pvc insulated industrial cables
"
ASTM Standard Aerial Bundled ABC Power Cable 15 кВ 35 кВ для воздушных распределительных линий
ASTM Standard Aerial Bundled ABC Power Cable 15kV 35kV For Overhead Distribution Line APPLICATION Screened MV ABC cables are specialized power transmission solutions combining medium-voltage (MV) capabilities with the structural advantages of Aerial Bunch Cables (ABC). Their applications include: Medium-Voltage Distribution Networks Aerial Power Infrastructure Industrial Power Supply Renewable Energy Projects CONSTRUCTION Conductor: Circular Compacted Stranded H68
Огнеупорный кабель среднего напряжения 12/20 кВ N2XSH одноядерный трехядерный
Flame-retardant Medium Voltage Cable 12/20kV N2XSH Single Core Three Core APPLICATION Suitable for power supply lines with flame retardant requirements, such as urban underground power grids, power station outgoing lines, and internal power lines of industrial and mining enterprises. CONSTRUCTION C onductor: Tightly press circular conductor Conductor shield: S emi conductive shielding material (below 500mm ² ) Semi conductive tape+semi conductive shielding material (500mm ²
Огнестойкий низковольтный кабель с 3 жилами и LSZH для подземного распределения электроэнергии
Fire Rated Low Voltage Wire N2XY with 3 Core 1.5-400mm² Underground Power Cable Product Overview Fire Rated Low Voltage Wire with 3 Core 1.5-400mm² is engineered to maintain circuit integrity during fire conditions, ensuring continuous power supply for critical emergency systems. Applications This fire-resistant cable is specifically designed for critical systems including emergency lighting, fire alarms, and evacuation systems. Its three-core configuration (phase, neutral,
Tinned Copper Wire Shield instrument Cable 2X10AWG 2X12AWG 2X16AWG
Tinned Copper Wire Shield instrument Cable 2X10AWG 2X12AWG 2X16AWG APPLICATION Telecommunications Networking Infrastructure Industrial Automation Audio-Visual Systems Transportation CONSTRUCTION AND SEPCIFICATION Conductor Material: Tinned Copper (Flexible Stranded) Number of Conductors: 102 strands Insulation: PVC Strand Diameter: 0.20 mm Shielding Layer: Polyester Tape + Aluminum Foil Flat Cable Specification: 10 strands × 0.20 mm Braid Layer: 128 strands × 0.10 mm FACTORY
Сертификат EAC 0,6/1 кВ Низковольтный кабель питания VVg VVgng Огнеупорный кабель
EAC Certificated 0.6/1kV Low voltage Power Cable VVg VVgng Flame-retardant Cable APPLICATION The cable is designed for fixed electrical installations in industrial and nuclear power plants, ensuring safe energy transmission under AC voltage (0.66/1/3 kV, 50 Hz) or DC voltage (1/1.5/4.5 kV). CONSTRUCTION Conductor: Class 1/ Class 2 stranded Copper conductor Insulation: Polyvinyl chloride (PVC) Filler ( options ): Polypropylene mesh tearing rope Outer sheath: Polyvinyl
MV AWA бронированный электрический кабель 3.6/6 кВ 26/35 кВ AL/XLPE/AWA/SWA/LSZH
MV AWA Armoured Electrical Cable 3.6/6kV~26/35kV AL/XLPE/AWA/ SWA/LSZH Customized Length APPLICATION Widely used in industrial power grids, energy infrastructure, underground substations, and cross-border power engineering projects CONSTRUCTION Conductor : Aluminium Insulation :XLPE Filler : LSZH Armour :Single core: AWA (Aluminium wire armour) All other sizes: SWA (Galvanized round steel wire) Sheath : LSZH STANDARD EN 60502-2 CHARACTERISTICS Voltage Rating Uo/U: 3. 8 /6 .6
Ультрафиолетоустойчивые кабели средней напряженности с алюминиевым проводником для распределительных сетей 12/20 кВ
UV Resistant Medium Voltage Cables with Aluminoum Conductor for Distribution Networks 12/20kV Application This type of cable is primarily used for power transmission and distribution in medium-voltage power systems, making it suitable for urban grids, industrial and mining enterprises, and infrastructure projects where high power supply reliability is required. Construction Conductor: Class 2 Aluminium conductor Conductor: Semi-conductive material Insulation:XLPE Insulation
Медная лента экрана стальной проволоки бронированный кабель SWA 35 кВ высокое напряжение
Copper Tape Screen Steel Wire Armoured Electrical Cable SWA 35kV High Voltage Application Power Transmission Networks Renewable Energy Systems Industrial Facilities Urban Grid Upgrades Special Environments Construction Conductor Class 2 copper conductor or Aluminium , compacted or segment strand Milliken Conductor Screen: Extruded semi-conductive XLPE (Cross-Linked Polyethylene) Insulation XLPE (Cross-Linked Polyethylene) Insulation Screen: Extruded Semi-conductive XLPE
Среднее напряжение низкое дымовое галогенное питание кабель 18/30 36кВ 19/33 36кВ 3 ядра
Medium Voltage Low Smoke Zero Halogen Cable 18/30 36kV 19/33 36 KV 3 Core Application Industrial Automation & Process Control : Hazardous Environments Public Infrastructure Building Management Systems Transportation Networks Renewable Energy Characteristics LSZH sheathing resists flame spread and reduces smoke density. Copper/aluminum shielding ensures signal accuracy in noisy environments. Halogen-free construction aligns with IEC 60092 , IEEE 802.3