Qualität Mittelspannung 26/35 KV Aluminiumleiterkabel Kupferband Schild PVC-Hülle Fabrik

Mittelspannung 26/35 KV Aluminiumleiterkabel Kupferband Schild PVC-Hülle

Medium Voltage 26/35 kV Aluminium Conductor Cable Copper Tape Shield PVC Sheath Application Suitable for urban underground power grids, power station outgoing lines, internal power supply lines of industrial and mining enterprises, etc. Construction Conductor Conductor Shiel Insulation Metal Shield Layer Filler Binder Tape Armouring Outer sheath Laying Method Pipe laying, trench laying, tunnel laying, vertical shaft and bridge laying, etc. Specification Specs mm² Conductor

Qualität Geschirmtes Instrumentenkabel 300/500V Geflechtschirm PVC-ummanteltes Computerkabel Fabrik

Geschirmtes Instrumentenkabel 300/500V Geflechtschirm PVC-ummanteltes Computerkabel

Shielded Instrument Cable 300/500V Braided Shield PVC Sheathed Computer Cable APPLICATION The cable is suitable for electronic computers and automation instruments with high anti-interference requirements for rated voltage of 500V and below CONSTRUCTION C onductor: The first or second type of copper conductor In s u lation: Low density polyethylene (LLDPE) Fill er (optional): Filling rope Separate shielding: Braided shielding (P) O verall shield: Braided shielding (P) Outer

Qualität Single Core HV High Voltage Power Cable  2XS(FL)2Y CU/XLPE/CWS/STA/PVC Fabrik

Single Core HV High Voltage Power Cable 2XS(FL)2Y CU/XLPE/CWS/STA/PVC

Single Core HV High Voltage Power Cable 2XS(FL)2Y CU/XLPE/CWS/STA/PVC APPLICATION Urban underground networks‌ (e.g., substation connections, industrial power distribution)‌ Harsh environments‌ requiring robust mechanical and chemical protection‌ CONSTRUCTION Conductor: Stranded circular or segmental (Milliken) compacted copper conductor Conductor shield: Semi-conductive shield Insulation: Cross-Linked Polyethylene(XLPE) Insulation shield: Semi-conductive shield Metal

Qualität Quadruplex Service Drop Aerial ABC-Kabel XLPE Isolierter Aluminium 4-Kernleiter Fabrik

Quadruplex Service Drop Aerial ABC-Kabel XLPE Isolierter Aluminium 4-Kernleiter

Quadruplex Service Drop Aerial Bundled ABC Cable XLPE Insulated Aluminium 4 Core Conductor APPLICATION 1 phase:t o supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 1000 volts or lower at a conductor temperature of 75℃ maximum 2 phase: t o supply power from the utility ’ s lines to the consumer ’ s weatherhead. For service at 1000 volts or less (phase to phase) at a conductor temperature of 75℃ maximum for

Qualität Gesamtschild-Instrumentkabel mit 2 Paaren 1,5 mm2 Draht gepanzerter Gesamttyp Fabrik

Gesamtschild-Instrumentkabel mit 2 Paaren 1,5 mm2 Draht gepanzerter Gesamttyp

Overall Shield Instrument Cable with 2 Pairs 1.5mm2 Wire Armoured Overall Type APPLICATION Overall Shield Instrument Cable with 2 Pairs 1.5mm² Wire Armoured Overall Type is designed for industrial instrumentation and control systems where electromagnetic interference (EMI) protection and mechanical durability are critical. Industrial Automation‌: Used in control circuits for machinery, robots, and power generation systems to ensure signal integrity amid high EMI.Marine

Qualität Drei-Kern-LSZH-Halogenkabel mit geringer Rauchbelastung mit Kupferleiter 600V Spannung Fabrik

Drei-Kern-LSZH-Halogenkabel mit geringer Rauchbelastung mit Kupferleiter 600V Spannung

Three core Low Smoke Zero Halogen Cable Copper Conductor For 600V Voltage Application Low smoke zero halogen cables are becoming more popular in military applications, aircraft, railway and maritime. This is because in these areas it is often difficult to ventilate in the event of a fire.. Besides, Low smoke halogen free material is also widely used in high pressure underground tunnels or track marking lines in railway system. when using them, reduces the possibility of

Qualität 6 8 10 Gauge AWG Größe Aluminium Leiter Stromkabel AA8000 XLPE Isolierung XHHW XHHW-2 Fabrik

6 8 10 Gauge AWG Größe Aluminium Leiter Stromkabel AA8000 XLPE Isolierung XHHW XHHW-2

6 8 10 Gauge AWG Size Aluminum Conductor Cable AA8000 XLPE Insulation XHHW XHHW-2 Application XHHW-2 is primarily used in house construction, conduit, or recognized raceways for services, feeders, and branch circuit wiring in wet or dry locations, at temperatures not to exceed 90°C. Voltage rating is 600V. This product is designed to be installed without the application of pulling lubricant. . Construction Conductor: Aluminum Alloy Insulation: 120℃ XLPE/XLPO Jacket: XLPE, PVC

Qualität STA Geschirmtes Instrumentenkabel, flammhemmendes Computerkabel Fabrik

STA Geschirmtes Instrumentenkabel, flammhemmendes Computerkabel

STA Shielded Instrument Cable Flame Retardant Computer Cable APPLICATION Industrial automation systems (PLC, DCS, SCADA) Power plants, chemical plants, and mining facilities Data centers and computer rooms requiring EMI shielding Underground or hazardous locations requiring flame retardancy CONSTRUCTION C onductor: The first or second type of copper conductor In s u lation: Low density polyethylene (LLDPE) Fill er (optional): Filling rope Separate shielding: Braided shielding

Qualität 660/1100V Niederspannungskabel Vvg Vvgng Vvgng-Frls Kupfer-Stromkabel EAC-zertifiziertes Kabel Fabrik

660/1100V Niederspannungskabel Vvg Vvgng Vvgng-Frls Kupfer-Stromkabel EAC-zertifiziertes Kabel

660/1100V Low Voltage Cable Vvg Vvgng Vvgng-Frls Copper Power Cable EAC Certified Cable APPLICATION Construction, Underground, Industrial, Power Station CONSTRUCTION Conductor: Class 2 stranded Copper conductor Insulation: Cross-Linked Polyethylene(XLPE) Outer sheath: Polyvinyl chloride (PVC) CHARACTERICSTIC Voltage Rating Uo/U: 0.6/1kV M aximum system voltage: 12kV Maximum operating temperature of conductor: +90℃ Operating ambient temperature: -20℃~+45℃ Cable laying