logo
Найдено 230 продукты для "

aluminum conductor cable

"
Качество ARE4H5E HD620 18/30KV кабель средней напряженности Алюминиевый проводник XLPE изоляционный пи пи жакет Фабрика

ARE4H5E HD620 18/30KV кабель средней напряженности Алюминиевый проводник XLPE изоляционный пи пи жакет

ARE4H5E HD620 18/30KV Medium Voltage Cable Aluminum Conductor XLPE Insulation PE Jacket APPLICATION For fixed installation applications in indoor or outdoor environments, including aerial, direct burial, and indirect burial. CONSUCTRUCTION Conductor: Aluminium Conductor Screen:Semi-conductive material Insulation: XLPE (Cross-Linked Polyethylene) Insulation Screen:extruded semiconducting compound (bonded) Longitudinal semiconducting water blocking tape. ScreenZ: :Aluminium

Качество ПВХ изоляционный воздушный кабель алюминиевый проводник ABC кабель питания Фабрика

ПВХ изоляционный воздушный кабель алюминиевый проводник ABC кабель питания

PVC Insulation Aerial Bundled Cable Aluminum Conductor ABC Application Use in aerial bundled conductor (ABC) systems for city power grid transmission line.Operating voltage up to 600/1000 volts.Main for overhead single-phase and three-phase electricity distribution and other purposes.Stable working temperature -10°C to 80°C. Construction Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or XLP crosslinked polyethylene.

Качество Электрический кабель из алюминия 600V 1000V алюминиевый проводник Фабрика

Электрический кабель из алюминия 600V 1000V алюминиевый проводник

XLPE Insulated Aluminium Conductor Cable AA- 8000 Series Conductor 600/1000V Application TypeXHHW-2MC cable is suitable for use as branch,feeder and service power distribution.It is suitable for use in wet or dry locations at temperature not to exceed 90°C.If it should be directly buried in the earth,MC cable with PVC sheathis an optimal choice.Maximum voltage rating for XHHW-2 application is 600Volts . Construction Type XHHW-2 conductors which is constructed with 8000 Series

Качество Высоковольтный обнаженный алюминиевый проводник AAAC AAC ACSR для линий электропередачи Фабрика

Высоковольтный обнаженный алюминиевый проводник AAAC AAC ACSR для линий электропередачи

Stranded Bare Conductors Aluminum Cable AAAC, AAC, ACSR High Voltage Application This stranded aac cable is used in high voltage overhead power transmission lines. Compared with ACSR of the same diameter, it has a smaller breaking load and is used in lines where short span and low resistance are required. Description Code name Item Application AAC All-aluminium Conductor Mainly for overhead power transmission and primary and secondary distribution AAAC All Aluminimum Alloy

Качество Кабель низкого напряжения, небронированный алюминиевый силовой кабель NA2XY, одножильный Фабрика

Кабель низкого напряжения, небронированный алюминиевый силовой кабель NA2XY, одножильный

Low Voltage Cable Non-Armoured Aluminum Power Cable NA2XY Single Core APPLICATION NA2XY cables are widely used in low voltage power distribution and electrical systems across multiple industries. The key applications include: Building and Construction, Industrial Facilities, Infrastructure, utilities and s pecial environments etc. CONSTRUCTION 1. Conductor: Compact aluminium 1350, class 2. 2. Insulation: Cross linked polyethylene XLPE. 3. Outer sheath: Polyvinyl chloride PVC

Качество 1 кВ ПЭ ПВХ изоляционная антенна ABC кабель алюминиевый проводник воздушный кабель Фабрика

1 кВ ПЭ ПВХ изоляционная антенна ABC кабель алюминиевый проводник воздушный кабель

600V ABC Aerial Bundled Cable Prefabricated 4X35 XLPE Insulation Standard Cable Application: This product is suitable for overhead power lines that are easy to produce short circuit faults and safety hazards to humans and animals through dense forests and trees Construction Conductor : Aluminum (lightweight, cost-effective). Insulation :PE or PVC. Sheath : Typically low-smoke halogen-free (LSHF) compound for reduced toxicity and smoke emission during fires. Specifications LV

Качество Электрический кабель из фотоэлектрического алюминиевого сплава Фабрика

Электрический кабель из фотоэлектрического алюминиевого сплава

Photovoltaic Aluminium Conductor Cable Aluminum Alloy 8000 Series Conductor Application Application Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities. May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC Construction Phase conductor: Aluminum alloy conductor 8000

Качество Наземная передача голый проводник AAC Все алюминиевый проводник 500 MCM Фабрика

Наземная передача голый проводник AAC Все алюминиевый проводник 500 MCM

Overhead Transmission Bare Conductor AAC All Aluminum Conductor 500 MCM APPLICATION AAC is most commonly used in medium to long-distance overhead transmission and distribution lines. C ONSTRUCTION t is composed entirely of aluminum strands, which makes it lightweight, cost-effective, and highly resistant to corrosion CHARA C TERISTIC Lightweight Corrosion Resistance Cost-Effective High Conductivity SPECIFICATION ominal cross-sectional area mm2 Actual cross-sectional area mm2

Качество IEC AAC Голый проводник Все алюминиевые проводники Наверху 100 мм 125 мм Фабрика

IEC AAC Голый проводник Все алюминиевые проводники Наверху 100 мм 125 мм

IEC AAC Bare Conductor All Aluminum Conductor Overhead 100mm 125mm Application AAC (All Aluminium Conductor) cable is widely used in overhead power transmission and distribution systems. Its key applications include: Power Distribution Networks – Suitable for urban and rural power lines due to its lightweight and corrosion resistance. Overhead Transmission Lines – Used in medium-voltage lines where conductivity and durability are required. Coastal/Humid Areas – Resistant to