logo
products

6/10kV Double GST Armoured Cable 3X70mm2+1X10mm2 VEVBbShv for Mine Networks

기본 정보
원래 장소: 중국 허베이
브랜드 이름: Double GST Armoured Cable
인증: ISO,CCC,CE,TUV
모델 번호: YJV22
최소 주문 수량: 협상 가능
가격: 협상 가능
포장 세부 사항: 나무 드럼
배달 시간: 10일 근무일
지불 조건: 신용장, 티/티
공급 능력: 주당 100km
상세 정보
단열재: XLPE 도체 재료: 구리
재킷: PVC 정격전압: 6/10kV
장갑: 이중 GST 기갑 케이블 화면: 구리 테이프

제품 설명

6/10kV Double GST Armoured Cable 3X70mm2+1X10mm2 VEVBbShv for Mine Networks



APPLICATION 

The 6/10 kV Double GST Armoured Cable is a high-performance medium voltage power cable designed for reliable power transmission and distribution in demanding industrial and infrastructure environments. Featuring double galvanized steel tape (GST) armour, it provides excellent mechanical protection, making it ideal for direct burial and installation in harsh conditions. This cable is widely used in underground power distribution networks, industrial plants, mining operations, tunnel projects, power stations, and substations, as well as urban infrastructure systems. With robust XLPE insulation and a durable PVC outer sheath, it ensures long service life, resistance to moisture and chemicals, and stable electrical performance. It is an ideal solution for applications requiring safety, durability, and efficiency.

CONSTRUCTION 

Conductor: Tightly press circular conductor 

Conductor shield:Semi conductive shielding material 

Earth conductor:Copper multi-wire twisted without insulation or split, consisting of several wires. 

Insulation:Cross-linked polyethylene(XLPE) 

Insulation shielding:Peelable semiconducting shielding material 

Metal shielding layer:Copper Tape 

Filler:Non hygroscopic filling rope 

Armor:Galvanized steel tape 

Inner and outer sheaths:90 ℃ flame retardant polyvinyl chloride(PVC)


6/10kV Double GST Armoured Cable 3X70mm2+1X10mm2 VEVBbShv for Mine Networks 06/10kV Double GST Armoured Cable 3X70mm2+1X10mm2 VEVBbShv for Mine Networks 1


CHARACTERISTIC

 

Voltage Rating Uo/U:6kV

Maximum operating temperature of conductor:+90℃

Operating ambient temperature:-50℃~+50

Cable laying temperature:Not less than 0℃(When the ambient temperature is below 0℃, the cable should be preheated.) 

Minimum Bending Radius:10D (D is the actual outer diameter of the cable)

STANDARD

IEC60502-2,  EN 60228:2015,  GB/T12706


PARAMETER

Specs
mm²

Main conductor diameter
mm

Outside diameter of insulation
±1.0mm

Approximate outer diameter of cable
mm

Approximate cable weight
kg/km

3×50+1X10

7.6±0.2

17.2

47.5

3737

3×70+1x10

9.2±0.2

18.8

51.3

4575

3×95+1x10

10.9±0.2

20.5

55.2

5550



6/10kV Double GST Armoured Cable 3X70mm2+1X10mm2 VEVBbShv for Mine Networks 2

6/10kV Double GST Armoured Cable 3X70mm2+1X10mm2 VEVBbShv for Mine Networks 3

6/10kV Double GST Armoured Cable 3X70mm2+1X10mm2 VEVBbShv for Mine Networks 4

6/10kV Double GST Armoured Cable 3X70mm2+1X10mm2 VEVBbShv for Mine Networks 5

6/10kV Double GST Armoured Cable 3X70mm2+1X10mm2 VEVBbShv for Mine Networks 6


FAQ


1. What are the main types of power cables you manufacture?

We manufacture a wide range of power cables, including low voltage (LV), medium voltage (MV), and high voltage (HV) cables, as well as armoured cables, XLPE insulated cables, PVC insulated cables, and control cables. Our products comply with international standards such as IEC, BS, and ASTM. 

2. What is the difference between XLPE and PVC insulated cables?

XLPE insulated cables offer higher temperature resistance, better electrical performance, and longer service life compared to PVC cables. XLPE cables are widely used in medium and high voltage power transmission, while PVC cables are typically used for low voltage applications. 

3. What is armoured cable and where is it used?

An armoured cable is designed with a protective steel layer (such as steel tape armour or steel wire armour) to provide mechanical protection. It is commonly used for underground installation, industrial plants, power distribution networks, and harsh environments. 

4. What standards do your cables comply with?

Our cables are manufactured in accordance with international standards such as IEC 60502, IEC 60228, BS 5467, BS 6724, ASTM, and other customized standards based on project requirements. We also provide third-party testing and certification upon request. 

5. How to choose the right cable size for my project?

Choosing the correct cable size depends on several factors, including current carrying capacity, voltage level, installation method, ambient temperature, and voltage drop requirements. Our technical team can assist you in selecting the most suitable cable for your application.


평점 및 리뷰

전체 등급

5.0
이 공급업체에 대한 50개의 리뷰를 기반으로 합니다.

등급 스냅샷

다음은 모든 평점의 분포입니다.
5 별
100%
4 별
0%
3 별
0%
2 별
0%
1 별
0%

모든 리뷰

C
C*r
Namibia Sep 18.2025
a new design cable for our projects, good quality
N
N*
Kazakhstan Sep 16.2025
Professional factory and fast delivery, a pleasant cooperation
T
T*l
Philippines Aug 21.2025
perfect
연락처 세부 사항
Cai

전화 번호 : +8618991159926

왓츠앱 : +8619829885532