logo
발견 16 제품 "

fire proof cable

"
품질 1 코어 0.6kv 1kv 방화 케이블 구리 선도자 XLPE 단열 방화선 공장

1 코어 0.6kv 1kv 방화 케이블 구리 선도자 XLPE 단열 방화선

Single Core 0.6/1kv Fire Resistant Cable Copper Conductor XLPE Insulated APPLICATION Standard fire resistant cables for use primarily in fire detection, fire alarm, voice alarm, and emergency lighting circuits. These cables are designed to continue to operate for a period of time in a fire situation. ‘Standard’ fire resistance is recommended for general use. Construction Conductor: Plain annealed copper (class 2, normal stranded or compact stranded) Fire barrier: Mica tape

품질 멀티 코어 XLPE 단열 전력 케이블 큐 선도자 방화 케이블 XLPE 단열 EN 60332 공장

멀티 코어 XLPE 단열 전력 케이블 큐 선도자 방화 케이블 XLPE 단열 EN 60332

Multi Core XLPE Insulated Power Cable Cu Conductor Fire Proof Cable with XLPE Insulation EN 60332 APPLICATION ‌Industrial Facilities ‌ Widely used in petrochemical plants, steel mills, and power stations due to its high-temperature resistance (up to 90°C continuous operation) and flame-retardant properties (compliance with IEC 60332-3-22 for group flame spread limits)‌ High-Rise Buildings & Underground Installations ‌ Essential for fire safety in vertical shafts, cable

품질 테르미트 보호 고전압 케이블 케이블 110kV 2XS(FL) 2Y, A2XS(FL) 2Y 공장

테르미트 보호 고전압 케이블 케이블 110kV 2XS(FL) 2Y, A2XS(FL) 2Y

‌Termite-proof‌ High Voltage Cable Cable 110kV 2XS(FL)2Y, A2XS(FL)2Y APPLICATION Urban Grids & Industrial Plants ‌: Used for ‌power transmission and distribution ‌ in cities, factories, and ports due to their ‌high reliability and durability ‌ ‌Outdoor Installations ‌: Suitable for ‌direct burial or aerial mounting ‌ with ‌UV-resistant PVC jackets ‌ and ‌anti-termite additives ‌ (FL) ‌ ‌Underground Networks ‌: Ideal for ‌tunnel or duct systems ‌ with ‌longitudinal water

품질 LV PVC 방화성 공기 연결 케이블 ABC 전력 전송용 오버헤드 전기 케이블 공장

LV PVC 방화성 공기 연결 케이블 ABC 전력 전송용 오버헤드 전기 케이블

Low Voltage PVC Fire Proof Aerial Bundled Cable ABC Overhead Electrical Lines for Power Transmission Applicatiom Low voltage aerial cable is designed to supply 600/1000-volt aerial service for temporary service at construction sites, as a service drop (power pole to service entrance), as a secondary cable (pole to pole) or street lighting. This over-head cable provides reinforced insulation acc. Characteristics Voltage rating: 1kV Test voltage: 4kV, 5min no breakdown.

품질 방화성 XLPE 단열 전력 케이블 3 코어 및 지구 케이블 3 + 1 무장 공장

방화성 XLPE 단열 전력 케이블 3 코어 및 지구 케이블 3 + 1 무장

Fire Proof XLPE Insulated Power Cable 3 Core And Earth Cable 3+1 Unarmoured Application XLPE Insulatied Power Cable 3 core with earth cables are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and outdoors, in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage. Construction Conductor: Plain Annealed copper conductor

품질 알루미늄/폴리에스터 테이프 스크린과 함께 PVC 단열 및 PVC 껍질 제어 케이블 공장

알루미늄/폴리에스터 테이프 스크린과 함께 PVC 단열 및 PVC 껍질 제어 케이블

PVC insulated and PVC Sheathed Control Cable with Aluminium/Polyester Tape Screen APPLICATION The cable is mainly used for system connection wire of control,signal, and for p rotection or measuring for rated voltage up to and including 450/750V. CONSTRUCTION Conductor:Plain annealed stranded circular copper conductor IEC 60228 for class 1 or 2.- class 1 for solid conductors - class 2 for stranded conductors.Insulation:PVC(Polyvinyl Chloride)Metallic Screened; Copper Wire

품질 630mm2 고압 케이블 110kV 전기 단심 구리 방수 내성 전력 공장

630mm2 고압 케이블 110kV 전기 단심 구리 방수 내성 전력

630mm2 High Voltage Cable 110kV Electric Single Core Copper Water Proof Resistant Power APPLICATION For laying indoors,in tunnel cable trench,well or direct in ground,able to bear external mechanical forces and certain pulling force. CONSTRUCTION High Voltage: Designed for power distribution and construction applications. XLPE Insulation: Provides superior electrical insulation and durability. Copper Conductor: Ensures reliable and efficient power transmission. Wide Range of

품질 철선 장갑 방화 케이블 0.6 1.0kV 두 개의 코어 열 방지 전기 케이블 공장

철선 장갑 방화 케이블 0.6 1.0kV 두 개의 코어 열 방지 전기 케이블

Steel Wire Armoured Fire Resistant Cable 0.6/1.0kV Two Core Application Fire resistant cables can be used in several critical buildings where safety against fire is mandatory to reduce the risk of death as: Hospitals & Old people’shomes. Schools & Recreational buildings. Museums & Historical places. Undergrounds & Tunnels. Railways & Airports. Shopping Centers & Malls. Theatres & Cinemas. Hotels & Offices. High-rise buildings Construction Conductor: Plain Annealed

품질 산업용 전기 배선 및 안전 준수 애플리케이션에 적합한 불 retardant 저연소 제로 할로겐 케이블 공장

산업용 전기 배선 및 안전 준수 애플리케이션에 적합한 불 retardant 저연소 제로 할로겐 케이블

Product Description: The Low Smoke Zero Halogen Cable is an advanced wiring solution designed to enhance safety and performance in various electrical and electronic applications. This cable is engineered with materials that produce minimal smoke and no halogen gases when exposed to fire or high temperatures, making it an ideal choice for environments where fire safety is a critical concern. The Zero Halogen Low Smoke Wire offers superior resistance to fire hazards, significan

이전 다음
이전
페이지 1 의 2
다음