shielded power cable
"
3.6/6кВ 26/35кВ кабель среднего напряжения XLPE изоляционная металлическая лента бронепровод
3.6/6kV~26/35kV Medium Voltage Cable XLPE Insulation PVC Sheath Metal Tape Armouring Power Cable Application Suitable for urban underground power grids, power station outgoing lines, internal power supply lines of industrial and mining enterprises, etc. CONSTRUCTION Conductor: Round compacted conductors Conductor Shield: Semi conductive shielding material (below 500mm Semi conductive tape+semi conductive shielding material (500 mm 2 and above) Insulation: Polyvinyl chloride
STA бронированный MV кабель питания 8.7/15 кВ одноядерный XLPE ПВХ для строительства наземных подземных электростанций
STA Armored MV Power Cable 8.7/15kV Single Core XLPE PVC for Construction Overhead Underground Power Stations Application These cables have the advantage of simplicity in construction, lightness in weight; onvenience in application besides its excellent electrical, thermal, mechanical and anti-chemical corrosion properties. It can also be laid with no limitation of level difference along the route. Construction Conductor: Tightly press round conductor Conductor Screen: Semi
Подземное среднее напряжение 11кв 15кв 22кв 70мм-400 кв.м Алюминиевый бронированный кабель питания
Underground Medium Voltage 11kv 15kv 22kv 70mm-400 Sqmm Aluminium Armoured Power Cable Application The cables are designed for distribution of electrical power with nominal voltage Uo/U ranging from 1KV to 35KV and frequency 50Hz, as in power supply stations, indoors and in cable ducts, outdoors, underground. Construction Conductor: Class 2 Aluminium conductor Conductor: Semi-conductive shield Insulation: Cross-Linked Polyethylene(XLPE) Insulation shield: Semi-conductive
N2XS(F)2Y N2XSY Четырехъядерный MV кабель питания с медным проводником изолированный ПВХ
N2XS(F)2Y N2XSY Four Core MV Power Cable With Copper Conductor PVC Insulated APPLICATION The medium-voltage power cable is widely used in industrial and utility electrical networks. Its primary applications include: Power distribution systems : Transmits electrical energy in underground or cable-tray installations. Industrial plants : Supplies power to heavy machinery, transformers, and substations. Renewable energy projects : Integrates into wind farms, solar parks,
Распределение электроэнергии Промышленный электрический кабель 26/35 кВ AL/XLPE/CTS/STA/PVC YJLV22 NA2XSEBY
Power Distribution Industrial MV Power Cable 26/35kV AL/XLPE/CTS/STA/PVC YJLV22 NA2XSEBY Application 1. Underground and outdoor power networks2. Cable duct installations3. Industrial substations4. Commercial power distribution5. Renewable energy systems6. Mining and heavy industry7. Telecommunications infrastructure8. Smart grid deployments Construction Conductor: Class 2 Aluminium conductor Conductor: Semi-conductive shield Insulation: Cross-Linked Polyethylene(XLPE)
Огнеупорный MV-кабель CU/XLPE/CTS/CWS/SWA/FR-PVC для выходящей линии электростанции
Fire Resistant MV Power Cable CU/XLPE/CTS/CWS/SWA/FR-PVC Cable for Outgoing Line of Power Station Application This product is suitable for power supply lines with flame retardant requirements, such as urban underground power grids, power station outgoing lines, and internal power lines of industrial and mining enterprises. Construction Conductor: Tightly press round conductor Conductor Screen: Semi-conductive shield Insulation:XLPE Insulation shield: Semi-conductive shield
Кабель электропередачи 110 кВ ВВ с пожарной мощностью, соответствующий стандартам IEC 60840 и IEC 62067 для распределительных сетей
Fire Rated 110kV HV Power Cable with IEC 60840 and IEC 62067 Standards for Distribution Networks APPLICATION The cable is mainly used in underground, indoor, and tunnel installations requi ring fire resistance, and typically suitable in power plants, substations, and critical urban infrastructure. CONSTRUCTION Conductor: Stranded circular or segmental (Milliken) compacted copper conductor Conductor shield: Semi-conductive shield Insulation: Cross-Linked Polyethylene(XLPE)
Медная проволока защищенный ПВХ кабель питания стальной ленты бронированный одноядерный STA кабель
Copper Wire Shielded PVC Insulated Power Steel Tape Armoured Single Core STA Cable Application Copper Wire Shielded PVC Insulated cables combine copper braid/screen shielding (for EMI/RFI suppression) with PVC/XLPE insulation, offering durability, flexibility, and compliance with standards like IEC 60502 or BS 5467. They are ideal for low-voltage power distribution, control circuits, and instrumentation in EMI-prone or safety-critical environment Construction Conductor:
Single Core HV High Voltage Power Cable 2XS(FL)2Y CU/XLPE/CWS/STA/PVC
Single Core HV High Voltage Power Cable 2XS(FL)2Y CU/XLPE/CWS/STA/PVC APPLICATION Urban underground networks (e.g., substation connections, industrial power distribution) Harsh environments requiring robust mechanical and chemical protection CONSTRUCTION Conductor: Stranded circular or segmental (Milliken) compacted copper conductor Conductor shield: Semi-conductive shield Insulation: Cross-Linked Polyethylene(XLPE) Insulation shield: Semi-conductive shield Metal