| उत्पत्ति के प्लेस: | हेबेई, चीन |
|---|---|
| ब्रांड नाम: | 110kV power cable |
| प्रमाणन: | CCC,ISO,TUV,CE, EAC |
| मॉडल संख्या: | 2XS(FL)2Y |
| न्यूनतम आदेश मात्रा: | बातचीत करने के लिए |
| मूल्य: | To be negotiated |
| पैकेजिंग विवरण: | रोल, लकड़ी के ड्रम, स्टील ड्रम, रील या अनुकूलित |
| प्रसव के समय: | विभिन्न मात्रा के आधार पर 7-30 दिन |
| भुगतान शर्तें: | एल/सी, टी/टी, वेस्टर्न यूनियन |
| आपूर्ति की क्षमता: | 100 किमी/सप्ताह |
| शक्ति: | 110kV | कवच प्रकार: | एसडब्ल्यूए बख्तरबंद |
|---|---|---|---|
| धात्विक स्क्रीन: | तांबे का तार | इन्सुलेशन सामग्री: | एक्स एल पी ई |
| जैकेट: | पीवीसी | आवेदन: | ग्रिड ट्रांसमिशन |
Product Overview
Designed for critical 110kV transmission networks, this single-core or three-core copper conductor cable delivers high-capacity power flow from primary substations to heavy load centers. Manufactured under strict compliance with IEC 60840 (Power cables with extruded insulation and their accessories for rated voltages above 30 kV up to 150 kV), this model CU/XLPE/PVC/SWA/PVC combines high thermal endurance with mechanical armor, making it ideal for direct burial, tunnels, or outdoor trays in smart grid projects.
Technical correction note: For 110kV, IEC 60502 is not applicable (max 30kV). Our cable strictly follows IEC 60840 to ensure legal compliance and grid operator acceptance.
Key Specifications at a Glance
|
Parameter |
Value |
|---|---|
|
Rated Voltage (U₀/U) |
64/110 kV |
|
Conductor |
Class 2 Stranded Copper (CU) – High conductivity, corrosion resistant |
|
Insulation |
Cross-linked Polyethylene (XLPE) – IEC 60840 grade |
|
Inner Sheath |
Polyvinyl Chloride (PVC) – bedding layer |
|
Armor |
Steel Wire Armor (SWA) – Galvanized, for mechanical & pulling protection |
|
Outer Sheath |
PVC (ST2 or ST7) – UV & hydrocarbon resistant |
|
Standard |
IEC 60840, IEC 60287 (current rating), IEC 60754 (halogen options available) |
1. Conductor:
Stranded annealed copper (CU) – Class 2 circular or shaped.
Optional: Longitudinal water blocking or copper tape shielding.
2. Conductor Screen (Semiconductive):
Bonded XLPE-based semi-conducting layer to eliminate air voids and homogenize electrical stress.
3. XLPE Insulation (Main Insulation):
Dry-cured, super-clean XLPE with low dissipation factor.
Thickness per IEC 60840 (typically ≥16mm for 110kV).
Rated temperature: 90°C (normal), 250°C (short circuit).
4. Insulation Screen:
Strippable or bonded semi-conducting layer + swelling tape.
5. Metallic Screen (Copper Wire or Tape):
Helically applied copper wires + counter-helical copper tape.
Earth fault capacity designed per system requirements.
6. PVC Inner Sheath (Bedding):
Extruded PVC protecting the metallic screen and providing a stable base for armor.
7. SWA (Steel Wire Armor):
Galvanized round steel wires.
Protection against rodents, rocks, and mechanical impact for direct burial.
Also serves as a continuous earth path.
8. PVC Outer Sheath (Overseal):
Black UV-stabilized PVC – ST2 or ST7 (low smoke & halogen-free options available).
Printed with voltage, standard, length markers, and manufacturer code.
Why Choose This 110kV CU/XLPE/SWA Cable?
1.High Power Transfer Capacity:
Copper conductor combined with XLPE insulation allows up to 1000A+ continuous current (depending on installation) with minimal dielectric loss.
2. Robust Steel Wire Armor (SWA)
Withstands high pulling tension during installation (≥15 kN per core) and resists external compression in underground or submarine approaches.
3. IEC 60840 Certified
Fully type-tested for partial discharge (≤5pC at 2U₀), impulse voltage (550 kVp), and long-term aging. Suitable for 30+ year service life.
4. Zero Water Treeing (XLPE Grade)
Super-smooth insulation suppresses water tree growth, ensuring reliability in wet soil or high humidity tunnels.
5. Fire Safety Compliance
PVC outer sheath meets IEC 60332-1 for flame retardancy. LSZH (Low Smoke Zero Halogen) outer sheath optional for indoor/urban substations.
Typical Applications
| Property | Value |
|---|---|
| Max. Conductor DC Resistance (20°C) | 0.0151 Ω/km |
| XLPE Insulation Resistance | >10,000 MΩ·km |
| Capacitance | ~0.22 µF/km |
| Inductive Reactance (50Hz) | ~0.13 Ω/km |
| Short Circuit Current (1s, conductor) | 120 kA |
| Bending Radius (Installation) | 20 x outer diameter |
| Max Pulling Tension | 45 kN |
| Operating Temperature | -30°C to +90°C |
Note: Values vary with cross-section. Please consult our engineers for exact sizing.
Customization Options
Conductor size: 240mm² up to 2500mm² (copper or aluminum available).
Armor type: SWA (standard), double tape armor, or non-magnetic armor for single-core.
Outer sheath: PVC, LSZH (HFFR), or polyethylene (PE) for extra moisture barrier.
Fiber optic integration: Built-in OPGW or temperature sensing (DTS) fibers.
Section length: Continuous lengths up to 1500m per drum (depending on shipping).
Quality Assurance & Certification
| Certification | Status |
|---|---|
| IEC 60840 Type Tests | ✅ Passed (KEMA / CESI / China National Quality Supervision) |
| ISO 9001:2015 | ✅ Production facility certified |
| ISO 14001 | ✅ Environmental management |
| CE / UKCA | ✅ Available upon request (LV Directive via coordination) |
| RoHS | ✅ Compliant |
Factory Audit Ready: We provide full traceability from conductor drawing to HV partial discharge test.
Related Products You May Need
110kV Premoulded Slip-on Joints (IEC 60840) – For cable route splicing.
HV Outdoor Termination (Composite or Porcelain) – For substation gantry entry.
Cable Cleats (Short-circuit rated) – For SWA cable fixing per IEC 61914.
![]()
![]()
![]()
![]()