Detail produk:
Tempat asal: Hebei, Cina
Nama merek: Zhongdong
Sertifikasi: CCC,ISO,TUV,CE
Nomor model: ABC
Syarat-syarat pembayaran & pengiriman:
Kuantitas min Order: Bisa dinegosiasikan
Harga: dapat dinegosiasikan
Kemasan rincian: Drum Kayu / Drum Baja
Waktu pengiriman: 7-30 hari berdasarkan qty yang berbeda
Syarat-syarat pembayaran: , L/c, t/t
Menyediakan kemampuan: 100 km/minggu

19/33kV Screened Medium Voltage MV ABC Kabel ke IEC 60502 3X150mm + 1X50mm

Deskripsi
Aplikasi: Jalur distribusi overhead Core No.: 1,2,3,4 lebih multicore
Tegangan Dinilai: 15/35KV Gelar Instalasi: -20 ℃ -90 ℃
Utusan netral: AAC, AAAC atau ACSR Isolasi: PE/PVC
Menyoroti:

Kabel 19/33kV MV ABC

,

kabel tegangan menengah yang disaring

,

Kabel MV yang sesuai dengan IEC 60502

Kabel MV ABC Berpelindung 19/33kV ke IEC 60502 3X150mm + 1X50mm


APLIKASI

  • Cocok untuk instalasi di dalam/luar ruangan, parit kabel, terowongan, dan penempatan bawah tanah atau bawah air‌.
  • Digunakan dalam jaringan distribusi daya, gardu induk, dan pabrik industri yang membutuhkan tingkat tegangan 19/33kV‌.
  • Ideal untuk lingkungan bebas saluran magnetik (kabel inti tunggal dibatasi dalam saluran magnetik)‌


KONSTRUKSI 

  • Konduktor:Aluminium H68 Terpilin Kompak Melingkar (Kelas 2) 
  • Pelindung Konduktor:Lapisan Semi-konduktif Ekstrusi 
  • Isolasi:XLPE 
  • Pelindung Isolasin:Lapisan Semi-konduktif Ekstrusi 
  • Pelindung Logam:Pelindung kawat tembaga atau pelindung pita tembaga 
  • Selubung Luar:HDPE 
  • Konduktor Pendukung:Kawat baja galvanis


19/33kV Screened Medium Voltage MV ABC Kabel ke IEC 60502 3X150mm + 1X50mm 019/33kV Screened Medium Voltage MV ABC Kabel ke IEC 60502 3X150mm + 1X50mm 1





KARAKTERISTIKPeringkat tegangan: 

 

  • 19/33kVOperasi normal 90°C.
  • Kondisi kelebihan beban darurat 130°C.
  • Kondisi hubungan pendek 250°C.
  • SPESIFIKASI


NO. Inti X


Penampang Nominal
Konduktor Fasa

Unit Suspensi Messenger

Peringkat Arus Kontinu

pada Suhu Ambien 300C
Terpilin

Luas Penampang Nominal

Beban Putus

Luas Penampang Nominal

Beban Putus

No.×mm²

No.×mm

mm2

KN

mm2

KN

A

3X50 + 1X50

19/1.78

50

62

50

62

315

3X150 + 1X50

37/2.25

150

7/3.15

50

62

315

3X185+ 1X70

37/2.52

185

7/3.57

70

7/3.15

355

3X70+1X50

19/2.14

70

7/3.15

50

62

370

3X150 +1X50

37/2.25

150

7/3.15

50

62

370

TENTANG KAMI


MENGAPA MEMILIH KAMI


19/33kV Screened Medium Voltage MV ABC Kabel ke IEC 60502 3X150mm + 1X50mm 2


PROYEK

19/33kV Screened Medium Voltage MV ABC Kabel ke IEC 60502 3X150mm + 1X50mm 3


PAKET

19/33kV Screened Medium Voltage MV ABC Kabel ke IEC 60502 3X150mm + 1X50mm 4


MITRA

19/33kV Screened Medium Voltage MV ABC Kabel ke IEC 60502 3X150mm + 1X50mm 5


FAQ

19/33kV Screened Medium Voltage MV ABC Kabel ke IEC 60502 3X150mm + 1X50mm 619/33kV Screened Medium Voltage MV ABC Kabel ke IEC 60502 3X150mm + 1X50mm 7


Apa kepatuhan standar kabel ini?‌

Kabel mematuhi ‌IEC 60502-2‌ untuk kabel daya berinsulasi XLPE tegangan menengah, memastikan keandalan global

Bahan apa saja yang digunakan dalam konstruksi kabel?‌
Konduktor‌: Aluminium (terpilin Kelas 2); ‌Isolasi‌: XLPE; ‌Pelindung‌: Lapisan semikonduktif; ‌Selubung‌: PVC atau HDPE untuk ketahanan luar ruangan

Apa saja aplikasi umumnya?‌
Cocok untuk instalasi ‌overhead, bawah tanah, dan industri‌ dalam jaringan distribusi daya, gardu induk, dan proyek energi terbarukan

Berapa peringkat tegangan dan konfigurasinya?‌
Dinilai untuk ‌19/33kV‌, dengan konfigurasi inti 3+1 (konduktor fasa 3x150mm² + konduktor netral 1x50mm²)

Apakah kabel tersebut menyertakan perlindungan lapis baja?‌
Tersedia dengan ‌lapis baja kawat baja (SWA)‌ atau ‌pita baja galvanis‌ untuk perlindungan mekanis di lingkungan yang keras.

Sertifikasi apa saja yang dipenuhi kabel tersebut?‌
Disertifikasi sesuai standar ‌ISO, CCC, CE, dan VDE‌, memastikan penerimaan pasar internasional.

Berapa jumlah pesanan minimum (MOQ)?‌
Persyaratan MOQ yang fleksibel

Bisakah kabel tersebut disesuaikan?‌
Ya, opsi termasuk ‌peringkat tegangan (11-35kV), bahan konduktor (aluminium/tembaga), dan warna selubung‌.

Apa saja batas suhu dan lingkungan?‌
Suhu pengoperasian‌: -40°C hingga +90°C; Selubung tahan UV untuk penggunaan di luar ruangan.

Di mana saya dapat meminta sampel atau dukungan teknis?‌
Hubungi KAMI untuk sampel, lembar data, dan saran khusus proyek





Rincian kontak
Zhongdong Cable Co., Ltd.

Kontak Person: Mr. Bai

Tel: +8619829885532

Mengirimkan permintaan Anda secara langsung kepada kami (0 / 3000)