| Tempat asal: | Hebei, Tiongkok |
|---|---|
| Nama merek: | Bare conductor |
| Sertifikasi: | CCC,ISO,TUV,CE |
| Nomor model: | AAC |
| Kuantitas min Order: | Bisa dinegosiasikan |
| Harga: | dapat dinegosiasikan |
| Kemasan rincian: | Drum Kayu / Drum Baja |
| Waktu pengiriman: | 7-30 hari berdasarkan Qty yang berbeda |
| Syarat-syarat pembayaran: | L/C,T/T |
| Menyediakan kemampuan: | 100 km/minggu |
| Aplikasi: | Jalur distribusi overhead | Nilai Tegangan: | 12 kV |
|---|---|---|---|
| Gelar Instalasi: | -20 ℃ -90 ℃ | Utusan netral: | AAC, AAAC atau ACSR |
| Daerah bagian: | 10, 40, 100, 300.400, 500, 630.800. 1200, 1500…… | Standar: | IEC 61089 DIN 48201-5 ASTM B231 EN 50182 |
| Menyoroti: | AAC konduktor aluminium telanjang 630mm2,jalur udara dengan konduktor telanjang ASTM,Konduktor aluminium kosong standar IEC |
||
Konduktor Aluminium Telanjang AAC 630mm2 untuk Saluran Udara 12kV, Standar ASTM & IEC
Konduktor Udara AAC (All Aluminium Conductor) 630mm² 12kV adalah konduktor udara telanjang berkapasitas tinggi yang dirancang untuk jaringan distribusi daya tegangan menengah. Konduktor ini banyak digunakan dalam sistem 11kV–12kV di mana kapasitas pembawa arus tinggi, kehilangan daya rendah, dan transmisi jarak jauh yang andal diperlukan.Terbuat dari untaian aluminium dengan kemurnian tinggi, konduktor ini menawarkan konduktivitas listrik yang sangat baik, struktur yang ringan, dan kinerja yang hemat biaya dibandingkan dengan alternatif tembaga.Fitur Utama
Konduktor aluminium konduktivitas tinggi untuk transmisi daya yang efisien
Jaringan pasokan daya industri (pabrik baja, pabrik semen, pabrik petrokimia)
Kami memproduksi konduktor AAC sesuai dengan standar internasional, memastikan kualitas yang konsisten, konduktivitas tinggi, dan kinerja mekanis yang sangat baik. Produk kami banyak diekspor dan dipercaya dalam proyek infrastruktur daya di seluruh dunia.
Item
| AAC 400mm² | AAC 630mm² | Kapasitas Arus | Sedang |
|---|---|---|---|
| Tinggi | Panduan Pemilihan | Kehilangan Saluran | Lebih Tinggi |
| Sedang | Terendah | Panduan Pemilihan | Distribusi lokal |
| Perkotaan + industri | Industri berat + jarak jauh | Biaya | Rendah |
| Sedang | Lebih Tinggi (tetapi lebih efisien) | Panduan Pemilihan | Lebih Rendah |
| Sedang | Persyaratan kekuatan tinggi | Panduan Pemilihan | Kota kecil, industri ringan |
| Jaringan perkotaan, pabrik | Pabrik baja, pelabuhan, gardu induk | Jarak Transmisi | Pendek |
| Sedang | Jarak jauh | Panduan Pemilihan | Pilih |
SpesifikasiLuas penampang nominal mm2
|
Jumlah untaian |
Diameter |
Perkiraan berat kabel |
Beban Putus Nominal |
Resistansi DC Maksimum pada 20°C |
Untaian tunggal |
