logo
Ditemukan 347 produk untuk "

xlpe power cable

"
Kualitas Kabel Cabang Prefab Customized XLPE PVC Kabel Daya Terisolasi 3,5KV Pabrik

Kabel Cabang Prefab Customized XLPE PVC Kabel Daya Terisolasi 3,5KV

3.5KV Customized Prefabricated Branch Cable XLPE/PVC Insulted Pre-branch Cable Application The cable is to connect the required number of branch cables at the specified trunk cable position according to the actual needs of users during production. During construction, the cable reel can be set out evenly by hanging with a hook, which is very convenient. Besides, the cable branch joints have been specially treated, and have reliable power supply and certain waterproof

Kualitas Tembaga Konduktor Tegangan Menengah MV Kabel Daya 8.7/15kV XLPE Isolasi Pabrik

Tembaga Konduktor Tegangan Menengah MV Kabel Daya 8.7/15kV XLPE Isolasi

Copper Conductor Medium Voltage Cable 8.7/15kV Cu/XLPE/PVC/SWA Construction Conductor: Circular compacted stranded Copper or aluminium Conductor screen: Extruded semi-conductive compound Insulation: XLPE Insulation screen: Extruded semi-conductive compound Metallic screen: Copper Wire Binder tape: non-hygroscopic material Inner covering(bedding): PVC Metallic armor: Galvanized steel tape Application Medium-voltage cables (typically rated between 1 kV and 35 kV) are extensivel

Kualitas 6 8 10 Gauge AWG Ukuran Aluminium Konduktor Kabel Daya AA8000 XLPE Isolasi XHHW XHHW-2 Pabrik

6 8 10 Gauge AWG Ukuran Aluminium Konduktor Kabel Daya AA8000 XLPE Isolasi XHHW XHHW-2

6 8 10 Gauge AWG Size Aluminum Conductor Cable AA8000 XLPE Insulation XHHW XHHW-2 Application XHHW-2 is primarily used in house construction, conduit, or recognized raceways for services, feeders, and branch circuit wiring in wet or dry locations, at temperatures not to exceed 90°C. Voltage rating is 600V. This product is designed to be installed without the application of pulling lubricant. . Construction Conductor: Aluminum Alloy Insulation: 120℃ XLPE/XLPO Jacket: XLPE, PVC

Kualitas CU XLPE PVC Low Voltage Power Cable Wire Copper Shielded Cable 0,6/1kV Pabrik

CU XLPE PVC Low Voltage Power Cable Wire Copper Shielded Cable 0,6/1kV

CU/XLPE/PVC Low Voltage Cable Copper Wire Shielded Cable 0.6/1kV Application The cable could be laying indoors, in tunnel, cable trench, or direct in ground, they can bear external mechanical forces, but unable to bear large pulling force. Construction Conductor:Circular, solid, compacted or sector shaped stranded Copper or aluminum Insulation:XLPE Filler: Non-hygroscopic material Screen: Copper Wire Binder tape:: Non-hygroscopic material Sheath PVC Characteristics Test

Kualitas Tembaga Konduktor Lead Sheath Kabel Daya Tegangan Tinggi 110kV XLPE Isolasi Pabrik

Tembaga Konduktor Lead Sheath Kabel Daya Tegangan Tinggi 110kV XLPE Isolasi

Copper Conductor Lead Sheath Screen High Voltage Cable XLPE Insulation Application ‌Power station connections: Transmitting electricity from generators to substations or directly integrating into grid systems‌, Suitable for ‌underground installations‌ in complex terrains (e.g., mountainous regions) to ensure stable power delivery‌ ‌Urban power networks: Deployed in densely populated areas where overhead lines are impractical, minimizing spatial occupation and enhancing safety

Kualitas 26/35kV 3 inti tahan api Aluminium konduktor kabel listrik untuk proyek fotovoltaik Pabrik

26/35kV 3 inti tahan api Aluminium konduktor kabel listrik untuk proyek fotovoltaik

26/35kV 3 Core Fire Resistant Aluminium Conductor Power Cable for Photovoltaic Project Overview The 26/35kV 3 Core Fire Resistant Aluminium Conductor Power Cable for Photovoltaic Projects is engineered for medium-voltage power transmission in utility-scale solar farms, renewable energy substations, and photovoltaic distribution systems. Designed for harsh outdoor environments and critical power continuity applications, this cable combines excellent electrical performance,

Kualitas Fotovoltaic Aluminium Alloy Conductor Power Cable Panjang yang Disesuaikan Pabrik

Fotovoltaic Aluminium Alloy Conductor Power Cable Panjang yang Disesuaikan

Photovoltaic Aluminium Conductor Cable Aluminum Alloy 8000 Series Conductor Application Application Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities. May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC Construction Phase conductor: Aluminum alloy conductor 8000

Kualitas Tegangan Rendah Asap Rendah Nol Kabel Daya Halogen LSZH Tahan Api Tidak Lapis Pabrik

Tegangan Rendah Asap Rendah Nol Kabel Daya Halogen LSZH Tahan Api Tidak Lapis

Low Smoke Zero Halogen Low Voltage Cable LSZH Fire Resistant Unarmoured APPLICATION The cables are specialized high-safety cables designed for environments where both fire integrity and human safety are the top priorities, such as fire alarms, airports and railway stations, hospitals and schools and data centers etc. CCONSTRUCTION Conductor :Class 2 stranded copper conductor Insulation :XLPE (Cross-Linked Polyethylene) Bedding :LSZH (Low Smoke Zero Halogen) Sheath :LSZH (Low

Kualitas Kabel Listrik Halogen Beras Beras Beras SWA 0.6/1 KV 3x4mm Pabrik

Kabel Listrik Halogen Beras Beras Beras SWA 0.6/1 KV 3x4mm

Armored Copper Low Smoke Zero Halogen SWA 0.6/1 KV 3*4mm Application Low Smoke Zero Halogen (LSZH) cables are a reliable and high-performance solution for applications demanding superior safety, environmental protection, and compliance with stringent standards. Their low smoke emission, zero halogen properties, and flame-retardant characteristics make them ideal for public buildings, transportation infrastructure, industrial facilities, high-rise buildings, and data centers,