armoured power cable
"
Силовой кабель с алюминиевой жилой, одножильный, кабель среднего напряжения для подземной прокладки, для электротехнических целей
Single Core Aluminium Conductor Power cable Medium Voltage Underground Cable for Electrical Use APPLICATION Single-core aluminium conductor power cables with medium voltage ratings (typically 6kV–36kV) are widely used in the following scenarios Power Distribution Networks Industrial Facilities Infrastructure Projects Renewable Energy CONSTRUCTION Conductor: Round compacted conductors Conductor Shield: Semi conductive shielding material (below 500mm2 ) Semi
Кабель силовой низковольтный 0.6/1 кВ, трехжильный, сечением от 1.5 мм² до 400 мм², сертифицированный EAC
Three Core 0.6/1kV Low voltage Power Cable 1.5mm2 to 400mm2 EAC Certified Cable APPLICATION Three Core 0.6/1kV Low Voltage Power Cable with EAC certification is designed for: Underground installations in commercial/residential power distribution systems, utilizing durable PVC/XLPE insulation for environmental protection Industrial applications such as construction sites and power stations, where armored variants (e.g., SWA) provide mechanical strength Low-voltage networks
0.6/1кВ XLPE Изолированный кабель питания N2XY N2X2Y Сертифицированный EAC огнеупорный кабель питания
0.6/1kV XLPE Insulated Power Cable N2XY N2X2Y EAC Certified Flame-retardant Power Cable APPLICATION Fixed installations in power distribution networks, industrial plants, and urban infrastructure Flame-retardant applications requiring compliance with IEC 60331 and EAC safety standards Indoor/outdoor use in cable trunking, underground ducts, or direct burial, withstanding temperatures from -60°C to +200°C EMC protection in industrial environments due to its
Огнеупорный MV-кабель CU/XLPE/CTS/CWS/SWA/FR-PVC для выходящей линии электростанции
Fire Resistant MV Power Cable CU/XLPE/CTS/CWS/SWA/FR-PVC Cable for Outgoing Line of Power Station Application This product is suitable for power supply lines with flame retardant requirements, such as urban underground power grids, power station outgoing lines, and internal power lines of industrial and mining enterprises. Construction Conductor: Tightly press round conductor Conductor Screen: Semi-conductive shield Insulation:XLPE Insulation shield: Semi-conductive shield
STA бронированный MV кабель питания 8.7/15 кВ одноядерный XLPE ПВХ для строительства наземных подземных электростанций
STA Armored MV Power Cable 8.7/15kV Single Core XLPE PVC for Construction Overhead Underground Power Stations Application These cables have the advantage of simplicity in construction, lightness in weight; onvenience in application besides its excellent electrical, thermal, mechanical and anti-chemical corrosion properties. It can also be laid with no limitation of level difference along the route. Construction Conductor: Tightly press round conductor Conductor Screen: Semi
1kv CU XLPE ПВХ низковольтный кабель питания 1x70sqmm IEC60502-1 LV кабель
1kv CU/XLPE/PVC Low Voltage Power Cable 1x70sqmm IEC60502-1 Application 1kv CU/XLPE/PVC Low Voltage Power Cable 1x70sqmm IEC60502-1 UNE 21123 are used for electricity supply in low voltage installation system. They are suitable for installation in indoors and outdoors, in cable ducts, in power and switching stations, local energy distributions, industrial plants, where there is have many movings. Construction Conductor: Class 1 or class 2 stranded Copper conductor Insulation
ААК Алюминиевый проводник кабеля XLPE/PVC/STA Среднее напряжение питания кабеля 8,7 15 кВ
AAC Aluminium Conductor Cable XLPE/PVC/STA Medium Voltage Power Cable 8.7 15kV APPLICATION Suitable for urban underground power grids, power station outgoing lines, internal power supply lines of industrial and mining enterprises, etc. CONSTRUCTION Conductor: Round compacted conductors Conductor Shield: Semi conductive shielding material (below 500mm ) Semi conductive tape+semi conductive shielding material (500 mm and above) Insulation: Polyvinyl chloride (PVC) Insulation
Стандартные 10 кв.м. 16 кв.м. низковольтные кабели NYY-J NYY-O
Flame retardant LV Low Voltage Cable 0.6/1kV CU/ XLPE/STA/PVC Class C power cable APPLICATION This product is suitable for use in circuits with a rated voltage not exceeding 0.6/1kV, for the purpose of power transmission and distribution. CONSTRUCTION Conductor: Class 1 or class 2 stranded Copper conductor Insulation: Cross-Linked Polyethylene(XLPE) Inner sheath: Polyvinyl chloride (PVC) Armour: Single core: Steel Tape Multi core: Galvanized Steel Tape Outer sheath: Polyvinyl
26/35 кВ 3 ядра огнеупорный алюминиевый проводник кабель питания для фотоэлектрического проекта
26/35kV 3 Core Fire Resistant Aluminium Conductor Power Cable for Photovoltaic Project Overview The 26/35kV 3 Core Fire Resistant Aluminium Conductor Power Cable for Photovoltaic Projects is engineered for medium-voltage power transmission in utility-scale solar farms, renewable energy substations, and photovoltaic distribution systems. Designed for harsh outdoor environments and critical power continuity applications, this cable combines excellent electrical performance,