| Luogo di origine: | Hebei, Cina |
|---|---|
| Marca: | Aerial Bundled Cable |
| Certificazione: | CCC,ISO,TUV,CE, EAC |
| Numero di modello: | ABC |
| Quantità di ordine minimo: | Negoziabile |
| Prezzo: | Negoziabile |
| Imballaggi particolari: | Rotoli, tamburi in legno, tamburi in acciaio, bobine o personalizzate |
| Tempi di consegna: | 7-30 giorni in base alla quantità diversa |
| Termini di pagamento: | L/C,T/T,Western Union |
| Capacità di alimentazione: | 100 km/settimana |
| Modello n: | Cavo ABC | Materiale dell'anima del filo: | Alluminio |
|---|---|---|---|
| materiale della guaina: | XLPE | Nucleo: | 3+1 |
| Voltaggio: | 0.6/1KV | Applicazione: | Linea sopraelevata |
3+1 Core ABC Cable (Aerial Bundle Cable) for Overhead Power Distribution Systems
Product Overview
3+1 Core ABC Cable is an aerial insulated cable designed for overhead power distribution systems. The "3+1" configuration consists of three phase conductors (for power transmission) and one neutral conductor (usually with a reduced cross-section or support messenger). This design is widely used in rural electrification, urban network expansion, and overhead line replacements where bare conductors are being phased out for safety reasons.
Typical applications
0.6/1kV overhead distribution networks
Rural electrification projects
Temporary construction power supply
Replacement of bare overhead conductors in high-tree-density areas
Technical Specifications
| Parameter | Value |
|---|---|
| Standard | IEC 60502, DIN 48204, or customer-specified (ASTM/BS) |
| Voltage Rating | 0.6/1kV |
| Core Configuration | 3 Phase + 1 Neutral (or 3 Phase + 1 Messenger) |
| Conductor Material | Aluminum (AAAC, AAC, or ACSR as specified) |
| Insulation Material | XLPE (Cross-linked Polyethylene) or PVC |
| Temperature Range | -40°C to +90°C (XLPE) |
| Neutral Option | Standard neutral or with integrated steel messenger for self-supporting installation |
Available cross-sections (mm²):
Phase conductors: 16, 25, 35, 50, 70, 95, 120
Neutral: 16, 25, or as per customer formula
Key Features – Why This Configuration Works
1. Safer than bare conductors
The fully insulated design prevents accidental contact, reduces line faults caused by tree branches or animals, and allows closer pole spacing.
2. Reduced installation time
Aerial bundled cables can be installed with simpler hardware than bare conductors. No need for cross-arms or insulators in many cases – direct pole mounting is possible.
3. Lower power losses
XLPE insulation provides excellent dielectric properties, reducing leakage current and improving transmission efficiency over long distances.
4. Weather-resistant construction
UV-stabilized insulation resists cracking, moisture ingress, and temperature cycling – proven in desert, coastal, and mountainous environments.
Project Case
Project type: Rural electrification, Southeast Asia
Specification: 3+1 core, 70mm² phase / 35mm² neutral, XLPE insulated, 0.6/1kV
Result: 14km line installed in 23 days. No weather-related outages in first 18 months. The utility reports 30% reduction in maintenance calls compared to adjacent bare conductor lines.
We have supplied ABC cable to utilities and contractors in Vietnam, Philippines, Indonesia, Kenya, and Peru. For specific reference documents, please contact us with your project location.
Quality Assurance & Testing
Each production batch is tested according to IEC 60502 requirements, including:
| Test | Method |
|---|---|
| Conductor resistance | DC bridge, 20°C |
| High voltage test | 3.5kV AC for 5 minutes |
| Insulation resistance | 1000V megger, >1000 MΩ·km |
| Hot set test (XLPE) | 200°C, 15 minutes, <175% elongation |
| UV aging | 720 hours accelerated weathering |
Available upon request
Factory test reports (FTR) for each drum
Third-party inspection (SGS, BV, TÜV) at buyer's cost
Sample cable lengths for destructive testing
Request Information
To help you faster, please provide when inquiring:
Required cross-section (phase and neutral mm²)
Insulation type (XLPE or PVC)
Quantity (km or drums)
Destination port
Any specific standard (IEC, BS, ASTM, etc.)
![]()
![]()
![]()
![]()
Rating complessivo
Rappresentazione del rating
Di seguito è riportata la distribuzione di tutte le valutazioniTutte le recensioni