logo
見つかりました 129 のための製品 "

lszh cable

"
品質 Cu XLPE PVC SWA PVC 3コア装甲ケーブル XLPE 隔離電線 工場

Cu XLPE PVC SWA PVC 3コア装甲ケーブル XLPE 隔離電線

Cu/XLPE/PVC/SWA/PVC Armoured Electrical Cable XLPE Insulated Cable 3 Core Application Armored cables designed for permanent installations, suitable for both indoor and outdoor use, whether installed in air or underground.They can be mounted on walls, placed in cable ducts, or laid on cable trays.These cables are not intended for installation in wet or submerged conditions. Characteristics Size: 3 core 1.5mm-35mm Conductor: Class 2 stranded plain copper conductor to BS EN

品質 地下電源配給用の3コアとLSZHの低電圧ケーブル 工場

地下電源配給用の3コアとLSZHの低電圧ケーブル

Fire Rated Low Voltage Wire N2XY with 3 Core 1.5-400mm² Underground Power Cable Product Overview Fire Rated Low Voltage Wire with 3 Core 1.5-400mm² is engineered to maintain circuit integrity during fire conditions, ensuring continuous power supply for critical emergency systems. Applications This fire-resistant cable is specifically designed for critical systems including emergency lighting, fire alarms, and evacuation systems. Its three-core configuration (phase, neutral,

品質 1 コア 0.6kv 1kv 防火ケーブル 銅導体 XLPE 断熱式防火線 工場

1 コア 0.6kv 1kv 防火ケーブル 銅導体 XLPE 断熱式防火線

Single Core 0.6/1kv Fire Resistant Cable Copper Conductor XLPE Insulated APPLICATION Standard fire resistant cables for use primarily in fire detection, fire alarm, voice alarm, and emergency lighting circuits. These cables are designed to continue to operate for a period of time in a fire situation. ‘Standard’ fire resistance is recommended for general use. Construction Conductor: Plain annealed copper (class 2, normal stranded or compact stranded) Fire barrier: Mica tape

品質 CE認証 耐火ケーブル 450V 750V 耐火ケーブル 柔軟性ケーブル 工場

CE認証 耐火ケーブル 450V 750V 耐火ケーブル 柔軟性ケーブル

CE Certification Fire Resistant Cable Flexible Cable/Rated voltage 450/750V Application For system connection wire of control, signal, protection or measuring with rated voltage up to and including 450/750KV. Construction Conductor: Plain annealed copper (class 2, normal stranded or compact stranded) Fire barrier: Mica tape Insulation: XLPE Filler, binder and inner covering: PP, PET, LSZH Outer sheath: LSZH Technical parameters Single Core Cross section of conductor(mm²)

品質 単核アルミ導体XLPE断熱AWAケーブル BS 5467規格 工場

単核アルミ導体XLPE断熱AWAケーブル BS 5467規格

Single Core Aluminium Conductor XLPE Insulated AWA Cable to BS 5467 Standard Application Single core aluminium conductor XLPE insulated AWA cable to BS 5467 is widely used for underground and outdoor power distribution, offering excellent mechanical protection and reliable performance in AC systems. Construction The Single Core Aluminium Conductor XLPE Insulated Aluminium Wire Armoured (AWA) Cable to BS 5467 is designed with a robust multilayer construction to ensure reliable

品質 64/110kV 電力ケーブル – 1×800mm² 銅芯架橋ポリエチレン絶縁波付溶接アルミニウムシース高電圧地中ケーブル 工場

64/110kV 電力ケーブル – 1×800mm² 銅芯架橋ポリエチレン絶縁波付溶接アルミニウムシース高電圧地中ケーブル

64/110kV Power Cable – 1×800mm² Copper Core XLPE Insulated Corrugated Welded Aluminium Sheathed High Voltage Underground Cable Product Overview The 64/110kV Power Cable with 1×800mm² copper conductor, XLPE insulation, and corrugated welded aluminium sheath is a premium high voltage underground transmission cable designed for critical power grid infrastructure. Rated at 64/110kV, this single-core cable combines high conductivity copper, solid dielectric insulation, and

品質 難燃性MV中電圧ケーブル 6kV- 26/35kV 鎧装電力ケーブル 工場

難燃性MV中電圧ケーブル 6kV- 26/35kV 鎧装電力ケーブル

Flame-retardant MV Medium Voltage Cable 6kv- 26/35kv Armored Power Cable APPLICATION Suitable for power supply lines with flame retardant requirements, such as urban underground power grids, power station outgoing lines, and internal power lines of industrial and mining enterprises. CONSUCTRUCTION C onductor: Tightly press circular conductor Conductor shield: S emi conductive shielding material (below 500mm ² ) Semi conductive tape+semi conductive shielding material (500mm ²

品質 単体および全体的に遮断された計器ケーブル 多ペアコンピュータケーブル 工場

単体および全体的に遮断された計器ケーブル 多ペアコンピュータケーブル

Individual and Overall Shielded Instrument Cable Multi Pair Computer Cable APPLICATION The cable is suitable for electronic computers and automation instruments with high anti-interference requirements for rated voltage of 500V and below CONSTRUCTION C onductor: The first or second type of copper conductor In s u lation: Low density polyethylene (LLDPE) Fill er (optional): Filling rope Separate shielding: Braided shielding (P) O verall shield: Braided shielding (P) Outer

品質 11kV ATA Aluminum Wire Armored Electrical Cable Single Core AL/XLPE/AWA/CWS/PVC-FR-LS Cable 工場

11kV ATA Aluminum Wire Armored Electrical Cable Single Core AL/XLPE/AWA/CWS/PVC-FR-LS Cable

11kV ATA Aluminum Wire Armored Electrical Cable Single Core AL/XLPE/AWA/CWS/PVC-FR-LS Cable APPLICATION 11kV ATA Aluminum Wire Armored Electrical Cable (Single Core AL/XLPE/AWA/CWS/PVC-FR-LS) is a specialized medium-voltage power cable designed for industrial and urban power distribution systems. Its key applications include: Underground Power Transmission‌. Industrial Facilities‌ Renewable Energy Projects‌ Critical Infrastructure‌ CONSTRUCTION Conductor: Plain annealed

前回
ページ 7 の 15
次へ