logo
products

8.7/15kV XLPE Insulated Copper Power Cable with CWS SWA PVC for Underground Installation

기본 정보
원래 장소: 중국 허베이
브랜드 이름: Armoured Cable
인증: CCC,ISO,TUV,CE, EAC
모델 번호: YJV32 N2XSERY
최소 주문 수량: 협상 가능
가격: 협상 가능
포장 세부 사항: 롤, 나무 드럼, 스틸 드럼, 릴 또는 맞춤형
배달 시간: 다른 수량에 따라 7-30일
지불 조건: L/C, T/T, 웨스턴 유니온
공급 능력: 주당 100km
상세 정보
단열: XLPE, XLPO 기준: DIN 학사 IEC
난연성: 외장재: PVC/PE
지휘자: 구리 정격전압: 8.7/15kV
갑옷: SWA 핵심이 없습니다:

제품 설명

8.7/15kV XLPE Insulated Copper Power Cable with CWS SWA PVC for Underground Installation



Product Overview

The 8.7/15kV copper conductor power cable is designed for medium voltage power distribution systems. It adopts XLPE insulation combined with copper wire screen (CWS), steel wire armour (SWA), and a PVC outer sheath to provide stable electrical performance and mechanical protection.

This cable structure is suitable for fixed installations where reliability and durability are required under medium voltage operating conditions.

Construction

  • Conductor: Stranded copper conductor (Class 2)
  • Conductor Screen: Semi-conductive layer
  • Insulation: XLPE (cross-linked polyethylene)
  • Insulation Screen: Semi-conductive layer
  • Metallic Screen: Copper wire screen (CWS)
  • Armour: Steel wire armour (SWA)
  • Outer Sheath: PVC

Key Features

  • XLPE insulation with stable electrical and thermal characteristics
  • Copper conductor with low electrical resistance
  • Copper wire screen for controlled electric field distribution
  • Steel wire armour providing resistance to mechanical impact
  • PVC sheath suitable for outdoor and underground conditions
  • Designed for fixed installation in medium voltage systems

8.7/15kV XLPE Insulated Copper Power Cable with CWS SWA PVC for Underground Installation 08.7/15kV XLPE Insulated Copper Power Cable with CWS SWA PVC for Underground Installation 1

Applications

This cable is suitable for use in medium voltage distribution networks:

  • Underground power distribution lines
  • Substation feeder connections
  • Industrial and infrastructure power systems
  • Utility distribution networks
  • Cable ducts and trench installations

Technical Specifications

  • Rated Voltage: 8.7/15kV
  • Conductor: Copper, stranded (Class 2)
  • Insulation: XLPE
  • Metallic Screen: Copper wire screen
  • Armour: Steel wire armour
  • Sheath: PVC
  • Installation Method: Underground / duct / tray
  • Reference Standard: IEC 60502-2 (or equivalent)

Electrical & Mechanical Performance

The XLPE insulation ensures stable dielectric performance under operating conditions, while the copper conductor supports efficient current transmission. The copper wire screen contributes to electric field control and provides a path for fault currents. The steel wire armour enhances mechanical protection during installation and service.

Installation Considerations

  • Suitable for direct burial with proper bedding and backfilling
  • Can be installed in ducts or cable trenches
  • Bending radius should comply with standard requirements
  • Metallic screen should be properly earthed

Typical Use Case

In a medium voltage distribution project, this cable can be installed between substations and load centers. The armoured structure allows underground routing, while the screened design supports stable system operation.


Specification


Specs
mm²

Conductor diameter
mm

Nominal  thickness of insulation
mm

Outside diameter of insulation
±1.0mm

Nominal thickness of sheath
mm

Approximate outer diameter of cable
mm

Approximate cable weight
kg/km

3×25

6.0

4.5

17.0

2.6

56.6

4922

3×35

7.0

4.5

18.0

2.7

59.0

5468

3×50

8.2

4.5

19.2

2.8

62.1

6142

3×70

10.0

4.5

20.8

2.9

65.9

7152

3×95

11.6

4.5

22.6

3.1

70.2

8359

3×120

13.0

4.5

24.0

32

73.6

9440

3×150

14.4

4.5

25.4

3.3

78.2

11422

3×185

16.1

4.5

27.2

3.4

82.5

12966

3×240

18.4

4.5

29.4

3.6

87.9

15221

3×300

20.6

4.5

31.6

3.8

93.3

17636

3×400

23.4

4.5

34.4

4.0

99.9

20887


8.7/15kV XLPE Insulated Copper Power Cable with CWS SWA PVC for Underground Installation 2

8.7/15kV XLPE Insulated Copper Power Cable with CWS SWA PVC for Underground Installation 3

8.7/15kV XLPE Insulated Copper Power Cable with CWS SWA PVC for Underground Installation 4

8.7/15kV XLPE Insulated Copper Power Cable with CWS SWA PVC for Underground Installation 5

FAQ


1. Do your cables meet international standards?

Yes, our cables comply with IEC, BS, DIN, and other global standards.

2. Are your cables suitable for underground use?

Yes, armored cables are ideal for direct burial and duct installation.

3. Do you offer customized cables?

Yes, we support custom sizes, materials, and voltage ratings.

4. What certifications do you have?

We provide ISO, CE, and IEC test reports.

5. How do you ensure quality?

All cables undergo strict testing before delivery.

6. What is your delivery time?

Typically 7–30 days depending on order quantity.


평점 및 리뷰

전체 등급

5.0
이 공급업체에 대한 50개의 리뷰를 기반으로 합니다.

등급 스냅샷

다음은 모든 평점의 분포입니다.
5 별
100%
4 별
0%
3 별
0%
2 별
0%
1 별
0%

모든 리뷰

A
A*s
Sri Lanka Nov 12.2025
fast delivery and good quality, so as the service
K
K*n
Vietnam Nov 10.2025
really good support and professional
N
N*
Kazakhstan Sep 16.2025
Professional factory and fast delivery, a pleasant cooperation
연락처 세부 사항
Cai

전화 번호 : +8618991159926

왓츠앱 : +8619829885532