발견 294 제품 "

xlpe insulated wire

"
품질 IEC 60502 N2XH 저연소 제로 할로겐 LSZH 케이블 XLPE 단열 0.6KV 1kV 공장

IEC 60502 N2XH 저연소 제로 할로겐 LSZH 케이블 XLPE 단열 0.6KV 1kV

IEC 60502 N2XH Low Smoke Zero Halogen Cable XLPE Insulated 0.6/1kV Application Low smoke zero halogen cables are becoming more popular in military applications, aircraft, railway and maritime. This is because in these areas it is often difficult to ventilate in the event of a fire.. Besides, Low smoke halogen free material is also widely used in high pressure underground tunnels or track marking lines in railway system. when using them, reduces the possibility of harmful

품질 IEC 60502-2 XLPE 단열 알루미늄 장갑 3X300mm 3X150mm 불 retardant 전력 케이블 공장

IEC 60502-2 XLPE 단열 알루미늄 장갑 3X300mm 3X150mm 불 retardant 전력 케이블

IEC 60502-2 XLPE Insulated Aluminium Armoured 3X300mm 3X150mm Flame Retardant Power Cable Applications The cables arewidely used in places such as wind farms and solar power stations to meet the power transmission needs of these places ‌ Main Technical Properties 1. DC resistance of conductor at 20°C : not exceed ing 0.1 Ω/km; 2. 4h Power Frequency Voltage Test (4U₀) : No breakdown occurred; 3. 50Hz AC Withstand Voltage Test: 65 kV for 30 min ; No breakdown occurred; 4.

품질 6 8 10 가이브 AWG 크기 알루미늄 선도자 전력 케이블 AA8000 XLPE 단열 XHHW XHHW-2 공장

6 8 10 가이브 AWG 크기 알루미늄 선도자 전력 케이블 AA8000 XLPE 단열 XHHW XHHW-2

6 8 10 Gauge AWG Size Aluminum Conductor Cable AA8000 XLPE Insulation XHHW XHHW-2 Application XHHW-2 is primarily used in house construction, conduit, or recognized raceways for services, feeders, and branch circuit wiring in wet or dry locations, at temperatures not to exceed 90°C. Voltage rating is 600V. This product is designed to be installed without the application of pulling lubricant. . Construction Conductor: Aluminum Alloy Insulation: 120℃ XLPE/XLPO Jacket: XLPE, PVC

품질 38/66kV(72.5kV) 고압 케이블 구리 도체 XLPE 절연체 납 피복 전력 케이블 공장

38/66kV(72.5kV) 고압 케이블 구리 도체 XLPE 절연체 납 피복 전력 케이블

38/66kV(72.5kV) High Voltage Cable Copper Conductor XLPE Insulation Lead Sheath Power Cable APPLICATION The cable is suitable for use in high voltage transmission networks, in systems of rated voltages from 60 kV grade up to and including 69 kV grade. CONSTRUCTION Conductor: Stranded circular or segmental (Milliken) compacted copper conductor Conductor shield: Semi-conductive shield Insulation: Cross-Linked Polyethylene(XLPE) Insulation shield: Semi-conductive shield Metal

품질 XLPE 단열 태양 케이블 전기 PV 태양 전지 패널 와이어 1.5MM 2.5MM PV1-F 공장

XLPE 단열 태양 케이블 전기 PV 태양 전지 패널 와이어 1.5MM 2.5MM PV1-F

XLPE Insulated Solar Cable Electric PV Wire 1.5MM 2.5MM PV1-F Application Solar cables are the designated cable used for rooftop PV installations. They are suitable for free hanging, movable, fixed installation and buried in ground in constructional covered systems indoor, outdoor or in hazard explosion areas, in industry and agriculture. Cable performance Properties such as moisture and heat resistance, high and low temperature resistance, acid and alkali resistance,ozone

품질 3.6/6kV 26/35kV 중전압 케이블 XLPE 단열 금속 테이프 장갑 전력 케이블 공장

3.6/6kV 26/35kV 중전압 케이블 XLPE 단열 금속 테이프 장갑 전력 케이블

3.6/6kV~26/35kV Medium Voltage Cable XLPE Insulation PVC Sheath Metal Tape Armouring Power Cable Application Suitable for urban underground power grids, power station outgoing lines, internal power supply lines of industrial and mining enterprises, etc. CONSTRUCTION Conductor: Round compacted conductors Conductor Shield: Semi conductive shielding material (below 500mm Semi conductive tape+semi conductive shielding material (500 mm 2 and above) Insulation: Polyvinyl chloride

품질 Black Copper Conductor Low Voltage Cable XLPE Insulated PVC Sheathed Custom 로고 공장

Black Copper Conductor Low Voltage Cable XLPE Insulated PVC Sheathed Custom 로고

YJV Copper Conductor Low Voltage Cable XLPE Insulated PVC Sheathed Application These cables are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and outdoors, in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage. Construction 1. Conductor: Copper/Aluminum/Aluminum Alloy 2. Insulation: Cross-linked polyethylene XLPE 3

품질 ABC 에어리얼 펀들드 케이블 2 코어 저전압 XLPE 단열 검은색 공장

ABC 에어리얼 펀들드 케이블 2 코어 저전압 XLPE 단열 검은색

ABC Aerial Bundled Cable 2 Cores Low Voltage XLPE Insulation Applications Aerial Bundled Cable (ABC) is widely used in overhead low-voltage power distribution (typically up to 1kV). Its key applications include: Rural & urban power lines – Replaces bare conductors for improved safety and reliability. Storm-prone areas – Resists wind, rain, and environmental damage better than traditional wiring. Crowded or narrow spaces – Compact bundled design minimizes installation space.

품질 YJLHV62 YJLHV22-18/30kV 류미늄 합금 선도자 XLPE 단열 PVC 껍질 금속 테이프 장갑 전력 케이블 공장

YJLHV62 YJLHV22-18/30kV 류미늄 합금 선도자 XLPE 단열 PVC 껍질 금속 테이프 장갑 전력 케이블

YJLHV62 YJLHV22-18/30kV luminium Alloy Conductor XLPE Insulation PVC Sheath Metal Tape Armouring Power Cable Application The AA-8000 series aluminum alloy cables (e.g., AA-8030, AA-8176) are widely used in electrical systems due to their lightweight, cost-efficiency, and superior mechanical/electrical performance compared to pure aluminum. 1. Power Distribution Building Wiring: Branch circuits, feeders, and service entrance cables (NEC Article 310 compliant). Utility Grids:

이전
페이지 7 의 33
다음