logo
Trovato 124 prodotti per "

shielded power wire

"
Qualità Cavo di alimentazione con conduttore in lega di alluminio isolato in XLPE 3 conduttori NA2XS2Y / NA2XS(F)2Y / NA2X(FL)2Y Fabbrica

Cavo di alimentazione con conduttore in lega di alluminio isolato in XLPE 3 conduttori NA2XS2Y / NA2XS(F)2Y / NA2X(FL)2Y

Aluminium Alloy Conductor XLPE Insulated Power Cable 3 Core NA2XS2Y / NA2XS(F)2Y / NA2X(FL)2Y APPLICATION ‌Industrial & Commercial Power Supply ‌: Widely used in factory power distribution, substations, and large-scale commercial buildings. Direct Burial ‌: The steel tape armor (ST) provides excellent mechanical protection against impacts and crushing forces, making it suitable for direct burial in rocky or hard soil. Bridge & Tunnel Applications ‌: Preferred in bridges and

Qualità MV Medium Voltage XLPE Insulated Power Cable Three Core Copper Tape Shield EN60502 Fabbrica

MV Medium Voltage XLPE Insulated Power Cable Three Core Copper Tape Shield EN60502

MV Medium Voltage XLPE Insulated Power Cable Three Core Copper Tape Shield EN60502 APPLICATION ‌Urban & Industrial Power Networks‌:Used in ‌substations, factories, and commercial buildings‌ for reliable power transmission. Suitable for ‌underground cabling‌ in densely populated areas due to its ‌copper tape shielding‌, which reduces electromagnetic interference (EMI)‌ ‌Renewable Energy Projects‌:Deployed in ‌wind farms and solar power plants‌ for medium-voltage connections

Qualità Cavo di Alimentazione MT Ignifugo CU/XLPE/CTS/CWS/SWA/FR-PVC per Linea Uscente di Centrale Elettrica Fabbrica

Cavo di Alimentazione MT Ignifugo CU/XLPE/CTS/CWS/SWA/FR-PVC per Linea Uscente di Centrale Elettrica

Fire Resistant MV Power Cable CU/XLPE/CTS/CWS/SWA/FR-PVC Cable for Outgoing Line of Power Station Application This product is suitable for power supply lines with flame retardant requirements, such as urban underground power grids, power station outgoing lines, and internal power lines of industrial and mining enterprises. Construction Conductor: Tightly press round conductor Conductor Screen: Semi-conductive shield Insulation:XLPE Insulation shield: Semi-conductive shield

Qualità Reti di distribuzione a 110kV Cavo di alimentazione ad alta tensione CU/XLPE/CWS/STA/PE Fabbrica

Reti di distribuzione a 110kV Cavo di alimentazione ad alta tensione CU/XLPE/CWS/STA/PE

110kV Distribution Networks High Voltage Power Cable CU/XLPE/CWS/STA/PE APPLICATION This cable is designed for ‌high-reliability, high-safety power transmission‌ in complex environments, particularly for fixed installations in demanding conditions. CONSTRUCTION Conductor:Co pper conductor Conductor shield: Semi-conductive shield Insulation: Cross-Linked Polyethylene(XLPE) Insulation shield: Semi-conductive shield Metal shielding layer: Copper Wire Binder tape: Non-woven

Qualità CU XLPE PVC Cavo di alimentazione a bassa tensione Cavo di rame con filo blindato 0,6/1kV Fabbrica

CU XLPE PVC Cavo di alimentazione a bassa tensione Cavo di rame con filo blindato 0,6/1kV

CU/XLPE/PVC Low Voltage Cable Copper Wire Shielded Cable 0.6/1kV Application The cable could be laying indoors, in tunnel, cable trench, or direct in ground, they can bear external mechanical forces, but unable to bear large pulling force. Construction Conductor:Circular, solid, compacted or sector shaped stranded Copper or aluminum Insulation:XLPE Filler: Non-hygroscopic material Screen: Copper Wire Binder tape:: Non-hygroscopic material Sheath PVC Characteristics Test

Qualità Distribuzione dell'energia Industriale Cavo di alimentazione MV 26/35kV AL/XLPE/CTS/STA/PVC YJLV22 NA2XSEBY Fabbrica

Distribuzione dell'energia Industriale Cavo di alimentazione MV 26/35kV AL/XLPE/CTS/STA/PVC YJLV22 NA2XSEBY

Power Distribution Industrial MV Power Cable 26/35kV AL/XLPE/CTS/STA/PVC YJLV22 NA2XSEBY Application 1. Underground and outdoor power networks2. Cable duct installations3. Industrial substations4. Commercial power distribution5. Renewable energy systems6. Mining and heavy industry7. Telecommunications infrastructure8. Smart grid deployments Construction Conductor: Class 2 Aluminium conductor Conductor: Semi-conductive shield Insulation: Cross-Linked Polyethylene(XLPE)

Qualità Cable elettrico blindato in alluminio da 70 mm a 400 mm quadrati Fabbrica

Cable elettrico blindato in alluminio da 70 mm a 400 mm quadrati

Underground Medium Voltage 11kv 15kv 22kv 70mm-400 Sqmm Aluminium Armoured Power Cable Application The cables are designed for distribution of electrical power with nominal voltage Uo/U ranging from 1KV to 35KV and frequency 50Hz, as in power supply stations, indoors and in cable ducts, outdoors, underground. Construction Conductor: Class 2 Aluminium conductor Conductor: Semi-conductive shield Insulation: Cross-Linked Polyethylene(XLPE) Insulation shield: Semi-conductive

Qualità Cable strumentale a scudo torto a più coppie 2/4/5/12 coppia 20awg 22awg 24awg Fabbrica

Cable strumentale a scudo torto a più coppie 2/4/5/12 coppia 20awg 22awg 24awg

Multi Pair Twisted Shielded Instrument Cable 2/4/5/12 Pair 20awg 22awg 24awg APPLICATION Multi pair twisted cables are fundamental in modern communication and data transmission systems, offering reliable performance across various industries. Their structured design with individually twisted wire pairs minimizes electromagnetic interference (EMI) and crosstalk, making them indispensable in: Telecommunications Networking Infrastructure Industrial Automation Audio-Visual

Qualità Cavo di alimentazione in alluminio di lunghezza personalizzata con tensione 6/10kV e conduttore in lega di alluminio della serie 8000 Fabbrica

Cavo di alimentazione in alluminio di lunghezza personalizzata con tensione 6/10kV e conduttore in lega di alluminio della serie 8000

Custom Length Aluminium Power Cable AL/XLPE/STA SWA/PVC NA2XRY NA2X2Y Applications Industrial Power Distribution: Suitable for factories, manufacturing plants, and heavy machinery Infrastructure Projects: Used in construction, tunnels, bridges, and underground installations Renewable Energy: Deployed in solar and wind farms for power transmission Urban Networks: Applied in urban power grids, street lighting, and public facilities Cable Construction Conductor: Round compacted