pvc insulated industrial cables
"
Три ядра кабеля среднего напряжения XLPE/ PVC/ STA подземный кабель передачи
Three Core Medium Voltage Cable XLPE/ PVC/ STA Underground Transmission cable Construction Conductor: Round compacted conductors Conductor Shield: Semi conductive shielding material (below 500mm) Semi conductive tape+semi conductive shielding material (500 mm and above) Insulation: Polyvinyl chloride (PVC) Insulation Shield: Peelable semiconducting shielding material Metal Shield Layer: Copper Tape Copper Wire(35kV 500mm above) Filler: Polypropylene (PP) m esh f illing r ope
3-жильный силовой кабель среднего напряжения от 6 кВ до 35 кВ, бронированный кабель среднего напряжения
6kV to 35kV 3-Core MV Power Cable, Armored Medium Voltage Cable APPLICATION Medium voltage 3-core cables (typically rated from 6 kV to 36 kV) are widely used in power distribution networks due to their balanced phase loading, compact design, and enhanced reliability compared to single-core alternatives. Urban & Industrial Distribution:Deployed in substations, factories, and commercial complexes to transmit power with reduced electromagnetic interference (EMI). Preferred for
Многопарный компьютерный кабель для экранированных приборов (индивидуально и общим экраном)
Individual and Overall Shielded Instrument Cable Multi Pair Computer Cable APPLICATION The cable is suitable for electronic computers and automation instruments with high anti-interference requirements for rated voltage of 500V and below CONSTRUCTION C onductor: The first or second type of copper conductor In s u lation: Low density polyethylene (LLDPE) Fill er (optional): Filling rope Separate shielding: Braided shielding (P) O verall shield: Braided shielding (P) Outer
30 кВ MV подземный бронированный электрический кабель 1 * 50 мм2 CU SWA XLPE PVC
30KV MV Underground Armoured Electrical Cable 1*50mm² CU SWA XLPE PVC APPLICATION This cable is specifically designed for the distribution of electrical power in medium voltage networks. Its robust construction makes it ideal for direct burial underground in a wide range of industrial, commercial, and utility applications, including: Public Power Distribution Networks : Supplying power from substations to residential and commercial areas. Industrial Plants : Powering heavy
N2XC2Y IEC60502 LV кабель медной проводник XLPE изоляция PE кабель питания оболочки
N2XC2Y IEC60502 LV Cable Copper Conductor XLPE Insulation PE Sheath Power Cable APPLICATION For outdoor installation, in the ground, for power stations, industry and distribution boards or subscriber networks, where protection against contact voltage is required in the case of mechanical damage. The core insulation of XLPE allows a higher operating temperature than comparable cable with PVC core insulation. The cables are halogen-free, UV-resistant and particularly resistant
Медный ленточный щит Среднее напряжение бронированный кабель 6 кВ 10 кВ 600 кв.
Copper Tape Shield Medium Voltage 6/10kV Steel Tape Armoured 600sq Underground Use Construction Conductor: Circular compacted stranded Copper or aluminium Conductor screen: Extruded semi-conductive compound Insulation: XLPE Insulation screen: Extruded semi-conductive compound Metallic screen: Copper Wire Binder tape: non-hygroscopic material Inner covering(bedding): PVC Metallic armor: Galvanized steel tape Application Suitable for urban underground power grids, power station
19/33кВ номинальное XLPE изолированное среднее напряжение MV ABC кабель с медной проволокой экрана
19/33kV Screened Medium Voltage MV ABC Cable IEC 60502 Compliant 3X150mm + 1X50mm Configuration Applications Suitable for indoor/outdoor installations, cable trenches, tunnels, and underground or underwater deployments Used in power distribution networks, substations, and industrial plants requiring 19/33kV voltage levels Ideal for magnetic duct-free environments (single-core cables are restricted in magnetic ducts) Construction Conductor: Circular Compacted Stranded H68
Кабель Triplex UD ABC, воздушный пучок проводов ABC 19/33 кВ, экранированный кабель среднего напряжения по IEC 60502
Triplex UD Cable ABC Aerial Bundled Cables 19/33kV Screened MV Cable to IEC 60502 APPLICATION Triplex UD Cable ABC Aerial Bundled Cables 19/33kV Screened cable is primarily used in overhead power distribution networks for transmitting electrical energy. It is designed for aerial installation and is suitable for medium-voltage applications (19kV to 33kV). The cable features a screened design to enhance electromagnetic compatibility and reduce interference. It is
Среднее напряжение MV 26/35 КВ Алюминиевый кабель питания Медная лента Щит ПВХ
Medium Voltage 26/35 kV Aluminium Conductor Cable Copper Tape Shield PVC Sheath Application Medium-voltage aluminum alloy cables are used in power distribution and industrial systems where lightweight design, cost efficiency, and corrosion resistance are critical Key applications include: Urban/Suburban Grids : Overhead or underground power distribution (1–35 kV) for residential/commercial areas, reducing installation costs vs. copper. Industrial Power Networks :