Power Distribution Underground & Trench Laying Flame-Retardant Environments High-Temperature & Corrosive Conditions Medium-Voltage Networks (Up to 35kV) CONSUCTRUCTION Conductor: Compacted conductors Conductor Shield: Semi conductive shielding material (below 500mm 2 ) Semi conductive tape+semi conductive shielding material (500 mm 2 and above) Insulation:
Yüksek Performanslı MV ABC Kablosu 12.7/22kv 3x150+50mm
High Performance MV ABC Cable 12.7/22kv 3x150+50mm for Overhead Power Lines Deatils Phase Conductor : Aluminium Conductor Neutral Conductor : AAC/AAAC/ACSR Insulation : XLPE/PE Rated Voltage : 1-35KV Cores : 1,3 Cores Construction Specification UMBER OF CORES X NOMINAL CROSS SECTION PHASE CONDUCTOR MESSENGER SUSPENSION UNIT CONTINUOUS CURRENT RATING AT 300C AMBIENT TEMP STRANDING NOMINAL SECTIONAL AREA MAXIMUM CONDUCTOR RESISTANCE STRANDING NOMINAL SECTIONAL AREA BREAKING