Konduktor |
|
|
mm |
mm |
||||||
|
kN |
kN |
Ω/km |
10 |
10 |
|||
|
1.35 |
1.35 |
10.2 |
27.4 |
1.95 |
2.8633 |
16 |
16 |
|
1.71 |
1.71 |
10.2 |
43.8 |
3.04 |
1.7896 |
25 |
25 |
|
2.13 |
2.13 |
10.2 |
68.4 |
4.5 |
1.1453 |
40 |
40 |
|
315 |
315 |
10.2 |
109.4 |
6.8 |
0.7158 |
63 |
63 |
|
3.39 |
3.39 |
10.2 |
172.3 |
10.39 |
0.4545 |
100 |
100 |
|
2.59 |
2.59 |
20.5 |
274.8 |
17 |
0.2877 |
125 |
125 |
|
2.89 |
2.89 |
20.5 |
343.6 |
21.25 |
0.2302 |
160 |
160 |
|
1120 |
1120 |
20.5 |
439.8 |
26.4 |
0.1798 |
200 |
200 |
|
1400 |
1400 |
20.5 |
549.7 |
32 |
0.1439 |
250 |
250 |
|
4.09 |
4.09 |
20.5 |
2207.4 |
40 |
0.1151 |
315 |
315 |
|
3.29 |
3.29 |
30.7 |
867.9 |
51.97 |
0.0916 |
400 |
400 |
|
3.71 |
3.71 |
30.7 |
1102 |
64 |
0.0721 |
450 |
450 |
|
3.94 |
3.94 |
30.7 |
1239.8 |
72 |
0.0641 |
600 |
600 |
|
4.15 |
4.15 |
30.7 |
1377.6 |
80 |
0.0577 |
560 |
560 |
|
4.39 |
4.39 |
30.7 |
1542.9 |
89.6 |
0.0515 |
630 |
630 |
|
3.63 |
3.63 |
41.1 |
1738.3 |
100.8 |
0.0458 |
710 |
710 |
|
3.85 |
3.85 |
41.1 |
1959.1 |
113.6 |
0.0407 |
800 |
800 |
|
4.09 |
4.09 |
41.1 |
2207.4 |
128 |
0.0361 |
900 |
900 |
|
4.33 |
4.33 |
41.1 |
2483.3 |
144 |
0.0321 |
1000 |
1000 |
|
4.57 |
4.57 |
41.1 |
2759.2 |
160 |
0.0289 |
1120 |
1120 |
|
3.96 |
3.96 |
50.4 |
3093.5 |
179.2 |
0.0258 |
1250 |
1250 |
|
4.18 |
4.18 |
50.4 |
3452.6 |
200 |
0.0231 |
1400 |
1400 |
|
4.43 |
4.43 |
50.4 |
3866.9 |
224 |
0.0207 |
1500 |
1500 |
|
4.58 |
4.58 |
50.4 |
4143.1 |
240 |
0.0193 |
Pabrik |
Proyek |
![]()
![]()
![]()
Konduktor AAC 630mm² menawarkan kapasitas pembawa arus yang lebih tinggi dan resistansi listrik yang lebih rendah dibandingkan dengan ukuran yang lebih kecil seperti 300mm² atau 400mm². Konduktor ini ideal untuk transmisi beban berat dan jarak jauh di mana pengurangan kehilangan daya diperlukan.
Ya, konduktor aluminium memiliki ketahanan korosi alami yang baik. Namun, di lingkungan yang sangat korosif seperti area pesisir atau kimia industri, perlindungan tambahan atau pemeliharaan yang tepat mungkin direkomendasikan untuk masa pakai yang lebih lama.
AAC terbuat dari untaian aluminium murni dan menawarkan konduktivitas yang sangat baik. AAAC menggunakan paduan aluminium untuk kekuatan mekanis yang lebih tinggi, sementara ACSR menggabungkan aluminium dengan inti baja untuk kekuatan tarik ekstra pada saluran udara bentang panjang.
Konduktor AAC biasanya diproduksi sesuai dengan standar IEC 61089, ASTM B231, atau BS tergantung pada persyaratan proyek. Standar-standar ini mendefinisikan sifat listrik, mekanis, dan dimensi konduktor.
Peringkat Keseluruhan
Cuplikan Peringkat
Berikut adalah distribusi dari semua peringkatSemua Ulasan