xlpe power cable
"
26/35 kV MV Stahlband Panzerkabel, 3 Kernpanzerkabel
26/35kV MV Armoured Electrical Cable Steel Tape Armoured STA 35kV Cu/XLPE/PVC/STA Construction Conductor: Circular compacted stranded Copper or aluminium Conductor screen: Extruded semi-conductive compound Insulation: XLPE Insulation screen: Extruded semi-conductive compound Metallic screen: Copper Wire Binder tape: non-hygroscopic material Inner covering(bedding): PVC Metallic armor: Galvanized steel tape Application Steel tape armored medium-voltage cables are designed for
Quadruplex Service Drop ABC Aerial Bundled Cables 3×70mm²+50mm² 3×95mm²+50mm²
Quadruplex Service Drop ABC Aerial Bundled Cables 3×70mm²+50mm² 3×95mm²+50mm² APPLICATION These cables are primarily used for three-phase power distribution from utility poles to residential/commercial service points, typically connecting pole-mounted transformers to weatherheads. The 3×70mm²+50mm² and 3×95mm²+50mm² configurations are designed for medium-to-high current loads, with the larger 95mm² variant supporting higher power demands. Key Applications: Residential
600V 1000V LV Niederspannungskabel für unterirdische, Niederspannungsleitungen
0.6/1kv LV Low Voltage Cable for Underground Use CU/XLPE/SWA/PVC Application Suitable for use in power distribution lines with rated voltage 0.6/1KV. For laying in shaft, water underground and large difference of level, able to bear external mechanical pressure and moderate pulling force. Construction Conductor:Circular, solid, compacted or sector shaped stranded Copper or aluminum Insulation:XLPE Filler: Non-hygroscopic material Inner sheath: PVC Armouring: Steel Wire Outer
XHWW-2 Aluminiumleiter MC-Kabel 3 Kern 4 Kern 600 V Aluminiumdraht
XHWW-2 Aluminium Conductor Cable 3 Core 4 Core MC cable Application TypeXHHW-2MC cable is suitable for use as branch,feeder and service power distribution.It is suitable for use in wet or dry locations at temperature not to exceed 90°C.If it should be directly buried in the earth,MC cable with PVC sheathis an optimal choice.Maximum voltage rating for XHHW-2 application is 600Volts . Construction Type XHHW-2 conductors which is constructed with 8000 Series Aluminium Alloy
Niederspannungs-Aerial ABC-Kabel AAC AAAC ACSR 4mm2-630mm2 600V 1000V
Low Voltage Aerial Bundled Cable AAC ABC AAAC ACSR 4mm2-630mm2 0.6/1kv Al/XLPE/PVC Application: Industrial Power Distribution : Factories, mining operations. Renewable Energy Systems : Solar farms, wind turbines. Public Infrastructure : Subways, tunnels (where low smoke and halogen-free properties are critical). Buildings : Commercial complexes requiring fire-safe cabling. Construction Advantages Cost Efficiency : Aluminum reduces material costs compared to copper. Safety :
Flammhemmendes Mittelspannungskabel 12/20kV N2XSH Einader Dreiader
Flame-retardant Medium Voltage Cable 12/20kV N2XSH Single Core Three Core APPLICATION Suitable for power supply lines with flame retardant requirements, such as urban underground power grids, power station outgoing lines, and internal power lines of industrial and mining enterprises. CONSTRUCTION C onductor: Tightly press circular conductor Conductor shield: S emi conductive shielding material (below 500mm ² ) Semi conductive tape+semi conductive shielding material (500mm ²
15/35kV AAC AAAC ACSR Freileitungsbündelkabel für Freileitungen
AAC AAAC ACSR Self Supporting Aerial Bundled Cable ABC Cable for Overhead Power Line APPLICATION AAC (All Aluminum Conductor) and AAAC (All Aluminum Alloy Conductor) are widely used in medium-voltage distribution networks (e.g., rural electrification, urban overhead lines) due to their lightweight and corrosion resistance. ACSR (Aluminum Conductor Steel Reinforced) is ideal for high-voltage transmission lines (e.g., 11kV-33kV) and long-distance power delivery, thanks to its
Drei-Kern-LSZH-Halogenkabel mit geringer Rauchbelastung mit Kupferleiter 600V Spannung
Three core Low Smoke Zero Halogen Cable Copper Conductor For 600V Voltage Application Low smoke zero halogen cables are becoming more popular in military applications, aircraft, railway and maritime. This is because in these areas it is often difficult to ventilate in the event of a fire.. Besides, Low smoke halogen free material is also widely used in high pressure underground tunnels or track marking lines in railway system. when using them, reduces the possibility of
8.7KV 15kV Mittelspannungskabel Niedrigrauch Halogen Null LSZH feuerfest
Low Smoke Zero Halogen Medium Voltage Cable LSZH Fire Resistant 8.7/15kV Application Urban Infrastructure :Underground power distribution networks in cities, tunnels, and subways where fire resistance and low smoke emission are critical for evacuation and rescue. Commercial and High-Rise Buildings :Main power supply systems, emergency circuits, and riser shafts in offices, hotels, and residential towers to comply with strict fire safety regulations. Public Transportation