logo
발견 146 제품 "

shielded power cable

"
품질 사용자 지정 로고 ABC 에어리얼 펀들드 오버헤드 케이블 PE 단열 3단계 전기 케이블 공장

사용자 지정 로고 ABC 에어리얼 펀들드 오버헤드 케이블 PE 단열 3단계 전기 케이블

ABC Aerial Bundled Overhead Cable PE Insulation 3 Phase Electrical Cable Applicatiom ‌ Copper-shielded ABC (Aerial Bundled Cables) ‌ are primarily used in ‌ overhead power distribution systems ‌ where reliability, electromagnetic interference (EMI) resistance, and durability are critical Construction Characteristics Voltage Rating: 600V Insulation Material: XLPE for enhanced durability and resistance to heat and weather Conductor Material: Aluminum Structure: Overhead twisted

품질 불 retardant 저연소 제로 할로겐 케이블 0.6KV 1kV XLPE 단열 YJY23 공장

불 retardant 저연소 제로 할로겐 케이블 0.6KV 1kV XLPE 단열 YJY23

Flame Retardant Low Smoke Zero Halogen Cable 0.6/1kV XLPE Insulated YJY23 Application ‌Industrial Factory ‌ Power Distribution Systems ‌ ‌High-Risk Buildings ‌Transportation Infrastructure ‌ ‌Hazardous Environments ‌ ‌Emergency Systems Construction Conductor :Class 2 stranded copper conductor Insulation :XLPE (Cross-Linked Polyethylene) Bedding :LSZH (Low Smoke Zero Halogen) Armour :SWA (Steel Wire Armour) Sheath :LSZH (Low Smoke Zero Halogen) Advantage Composite high

품질 IEC 60502 N2XH 저연소 제로 할로겐 LSZH 케이블 XLPE 단열 0.6KV 1kV 공장

IEC 60502 N2XH 저연소 제로 할로겐 LSZH 케이블 XLPE 단열 0.6KV 1kV

IEC 60502 N2XH Low Smoke Zero Halogen Cable XLPE Insulated 0.6/1kV Application Low smoke zero halogen cables are becoming more popular in military applications, aircraft, railway and maritime. This is because in these areas it is often difficult to ventilate in the event of a fire.. Besides, Low smoke halogen free material is also widely used in high pressure underground tunnels or track marking lines in railway system. when using them, reduces the possibility of harmful

품질 주석 도금 연동 연선 전선 2X12 AWG 2심 케이블 공장

주석 도금 연동 연선 전선 2X12 AWG 2심 케이블

Tinned Copper Flexible Stranded Electrical Wire 2X12 AWG 2 Core Cable APPLICATION ‌Industrial equipment‌ requiring high flexibility and durability, such as robotic arms and automated machinery. ‌Power distribution systems‌ where corrosion resistance is critical, especially in marine or humid environments‌ ‌Renewable energy installations‌ (e.g., solar panel arrays) due to its excellent conductivity and tinned oxidation resistance. CONSTRUCTION AND SEPCIFICATION Conductor

품질 단일 코어 저전압 저연소 제로 할로겐 케이블 LSZH TUV 인증 공장

단일 코어 저전압 저연소 제로 할로겐 케이블 LSZH TUV 인증

Single Core Low Voltage Low Smoke Zero Halogen Cable LSZH TUV Certificated Application The Cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit

품질 고온 내성 저연소 제로 할로겐 LSZH 케이블 구리 선도 스크린 공장

고온 내성 저연소 제로 할로겐 LSZH 케이블 구리 선도 스크린

High Temperature Resistant Low Smoke Zero Halogen Cable Copper Conductor Screen Application The Cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial,aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short

품질 구리 와이어 스크린 에어리언 펀들드 케이블 ABC 3 코어 AL/XLPE/HPDE MV 19Kv 33kV 공장

구리 와이어 스크린 에어리언 펀들드 케이블 ABC 3 코어 AL/XLPE/HPDE MV 19Kv 33kV

Copper wire screen ABC Aerial Bundled Cable 3 Core AL/XLPE/HPDE MV 19/33kV Applicatiom Copper-shielded ABC (Aerial Bundled Cables) ‌ are primarily used in ‌ overhead power distribution systems ‌ where reliability, electromagnetic interference (EMI) resistance, and durability are critical. Construction Phase Conductor: Class 2 Circular compacted stranded aluminum Conductor Screen: Extruded semi-conductive layer Insulation: XLPE (Cross-linked polyethylene) Insulation Screen:

품질 100% 절연 MV 케이블 1X630mm2 구리 도체 XLPE 절연 25kV 공장

100% 절연 MV 케이블 1X630mm2 구리 도체 XLPE 절연 25kV

100% Insulated MV Cable 1X630mm2 Copper Conductor XLPE Insulated 25kV Applications The cable is used to transmit large amounts of electrical power at 25 kV from substations to industrial or infrastructure loads. Construction Conductor: Compacted conductors Conductor Shield: Semi conductive tape+semi conductive shielding material Insulation: XLPE Insulation Shield: Peelable semiconducting shielding material Metal Shield Layer: Copper Tape Filler: Polypropylene (PP) m esh f

품질 NYSY KVVP2 제어 케이블 구리/PVC/ 구리 테이프 보호막/PVC 0.6/1kV 공장

NYSY KVVP2 제어 케이블 구리/PVC/ 구리 테이프 보호막/PVC 0.6/1kV

NYSY – KVVP2 Control Cable | Copper/PVC/Copper Tape Shield/PVC | 0.6/1kV Product Overview The NYSY – KVVP2 control cable is a high-performance, screened control cable designed for fixed installation in industrial and commercial environments. With a rated voltage of 0.6/1kV, this cable is specifically engineered for use in control circuits, monitoring systems, and protection circuits, ensuring reliable signal transmission and power delivery where electromagnetic interference