logo
Encontrado 90 productos para "

overhead line conductor

"
Calidad AAAC Conductor desnudo - Todos los conductores de aleación de aluminio ASTM B 399 Norma 6201 T81 Fabricación

AAAC Conductor desnudo - Todos los conductores de aleación de aluminio ASTM B 399 Norma 6201 T81

AAAC Bare Conductor-All Aluminum Alloy Conductors ASTM B 399 Standard 6201 T81 APPLICATION Used as bare overhead conductor for primary and secondary distribution. Designed for utilizing a high-strength aluminum-alloy to achieve a high strength-to-weight ratio; affords good sag characteristics. (1...

Calidad Cable aéreo de carga aérea 3*70 Alu NFC 33-209 ABC Fabricación

Cable aéreo de carga aérea 3*70 Alu NFC 33-209 ABC

Overhead Aerial Bundled Cable 3*70 Alu NFC 33-209 ABC Cable Deatils Phase Conductor : Aluminium Conductor Neutral Conductor : AAAC(All Aluminium Alloy Conductor)Insulation : XLPE/PERated Voltage : 0.6/1KVCores : 1,2,3,4,5,2+1, 3+1 ,3+2, 4+1, 4+2 CoresOther Standards: ASTM/ BS 7870-5/ IEC 60502/AS...

Calidad ACSR Core ABC Aerial Bundled Cable XLPE aislado de 10 kV para líneas eléctricas aéreas Fabricación

ACSR Core ABC Aerial Bundled Cable XLPE aislado de 10 kV para líneas eléctricas aéreas

ACSR Core ABC Aerial Bundled Cable XLPE Insulated 10kV for Service Drop Lines This overhead power cable is designed for service drop lines in challenging environments including dense forests and areas with potential safety hazards to people and animals. Application Suitable for overhead power lines ...

Calidad Conductor de aleación de aluminio AAAC de resistencia térmica de 750 MCM para líneas eléctricas aéreas Fabricación

Conductor de aleación de aluminio AAAC de resistencia térmica de 750 MCM para líneas eléctricas aéreas

Thermal Resistant 750 MCM AAAC Aluminum Alloy Conductor Overhead Power Lines Application Used for overhead power lines, ground wires, steel stay wires Applicable standards: Aluminum alloy conductor (AAAC) are produced according to ASTM B-399, BS EN-50182, AS/NZS 1531, DIN 48201, CSA 61089, IEC 61089...

Calidad Alta tensión conductor aéreo de cobre desnudo sólido flexible 10~185mm2 Fabricación

Alta tensión conductor aéreo de cobre desnudo sólido flexible 10~185mm2

Solid Flexible Copper Bare Conductor Electric Grounding Cable Bare Copper Wire Application This high voltage bare copper conductor is used in overhead power transmission lines. It can also be used as bus line in power stations or other applications where high current carrying capacity is required. ...

Calidad Overhead Insulated ABC Cable NFC 33-209 0.6/1kV for Power Distribution Fabricación

Overhead Insulated ABC Cable NFC 33-209 0.6/1kV for Power Distribution

Overhead Insulated ABC Cable NFC 33-209 0.6/1kV for Power Distribution APPLICATION Overhead Power Distribution‌ Rural Electrification & Remote Areas‌ Industrial & Commercial Installations‌ Service Connections‌ Renewable Energy Projects‌ CONSTRUCTION Phase conductors: AAC Insulation: XLPE, UV...

Calidad Transmisión aérea Conductor desnudo AAC Conductor de aluminio completo 500 MCM Fabricación

Transmisión aérea Conductor desnudo AAC Conductor de aluminio completo 500 MCM

Overhead Transmission Bare Conductor AAC All Aluminum Conductor 500 MCM APPLICATION AAC is most commonly used in medium to long-distance overhead transmission and distribution lines. C ONSTRUCTION t is composed entirely of aluminum strands, which makes it lightweight, cost-effective, and highly ...

Calidad Conductor de aluminio desnudo de alto voltaje AAAC AAC ACSR para líneas de transmisión de energía Fabricación

Conductor de aluminio desnudo de alto voltaje AAAC AAC ACSR para líneas de transmisión de energía

Stranded Bare Conductors Aluminum Cable AAAC, AAC, ACSR High Voltage Application This stranded aac cable is used in high voltage overhead power transmission lines. Compared with ACSR of the same diameter, it has a smaller breaking load and is used in lines where short span and low resistance are ...

Calidad Conductor de cobre desnudo de 70 mm cuadrados para líneas eléctricas aéreas Fabricación

Conductor de cobre desnudo de 70 mm cuadrados para líneas eléctricas aéreas

70Sq.mm Cu. Bare Copper Conductor for Overhead Power Line Application Solid and stranded bare copper conductors are suitable for overhead transmission and distribution applications. Stranded conductors of greater flexibility are suitable for uninsulated hook up, jumpers and grounds in electrical ...