aluminum conductor cable
"
Сертифицированный СИП по стандарту NF C 33-209 с изоляцией из сшитого полиэтилена 0.6/1 кВ 3x150+1x95
NF C 33-209 Certified Aerial Bundled Cable XLPE Insulated 0.6/1kV 3x150+1x95 Application Primarily used for overhead service applications such as street lighting, outdoor lighting, and temporary service for construction. To be used at voltages of 0.6/1kV and at conductor temperatures not to exceed 90°C for cross-linked polyethylene (XLPE) insulated conductors. Construction Conductor : Stranded, circular compacted, circular compressed AAC or AAAC. Insulation : Cross-linked
110 кВ высоковольтный электрический кабель с медным проводником, изолированный XLPE, бронированный SWA, IEC 60840
110kV High Voltage Power Cable – Copper Conductor, XLPE Insulated, SWA Armoured, IEC 60840 Underground Transmission & Substation Feeder Solution Designed for critical 110kV transmission networks , this single-core or three-core copper conductor power cable delivers high-capacity power flow from primary substations to heavy load centers. Manufactured under strict compliance with IEC 60840 (Power cables with extruded insulation for rated voltages 30kV to 150kV), this cable
Стальная лента бронированный STA низковольтный кабель с двумя ядрами XLPE изолированный CU AL проводник
Steel Tape Armoured STA Low Voltage Cable Two Core XLPE Insulated CU AL Conductor Application This XLPE insulated steel tape armored power cable is used in underground power transmission lines of rated voltage 1KV and below. Steel tape armor allows the power cable to bear considerable vertical pressures. Construction Conductor: Circular, solid, compacted or sector shaped stranded Copper or aluminum Insulation: Cross-linked polyethylene (XLPE). Inner covering:PVC Armouring:
240 -2000MM2 66кВ высоковольтный кабель CU XLPE CAS PE PVC LSHF подземный кабель
240 -2000 MM2 66V High Voltage Cable CU/XLPE /CAS/PE PVC LSHF Underground Cable Application Used for underground power transmission lines; laid on cable ladder, tray, buried direct in the ground or in duct in the ground Construction 1.Conductor 2.Conductor screen 3.XLPE insulation 4.Insulation screen 5.Semiconducting tape 6.Aluminum corrugated sheath 7.PE or PVC outer sheath (Graphite coating or extruded semiconducting) Description Voltage Rating (Uo/U)(Um) : 36/66 kV
Среднее напряжение 11 кВ воздушный кабель ABC воздушный кабель передачи
Medium Voltage 11kV Aerial Bundled ABC Cable Overhead Transmission Cable Application This product is suitable for overhead power lines that are easy to produce short circuit faults and safety hazards to humans and animals through dense forests and trees Construction Conductor : Aluminum (lightweight, cost-effective). Insulation :PE or PVC. Sheath : Typically low-smoke halogen-free (LSHF) compound for reduced toxicity and smoke emission during fires. Specifications No of cores
1.5-400 мм низковольтный кабель трехъядерный медный проводник ПВХ изолированный небронированный кабель питания
1.5-400mm Low Voltage Cable Three Core Power Cable Copper Conductor PVC Insulated Unarmored Power Cable CONSTRUCTION Conductor: Circular, solid, compacted or sector shaped stranded Copper or aluminum Insulation: PVC Filler: non-hygroscopic material Binder tape: non-hygroscopic material Sheath: PVC CHARACTERICSTIC Test Voltage: 3.5kV 5min No Breakdown The ambient temperature for installation: ≥0℃. Maximum conductor temperature in normal operation:≤90℃. Max operating temperatur
450/750V Медный проводник кабель управления ПВХ изоляция ПВХ оболочка ПВХ плетеный экранированный кабель
450/750V Copper Conductor Control Cable PVC Insulation PVC Sheath Braided Shielded Cable APPLICATION Copper braid shielded cables are widely used in industries that require reliable signal transmission, noise immunity, and electromagnetic interference (EMI) protection. Below are key applications: 1. Industrial Automation & Control Systems Used in PLC (Programmable Logic Controller) systems, motor control circuits, and industrial machinery. Ensures stable transmission of
Трехжильный алюминиевый бронированный кабель с изоляцией из ПВХ, стальной ленточной броней и оболочкой из ПВХ, низкого напряжения 600/1000В
Three core Stranded Aluminium Armored cable AL/PVC/STA/PVC Low Voltage 600/1000V Applications The cable is designed for fixed installation where mechanical protection and cost efficiency are required, such as industrial power distribution, buildings, underground installation, street power supply and etc. Construction 1. Conductor: Stranded aluminum 2. PVC Insulation 3. Steel Tape or Steel Wire Armoured. 4. PVC or polyethylene sheath. 5. Number of cable cores: three cores
XLPE изолированный высоковольтный кабель одноядерный трехядерный ПВХ щит 110 кВ OEM
XLPE Insulated High Voltage Cable Single Core Three Core PVC Shield 110kV Application Power Transmission and Distribution Renewable Energy Projects Industrial and Commercial Infrastructure Underground and Submarine Power Systems Railways and Transportation Systems Construction Conductor: Copper or aluminum for good conductivity Insulation: XLPE (cross-linked polyethylene) Shielding: Metallic or semi-conductive layers to prevent electrical interference Armor (optional):