logo
발견 387 제품 "

pvc power cable

"
품질 Overhead Insulated ABC Cable NFC 33-209 0.6/1kV for Power Distribution 공장

Overhead Insulated ABC Cable NFC 33-209 0.6/1kV for Power Distribution

Overhead Insulated ABC Cable NFC 33-209 0.6/1kV for Power Distribution APPLICATION Overhead Power Distribution‌ Rural Electrification & Remote Areas‌ Industrial & Commercial Installations‌ Service Connections‌ Renewable Energy Projects‌ CONSTRUCTION Phase conductors: AAC Insulation: XLPE, UV-resistant. Neutral-supported: AAAC Street lighting conductor: AAC Core identification: Ribs or numbers or colors stripe. SPECIFICATION Number of Cores x Nominal Cross Section Approx.

품질 자가 지지 절연 ABC 케이블 SIP 전선 (농촌 및 외딴 지역 전력 공급용) SIP-4, SIPn-4, SIP-5, SIP-5ng, AsXS, AsXSn 공장

자가 지지 절연 ABC 케이블 SIP 전선 (농촌 및 외딴 지역 전력 공급용) SIP-4, SIPn-4, SIP-5, SIP-5ng, AsXS, AsXSn

Self Supporting Insulated ABC Cable SIP Wire for Rural & Remote Area Electrification SIP-4, SIPn-4, SIP-5, SIP-5ng, AsXS, AsXSn This specialized cable is designed for high-performance power distribution in demanding environments, combining durability, safety, and branding customization. Application This cable is primarily used for low and medium voltage overhead power distribution, especially in areas where traditional pole-and-wire installation is impractical or costly. Its

품질 KCMIL 400 500 전력 배포용 알루미늄 합금 케이블 AA8000 시리즈 공장

KCMIL 400 500 전력 배포용 알루미늄 합금 케이블 AA8000 시리즈

KCMIL 400 500 Aluminium Conductor Cable AA8000 series Aluminum Alloy conductor Application Aluminum alloy cables (e.g., AA-8000 series per ASTM B800) are widely used in power distribution due to their lightweight, cost-effectiveness, and corrosion resistance. Key applications include: 1. Power Transmission & Distribution Building Wiring: Replace copper in residential/commercial circuits (NEC & IEC compliant). Utility Grids: Overhead lines and underground feeders (AA-1350/AA

품질 강철 테이프 STA 저연소 하로겐 자유 케이블 2 클래스 전도기 N2X2Y 방화 retardant 공장

강철 테이프 STA 저연소 하로겐 자유 케이블 2 클래스 전도기 N2X2Y 방화 retardant

Steel Tape STA Low Smoke Zero Halogen Cable Class 2 conductor N2X2Y Application Flame-retardant low-smoke zero-halogen (LSZH/LSOH) cables are widely applied in various critical scenarios due to their enhanced safety and environmental features: ‌Transportation Systems:Deployed in metro systems, light rail transit, and aviation facilities to ensure safe power transmission while minimizing toxic emissions during fire incidents ‌Public Infrastructure: Used in hospitals, schools,

품질 저전압 에어리얼 펀들드 케이블 오버헤드 2x25mm2 스트랜드 된 ABC 알루미늄 케이블 공장

저전압 에어리얼 펀들드 케이블 오버헤드 2x25mm2 스트랜드 된 ABC 알루미늄 케이블

2*25 LOW VOLTAGE ABC Aerial Bundled Cable Overhead 2*25 MM² Stranded Aluminium Cable Application: The ABC 2*25mm² cable (Aerial Bundled Cable) is designed for reliable and efficient low and medium voltage power distribution in overhead electrical systems. This cable is commonly used in urban, rural, and industrial environments for electrical power transmission and is known for its high safety standards , durability , and performance Construction Conductor : Aluminum

품질 15kV 35kV ACSR 선도자 ABC 에어리얼 펀들드 케이블 중압 오버헤드 케이블 공장

15kV 35kV ACSR 선도자 ABC 에어리얼 펀들드 케이블 중압 오버헤드 케이블

15kV 35kV ACSR Conductor ABC Aerial Bundled Cable Medium Voltage Overhead Cable APPLICATION 1 phase:t o supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 1000 volts or lower at a conductor temperature of 75℃ maximum. 2 phase: t o supply power from the utility ’ s lines to the consumer ’ s weatherhead. For service at 1000 volts or less (phase to phase) at a conductor temperature of 75℃ maximum for polyethylen

품질 Quadruplex Service Drop ABC Aerial Bundled Cables 3×70mm²+50mm² 3×95mm²+50mm² 공장

Quadruplex Service Drop ABC Aerial Bundled Cables 3×70mm²+50mm² 3×95mm²+50mm²

Quadruplex Service Drop ABC Aerial Bundled Cables 3×70mm²+50mm² 3×95mm²+50mm² APPLICATION These cables are primarily used for ‌three-phase power distribution‌ from utility poles to residential/commercial service points, typically connecting pole-mounted transformers to weatherheads. The 3×70mm²+50mm² and 3×95mm²+50mm² configurations are designed for medium-to-high current loads, with the larger 95mm² variant supporting higher power demands. Key Applications:‌ Residential

품질 고성능 MV ABC 케이블 12.7/22kv 3x150+50mm 오버헤드 전력 라인 공장

고성능 MV ABC 케이블 12.7/22kv 3x150+50mm 오버헤드 전력 라인

High Performance MV ABC Cable 12.7/22kv 3x150+50mm for Overhead Power Lines Deatils Phase Conductor : Aluminium Conductor Neutral Conductor : AAC/AAAC/ACSR Insulation : XLPE/PE Rated Voltage : 1-35KV Cores : 1,3 Cores Construction Specification UMBER OF CORES X NOMINAL CROSS SECTION PHASE CONDUCTOR MESSENGER SUSPENSION UNIT CONTINUOUS CURRENT RATING AT 300C AMBIENT TEMP STRANDING NOMINAL SECTIONAL AREA MAXIMUM CONDUCTOR RESISTANCE STRANDING NOMINAL SECTIONAL AREA BREAKING

품질 1.5kV 태양광 PV DC 케이블 기후 저항 H1Z2Z2-K 태양 전지 패널 DC 와이어 공장

1.5kV 태양광 PV DC 케이블 기후 저항 H1Z2Z2-K 태양 전지 패널 DC 와이어

1.5kV DC PV Solar Cable Climate Resistance H1Z2Z2-K Application The cable is designed for connecting photovoltaic system components inside and outside of buildings and equipment with high mechanical requirements and extreme weather conditions.It has the characteristics of Climate resistance, UV resistance,aging resistance,and the service life is over 25years. Construction Conductor: Using multiple tin-plated soft copper wire stranded into insulation Insulation: Irradiation